These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
108 related articles for article (PubMed ID: 8106585)
1. High-performance liquid chromatographic method for the routine determination of diclofenac and its hydroxy and methoxy metabolites from in vitro systems. Schmitz G; Lepper H; Estler CJ J Chromatogr; 1993 Oct; 620(1):158-63. PubMed ID: 8106585 [TBL] [Abstract][Full Text] [Related]
2. Determination of trimethoprim and its oxidative metabolites in cell culture media and microsomal incubation mixtures by high-performance liquid chromatography. van 't Klooster GA; Kolker HJ; Woutersen-van Nijnanten FM; Noordhoek J; van Miert AS J Chromatogr; 1992 Sep; 579(2):354-60. PubMed ID: 1429985 [TBL] [Abstract][Full Text] [Related]
3. Extractionless high-performance liquid chromatographic method for the determination of diclofenac in human plasma and urine. Avgerinos A; Karidas T; Malamataris S J Chromatogr; 1993 Sep; 619(2):324-9. PubMed ID: 8263107 [TBL] [Abstract][Full Text] [Related]
4. Determination of CYP2C9-catalyzed diclofenac 4'-hydroxylation by high-performance liquid chromatography. Crespi CL; Chang TK; Waxman DJ Methods Mol Biol; 2006; 320():109-13. PubMed ID: 16719380 [TBL] [Abstract][Full Text] [Related]
5. An automated method for the determination of diclofenac sodium in human plasma. Brunner LA; Luders RC J Chromatogr Sci; 1991 Jul; 29(7):287-91. PubMed ID: 1869614 [TBL] [Abstract][Full Text] [Related]
6. High-performance liquid chromatographic determination of diclofenac and its monohydroxylated metabolites in biological fluids. Godbillon J; Gauron S; Metayer JP J Chromatogr; 1985 Feb; 338(1):151-9. PubMed ID: 4019641 [TBL] [Abstract][Full Text] [Related]
7. Efficient high performance liquid chromatograph/ultraviolet method for determination of diclofenac and 4'-hydroxydiclofenac in rat serum. Kaphalia L; Kaphalia BS; Kumar S; Kanz MF; Treinen-Moslen M J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Jan; 830(2):231-7. PubMed ID: 16301007 [TBL] [Abstract][Full Text] [Related]
8. Validation of a novel in vitro assay using ultra performance liquid chromatography-mass spectrometry (UPLC/MS) to detect and quantify hydroxylated metabolites of BDE-99 in rat liver microsomes. Erratico CA; Szeitz A; Bandiera SM J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Jun; 878(19):1562-8. PubMed ID: 20451473 [TBL] [Abstract][Full Text] [Related]
9. Highly sensitive and specific high-performance liquid chromatographic analysis of 7-hydroxywarfarin, a marker for human cytochrome P-4502C9 activity. Lang D; Böcker R J Chromatogr B Biomed Appl; 1995 Oct; 672(2):305-9. PubMed ID: 8581139 [TBL] [Abstract][Full Text] [Related]
10. Detection of triazolam and its hydroxy metabolites in rat hair by reversed-phase liquid chromatography with electrospray ionization mass spectrometry. Toyoóka T; Kanbori M; Kumaki Y; Oe T; Miyahara T; Nakahara Y J Anal Toxicol; 2000 Apr; 24(3):194-201. PubMed ID: 10774539 [TBL] [Abstract][Full Text] [Related]
11. High-performance liquid chromatographic assay for antiinflammatory agents diclofenac and flurbiprofen in ocular fluids. Riegel M; Ellis PP J Chromatogr B Biomed Appl; 1994 Mar; 654(1):140-5. PubMed ID: 8004236 [TBL] [Abstract][Full Text] [Related]
12. Simultaneous determination of testosterone metabolites in liver microsomes using column-switching semi-microcolumn high-performance liquid chromatography. Tachibana S; Tanaka M Anal Biochem; 2001 Aug; 295(2):248-56. PubMed ID: 11488629 [TBL] [Abstract][Full Text] [Related]
13. Determination of diclofenac in plasma by high-performance liquid chromatography with electrochemical detection. Chmielewska A; Konieczna L; Plenis A; Bieniecki M; Lamparczyk H Biomed Chromatogr; 2006 Jan; 20(1):119-24. PubMed ID: 16010692 [TBL] [Abstract][Full Text] [Related]
14. Simultaneous determination of diclofenac potassium and drotaverine hydrochloride in human plasma using reversed-phase high-performance liquid chromatography. Dahivelkar PP; Bhoir SI; Bari SB; Surana SJ; Bhagwat AM J Chromatogr Sci; 2012 Sep; 50(8):694-701. PubMed ID: 22573800 [TBL] [Abstract][Full Text] [Related]
15. Application of HPLC with silica-phase and reversed-phase eluents for the determination of clomipramine and demethylated and 8-hydroxylated metabolites. Coudoré F; Hourcade F; Molinier-Manoukian C; Eschalier A; Lavarenne J J Anal Toxicol; 1996; 20(2):101-5. PubMed ID: 8868400 [TBL] [Abstract][Full Text] [Related]
16. Improved high-performance liquid chromatographic procedure for the separation and quantification of hydroxytestosterone metabolites. Purdon MP; Lehman-McKeeman LD J Pharmacol Toxicol Methods; 1997 Mar; 37(2):67-73. PubMed ID: 9174981 [TBL] [Abstract][Full Text] [Related]
17. HPLC determination of midazolam and its three hydroxy metabolites in perfusion medium and plasma from rats. Jurica J; Dostálek M; Konecný J; Glatz Z; Hadasová E; Tomandl J J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):571-7. PubMed ID: 17350905 [TBL] [Abstract][Full Text] [Related]
18. Liquid chromatographic determination of diclofenac in human synovial fluid. Roskar R; Kmetec V J Chromatogr B Analyt Technol Biomed Life Sci; 2003 May; 788(1):57-64. PubMed ID: 12668071 [TBL] [Abstract][Full Text] [Related]
19. Simultaneous determination of diclofenac and oxybuprocaine in human aqueous humor with HPLC and electrochemical detection. Kuhlmann O; Stoldt G; Struck HG; Krauss GJ J Pharm Biomed Anal; 1998 Sep; 17(8):1351-6. PubMed ID: 9800654 [TBL] [Abstract][Full Text] [Related]
20. Comparison of UV and tandem mass spectrometric detection for the high-performance liquid chromatographic determination of diclofenac in microdialysis samples. Mayer BX; Namiranian K; Dehghanyar P; Stroh R; Mascher H; Müller M J Pharm Biomed Anal; 2003 Nov; 33(4):745-54. PubMed ID: 14623601 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]