132 related articles for article (PubMed ID: 8106597)
1. Simultaneous determination of glucose and 1-deoxyglucose in serum by anion-exchange chromatography with an immobilized pyranose oxidase reactor.
Kiba N; Goto Y; Furusawa M
J Chromatogr; 1993 Oct; 620(1):9-13. PubMed ID: 8106597
[TBL] [Abstract][Full Text] [Related]
2. Post-column enzyme reactors for chemiluminometric detection of glucose, 1,5-anhydroglucitol and 3-hydroxybutyrate in an anion-exchange chromatographic system.
Kiba N; Saegusa K; Furusawa M
J Chromatogr B Biomed Sci Appl; 1997 Feb; 689(2):393-8. PubMed ID: 9080327
[TBL] [Abstract][Full Text] [Related]
3. On-line chemiluminescence assay using FIA and fiber optics for urinary and blood glucose.
Cattaneo MV; Luong JH
Enzyme Microb Technol; 1993 May; 15(5):424-8. PubMed ID: 7763630
[TBL] [Abstract][Full Text] [Related]
4. Determination of hydrogen peroxide by micro-flow injection-chemiluminescence using a coupled flow cell reactor chemiluminometer.
Nozaki O; Kawamoto H
Luminescence; 2000; 15(3):137-42. PubMed ID: 10862141
[TBL] [Abstract][Full Text] [Related]
5. Comparison of micro-enzymatic and high-performance liquid chromatographic methods for the assay of serum 1,5-anhydroglucitol.
Chusney GD; Philippa M; Pickup JC
Clin Chim Acta; 1995 Feb; 235(1):91-9. PubMed ID: 7634494
[TBL] [Abstract][Full Text] [Related]
6. Highly sensitive flow injection analysis of glucose and uric acid in serum using an immobilized enzyme column and chemiluminescence.
Tabata M; Fukunaga C; Ohyabu M; Murachi T
J Appl Biochem; 1984 Aug; 6(4):251-8. PubMed ID: 6520074
[TBL] [Abstract][Full Text] [Related]
7. A chemiluminescence automatic analyser for the measurement of biological compounds.
Tabata M; Totani M; Murachi T
J Biolumin Chemilumin; 1989 Jul; 4(1):523-30. PubMed ID: 2801237
[TBL] [Abstract][Full Text] [Related]
8. Determination of 1,5-anhydroglucitol in urine by high performance liquid chromatography and an enzyme sensor.
Tajima S; Hashiba M; Suzuki T; Akanuma H; Yabuuchi M
Biomed Chromatogr; 1993; 7(1):41-4. PubMed ID: 8431679
[TBL] [Abstract][Full Text] [Related]
9. Postcolumn co-immobilized leucine dehydrogenase-NADH oxidase reactor for the determination of branched-chain amino acids by high-performance liquid chromatography with chemiluminescence detection.
Kiba N; Oyama Y; Kato A; Furusawa M
J Chromatogr A; 1996 Feb; 724(1-2):355-7. PubMed ID: 8819797
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous determination of 2-deoxy-D-glucose and D-glucose in rat serum by high-performance liquid chromatography with post-column fluorescence derivatization.
Umegae Y; Nohta H; Ohkura Y
Chem Pharm Bull (Tokyo); 1990 Apr; 38(4):963-5. PubMed ID: 2379291
[TBL] [Abstract][Full Text] [Related]
11. Fully enzymatic method for determining 1,5-anhydro-D-glucitol in serum.
Fukumura Y; Tajima S; Oshitani S; Ushijima Y; Kobayashi I; Hara F; Yamamoto S; Yabuuchi M
Clin Chem; 1994 Nov; 40(11 Pt 1):2013-6. PubMed ID: 7955370
[TBL] [Abstract][Full Text] [Related]
12. Dissolved oxygen determination by electrocatalysed chemiluminescence with in-line solid phase media.
Atwater JE; DeHart J; Wheeler RR
J Biolumin Chemilumin; 1998; 13(3):125-30. PubMed ID: 9693979
[TBL] [Abstract][Full Text] [Related]
13. Determination of inorganic phosphate by flow injection method with immobilized enzymes and chemiluminescence detection.
Kawasaki H; Sato K; Ogawa J; Hasegawa Y; Yuki H
Anal Biochem; 1989 Nov; 182(2):366-70. PubMed ID: 2514613
[TBL] [Abstract][Full Text] [Related]
14. Inhibition of the system luminol-H2O2-Fe(CN)6(3)-chemiluminescence by the Mn(II) indirect determination of isoniazid in a pharmaceutical formulation.
Gregorio Alapont A; Aurechia Giménez E; Lahuerta Zamora L; Martínez Calatayud J
J Biolumin Chemilumin; 1998; 13(3):131-7. PubMed ID: 9693980
[TBL] [Abstract][Full Text] [Related]
15. Fully automated flow-injection system for quantifying 1,5-anhydro-D-glucitol in serum.
Tanabe T; Umegae Y; Koyashiki Y; Kato Y; Fukahori K; Tajima S; Yabuuchi M
Clin Chem; 1994 Nov; 40(11 Pt 1):2006-12. PubMed ID: 7955369
[TBL] [Abstract][Full Text] [Related]
16. [Flow injection analysis for determination of choline-containing phospholipids by luminol chemiluminescence].
Matsubara C; Ishii K; Takamura K
Yakugaku Zasshi; 1992 Jan; 112(1):50-5. PubMed ID: 1578343
[TBL] [Abstract][Full Text] [Related]
17. On-line determination of glucose concentration throughout animal cell cultures based on chemiluminescent detection of hydrogen peroxide coupled with flow-injection analysis.
Huang YL; Li SY; Dremel BA; Bilitewski U; Schmid RD
J Biotechnol; 1991 Apr; 18(1-2):161-72. PubMed ID: 1367102
[TBL] [Abstract][Full Text] [Related]
18. Determination of serum glucose by horseradish peroxidase-catalysed imidazole chemiluminescence coupled to a micro-flow-injection system.
Nozaki O; Munesue M; Kawamoto H
Luminescence; 2007; 22(5):401-6. PubMed ID: 17624864
[TBL] [Abstract][Full Text] [Related]
19. Determination of sulphite using an immobilized enzyme with flow injection chemiluminescence detection.
Yaqoob M; Nabi A; Waseem A; Masoom-Yasinzai M
Luminescence; 2004; 19(1):26-30. PubMed ID: 14981643
[TBL] [Abstract][Full Text] [Related]
20. Flow-through micro sensor using immobilized peroxidase with chemiluminometric FIA system for determining hydrogen peroxide.
Kiba N; Tokizawa T; Kato S; Tachibana M; Tani K; Koizumi H; Edo M; Yonezawa E
Anal Sci; 2003 Jun; 19(6):823-7. PubMed ID: 12834219
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]