These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 8106891)

  • 1. A novel sensor for routine continuous spirometry of intubated patients.
    Meriläinen P; Hänninen H; Tuomaala L
    J Clin Monit; 1993 Nov; 9(5):374-80. PubMed ID: 8106891
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Monitoring airway gas in pediatric anesthesia: an experimental model for endotracheal gas measurement].
    Calvo Vecino JM; Abad Gurumeta A; Gil Lapetra C; Muñoz Velázquez MF; Pérez Gallardo A; Gilsanz Rodríguez F
    Rev Esp Anestesiol Reanim; 2008 Jan; 55(1):13-20. PubMed ID: 18333381
    [TBL] [Abstract][Full Text] [Related]  

  • 3. AANA journal course: new technologies in anesthesia: update for nurse anesthetists--monitoring ventilation and compliance with Side Stream Spirometry.
    Huffman LM
    AANA J; 1991 Jun; 59(3):249-59. PubMed ID: 1950403
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of pressure/volume loops based on intratracheal pressure measurements during dynamic conditions.
    Kárason S; Søndergaard S; Lundin S; Wiklund J; Stenqvist O
    Acta Anaesthesiol Scand; 2000 May; 44(5):571-7. PubMed ID: 10786745
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved flow and pressure capabilities of the Datex-Ohmeda SmartVent anesthesia ventilator.
    Katz JA; Kallet RH; Alonso JA; Marks JD
    J Clin Anesth; 2000 Feb; 12(1):40-7. PubMed ID: 10773507
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Performance studies of 6 new anesthesia ventilators: bench tests].
    Jaber S; Langlais N; Fumagalli B; Cornec S; Beydon L; Harf A; Brochard L
    Ann Fr Anesth Reanim; 2000 Jan; 19(1):16-22. PubMed ID: 10751951
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of a heat and moisture exchange filter on sidestream spirometry in critically ill patients.
    Puolakka JJ; Jousela IT
    Int J Clin Monit Comput; 1994 Nov; 11(4):217-22. PubMed ID: 7738415
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The most proximal and accurate site for sampling end-tidal CO2 in infants.
    Halpern L; Bissonnette B
    Can J Anaesth; 1994 Oct; 41(10):984-90. PubMed ID: 8001218
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Continuous monitoring of the flow-volume loops and compliance during anesthesia.
    Bardoczky GI; d'Hollander A
    J Clin Monit; 1992 Jul; 8(3):251-2. PubMed ID: 1494935
    [No Abstract]   [Full Text] [Related]  

  • 10. Tracheal tube resistance and airway and alveolar pressures during mechanical ventilation in the neonate.
    Tipping TR; Sykes MK
    Anaesthesia; 1991 Jul; 46(7):565-9. PubMed ID: 1862898
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Detection of partial obstructions of the endotracheal tube].
    Schumann S; Kessler V; Mols G; Geiger K; Guttmann J
    Biomed Tech (Berl); 1998; 43 Suppl():308-9. PubMed ID: 9859374
    [No Abstract]   [Full Text] [Related]  

  • 12. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system.
    Banner MJ; Blanch PB; Kirby RR
    Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of three transportable multigas anesthetic monitors: the Bruel & Kjaer Anesthetic Gas Monitor 1304, the Datex Capnomac Ultima, and the Nellcor N-2500.
    Nielsen J; Kann T; Moller JT
    J Clin Monit; 1993 Apr; 9(2):91-8. PubMed ID: 8166778
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The esophageal-tracheal combitube resistance and ventilatory pressures.
    Gaitini LA; Vaida SJ; Mostafa S; Yanovski B; Ben-David B; Benumof JL
    J Clin Anesth; 2005 Feb; 17(1):26-9. PubMed ID: 15721726
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy and cross-sensitivity of 10 different anesthetic gas monitors.
    Walder B; Lauber R; Zbinden AM
    J Clin Monit; 1993 Nov; 9(5):364-73. PubMed ID: 8106890
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation in animals of a system to estimate tracheal pressure from the endotracheal tube cuff.
    Wilder NA; Orr J; Westenskow D
    J Clin Monit; 1996 Jan; 12(1):11-6. PubMed ID: 8732811
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of respiratory system impedance on volume and pressure delivered at the Y piece in ventilated infants.
    Nève V; Leclerc F; Noizet O; Vernoux S; Leteurtre S; Forget P; Sadik A; Riou Y
    Pediatr Crit Care Med; 2003 Oct; 4(4):418-25. PubMed ID: 14525635
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume.
    Al-Majed SI; Thompson JE; Watson KF; Randolph AG
    Crit Care; 2004 Dec; 8(6):R398-402. PubMed ID: 15566583
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Newton valve revisited: an in-vitro study of ventilator circuit dead space.
    Wongprasartsuk P; Mason DG
    Paediatr Anaesth; 2000; 10(4):389-93. PubMed ID: 10886695
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Absence of a capnogram after positive end-expiratory pressure.
    Bowie JR; Smith RA; Downs JB
    J Clin Monit; 1993 Apr; 9(2):78-80. PubMed ID: 8478652
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.