These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
127 related articles for article (PubMed ID: 8110099)
1. Body composition analysis by dual energy X-ray absorptiometry compared to chemical analysis of fat, lean and bone mass in small piglets. Brunton JA; Bayley HS; Atkinson SA Basic Life Sci; 1993; 60():157-60. PubMed ID: 8110099 [No Abstract] [Full Text] [Related]
2. Validation and application of dual-energy x-ray absorptiometry to measure bone mass and body composition in small infants. Brunton JA; Bayley HS; Atkinson SA Am J Clin Nutr; 1993 Dec; 58(6):839-45. PubMed ID: 8249864 [TBL] [Abstract][Full Text] [Related]
3. Reference values of body composition obtained by dual energy X-ray absorptiometry in preterm and term neonates. Rigo J; Nyamugabo K; Picaud JC; Gerard P; Pieltain C; De Curtis M J Pediatr Gastroenterol Nutr; 1998 Aug; 27(2):184-90. PubMed ID: 9702651 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of dual-energy X-ray absorptiometry for body-composition assessment in piglets and term human neonates. Picaud JC; Rigo J; Nyamugabo K; Milet J; Senterre J Am J Clin Nutr; 1996 Feb; 63(2):157-63. PubMed ID: 8561054 [TBL] [Abstract][Full Text] [Related]
5. Performance of dual-energy x-ray absorptiometry in evaluating bone, lean body mass, and fat in pediatric subjects. Chan GM J Bone Miner Res; 1992 Apr; 7(4):369-74. PubMed ID: 1609625 [TBL] [Abstract][Full Text] [Related]
6. Use of fan beam dual energy x-ray absorptiometry to measure body composition of piglets. Koo WW; Hammami M; Hockman EM J Nutr; 2002 Jun; 132(6):1380-3. PubMed ID: 12042462 [TBL] [Abstract][Full Text] [Related]
7. An evaluation of dual-energy X-Ray absorptiometry and underwater weighing to estimate body composition by means of carcass analysis in piglets. Elowsson P; Forslund AH; Mallmin H; Feuk U; Hansson I; Carlsten J J Nutr; 1998 Sep; 128(9):1543-9. PubMed ID: 9732317 [TBL] [Abstract][Full Text] [Related]
9. Improvement in the accuracy of dual energy x-ray absorptiometry for whole body and regional analysis of body composition: validation using piglets and methodologic considerations in infants. Brunton JA; Weiler HA; Atkinson SA Pediatr Res; 1997 Apr; 41(4 Pt 1):590-6. PubMed ID: 9098865 [TBL] [Abstract][Full Text] [Related]
10. Dual energy X-ray absorptiometry measurements in small subjects: conditions affecting clinical measurements. Koo WW; Hockman EM; Hammami M J Am Coll Nutr; 2004 Jun; 23(3):212-9. PubMed ID: 15190045 [TBL] [Abstract][Full Text] [Related]
11. Accuracy of dual-energy X-ray absorptiometry in infant scans. An assessment using anthropomorphic phantoms. Shypailo RJ; Ellis KJ Ann N Y Acad Sci; 2000 May; 904():98-100. PubMed ID: 10865716 [No Abstract] [Full Text] [Related]
12. Technical considerations for fan-beam dual-energy x-ray absorptiometry body composition measurements in pediatric studies. Hammami M; Koo WW; Hockman EM JPEN J Parenter Enteral Nutr; 2004; 28(5):328-33. PubMed ID: 15449572 [TBL] [Abstract][Full Text] [Related]
13. Comparison of two phantoms for body composition with dual-energy X-ray absorptiometry. Diessel E; Shepherd JA; Fuerst T; Gonzalez M; Genant HK; Carew B; Looker A Ann N Y Acad Sci; 2000 May; 904():107-10. PubMed ID: 10865719 [No Abstract] [Full Text] [Related]
14. Bone status and body fat of healthy newborn Caucasian infants. Chan GM; Zhang H Basic Life Sci; 1993; 60():161-4. PubMed ID: 8110100 [No Abstract] [Full Text] [Related]
15. Dual-energy X-ray absorptiometry measurements of the body composition of pigs of 90- to 130-kilograms body weight. Mitchell AD; Scholz AM; Pursel VG Ann N Y Acad Sci; 2000 May; 904():85-93. PubMed ID: 10865714 [TBL] [Abstract][Full Text] [Related]
16. Assessment of regional body composition changes by dual-energy X-ray absorptiometry. Friedl KE; Vogel JA; Marchitelli LJ; Kubel SL Basic Life Sci; 1993; 60():99-103. PubMed ID: 8110176 [No Abstract] [Full Text] [Related]
17. Validation of estimates of lean tissue mass made by dual-energy X-ray absorptiometry. Humphries IR; Hua V; Ban L; Gaskin KJ; Howman-Giles R Ann N Y Acad Sci; 2000 May; 904():104-6. PubMed ID: 10865718 [No Abstract] [Full Text] [Related]
18. Accuracy of measurements of total-body soft-tissue composition by dual energy X-ray absorptiometry in vivo. Svendsen OL; Haarbo J; Hassager C; Christriansen C Basic Life Sci; 1993; 60():381-3. PubMed ID: 8110156 [No Abstract] [Full Text] [Related]
19. Assessing the accuracy of measurements obtained by dual-energy X-ray absorptiometry on pig carcasses and primal cuts. Kipper M; Marcoux M; Andretta I; Pomar C Meat Sci; 2019 Feb; 148():79-87. PubMed ID: 30340164 [TBL] [Abstract][Full Text] [Related]
20. Body composition analysis of small pigs by dual-energy x-ray absorptiometry. Mitchell AD; Scholz AM; Conway JM J Anim Sci; 1998 Sep; 76(9):2392-8. PubMed ID: 9781495 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]