These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 8110099)

  • 21. Repeatability and reproducibility of measurements obtained by dual-energy X-ray absorptiometry on pig carcasses.
    Kipper M; Marcoux M; Andretta I; Pomar C
    J Anim Sci; 2018 May; 96(5):2027-2037. PubMed ID: 29722809
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Fat-free mass and percent body fat assessments by dual-energy X-ray absorptiometry, densitometry and total body water.
    Wellens R; Roche AF; Guo S; Chumlea WC; Siervogel RM
    Basic Life Sci; 1993; 60():71-4. PubMed ID: 8110167
    [No Abstract]   [Full Text] [Related]  

  • 23. Total bone mineral content and body composition by x-ray densitometry in newborns.
    Venkataraman PS; Ahluwalia BW
    Pediatrics; 1992 Nov; 90(5):767-70. PubMed ID: 1408552
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Reproducibility of dual-energy x-ray absorptiometry.
    Chilibeck P; Calder A; Sale DG; Webber C
    Can Assoc Radiol J; 1994 Aug; 45(4):297-302. PubMed ID: 8062121
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of dual-energy X-Ray absorptiometry for body-composition assessment in rats.
    Bertin E; Ruiz JC; Mourot J; Peiniau P; Portha B
    J Nutr; 1998 Sep; 128(9):1550-4. PubMed ID: 9732318
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Dual photon absorptiometry, dual energy X-ray absorptiometry for analysis of body fat mass].
    Itabashi A
    Nihon Rinsho; 1995 Jun; 53 Suppl():174-8. PubMed ID: 7563689
    [No Abstract]   [Full Text] [Related]  

  • 27. Total body dual X-ray absorptiometry is a good measure of both fat mass and fat-free mass in liver cirrhosis compared to "gold-standard" techniques. Melbourne Liver Group.
    Strauss BJ; Gibson PR; Stroud DB; Borovnicar DJ; Xiong DW; Keogh J
    Ann N Y Acad Sci; 2000 May; 904():55-62. PubMed ID: 10865710
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Technical note: Prediction of chemical rib section composition by dual energy X-ray absorptiometry in Zebu beef cattle.
    Prados LF; Zanetti D; Amaral PM; Mariz LD; Sathler DF; Filho SC; Silva FF; Silva BC; Pacheco MC; Alhadas HM; Chizzotti ML
    J Anim Sci; 2016 Jun; 94(6):2479-84. PubMed ID: 27285924
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Usefulness of dual energy X-ray absorptiometry for body composition measurement in adult dogs.
    Toll PW; Gross KL; Berryhill SA; Jewell DE
    J Nutr; 1994 Dec; 124(12 Suppl):2601S-2603S. PubMed ID: 7996247
    [No Abstract]   [Full Text] [Related]  

  • 30. Accuracy of DXA-based body composition measurements for pediatric studies.
    Ellis KJ; Shypailo RJ; Pratt JA; Pond WG
    Basic Life Sci; 1993; 60():153-6. PubMed ID: 8110098
    [No Abstract]   [Full Text] [Related]  

  • 31. Body composition by DXA: tried and true?
    Kohrt WM
    Med Sci Sports Exerc; 1995 Oct; 27(10):1349-53. PubMed ID: 8531604
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparisons between fat measurements by dual-energy X-ray absorptiometry, magnetic resonance imaging and underwater weighing.
    Tothill P; Han TS; Avenell A; McNeill G; Reid DM
    Appl Radiat Isot; 1998; 49(5-6):457-9. PubMed ID: 9569514
    [No Abstract]   [Full Text] [Related]  

  • 33. Assessment of whole-body composition with dual-energy x-ray absorptiometry.
    Slosman DO; Casez JP; Pichard C; Rochat T; Fery F; Rizzoli R; Bonjour JP; Morabia A; Donath A
    Radiology; 1992 Nov; 185(2):593-8. PubMed ID: 1410379
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Analysis of dual energy X-ray absorptiometry whole body results in children, adolescents and young adults.
    Braillon PM; Cochat P
    Appl Radiat Isot; 1998; 49(5-6):623-4. PubMed ID: 9606087
    [No Abstract]   [Full Text] [Related]  

  • 35. Measurement of lean body mass with dual energy X-Ray absorptiometry in dialysis patients and its pitfalls.
    Numata M; Yamamoto H; Nakayama M; Kubo H; Takahashi H; Osaka N; Kawaguchi Y; Hosoya T
    Nephron; 1999 Sep; 83(1):91-2. PubMed ID: 10461043
    [No Abstract]   [Full Text] [Related]  

  • 36. Body composition and bone mass in post-menopausal women.
    Compston JE; Bhambhani M; Laskey MA; Murphy S; Khaw KT
    Clin Endocrinol (Oxf); 1992 Nov; 37(5):426-31. PubMed ID: 1486693
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Validation of a dual energy X-ray absorptiometer: measurement of bone mass and soft tissue composition.
    Madsen OR; Jensen JE; Sørensen OH
    Eur J Appl Physiol Occup Physiol; 1997; 75(6):554-8. PubMed ID: 9202954
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Body composition of neonates from fan beam dual energy X-ray absorptiometry measurement.
    Hammami M; Koo WW; Hockman EM
    JPEN J Parenter Enteral Nutr; 2003; 27(6):423-6. PubMed ID: 14621124
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Validation of dual energy X-ray absorptiometry (DXA) by comparison with chemical analysis of dogs and cats.
    Speakman JR; Booles D; Butterwick R
    Int J Obes Relat Metab Disord; 2001 Mar; 25(3):439-47. PubMed ID: 11319644
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A comparison between neutron activation and dual energy X-ray absorptiometry for the measurement of body fat.
    Ryde SJ; Laskey MA; Morgan WD; Compston JE
    Basic Life Sci; 1993; 60():367-70. PubMed ID: 8110153
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.