These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
74 related articles for article (PubMed ID: 8116393)
1. Clinical, radiological and human histological experience with hydroxyapatite coatings in orthopaedic surgery. Geesink RG Acta Orthop Belg; 1993; 59 Suppl 1():160-4. PubMed ID: 8116393 [TBL] [Abstract][Full Text] [Related]
2. [Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration]. Landor I; Vavrík P; Jahoda D; Pokorný D; Ballay R; Sosna A Acta Chir Orthop Traumatol Cech; 2009 Jun; 76(3):172-8. PubMed ID: 19595277 [TBL] [Abstract][Full Text] [Related]
3. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry. Paulsen A; Pedersen AB; Johnsen SP; Riis A; Lucht U; Overgaard S Acta Orthop; 2007 Oct; 78(5):622-8. PubMed ID: 17966021 [TBL] [Abstract][Full Text] [Related]
5. Clinical total hip replacement with hydroxyapatite from 1984 to 1991. Door LD Semin Arthroplasty; 1991 Oct; 2(4):289-94. PubMed ID: 10149616 [TBL] [Abstract][Full Text] [Related]
6. [Long-term results of the Schenker cementless femoral component]. Dzupa V; Cech O; Sesták M; Klézl Z Acta Chir Orthop Traumatol Cech; 2004; 71(2):93-100. PubMed ID: 15151096 [TBL] [Abstract][Full Text] [Related]
7. Rationale and clinical application of hydroxyapatite coatings in pressfit total hip arthroplasty. Jaffe WL; Scott DF Semin Arthroplasty; 1993 Jul; 4(3):159-66. PubMed ID: 10146282 [TBL] [Abstract][Full Text] [Related]
8. Hydroxyapatite-coated total hip prostheses. Two-year clinical and roentgenographic results of 100 cases. Geesink RG Clin Orthop Relat Res; 1990 Dec; (261):39-58. PubMed ID: 2245562 [TBL] [Abstract][Full Text] [Related]
9. Early clinical results with the hydroxyapatite-coated porous LSF Total Hip System. Cook SD; Enis J; Armstrong D; Lisecki E Dent Clin North Am; 1992 Jan; 36(1):247-55. PubMed ID: 1310657 [TBL] [Abstract][Full Text] [Related]
10. [Biological reaction to a hydroxyapatite-covered prosthesis]. Maquet P Acta Orthop Belg; 1993; 59 Suppl 1():326-8. PubMed ID: 8116421 [No Abstract] [Full Text] [Related]
11. Clinical results with the hydroxyapatite-coated Omnifit hip stem. Manley MT; Koch R Dent Clin North Am; 1992 Jan; 36(1):257-62. PubMed ID: 1310658 [TBL] [Abstract][Full Text] [Related]
12. Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components. Coathup MJ; Blackburn J; Goodship AE; Cunningham JL; Smith T; Blunn GW Biomaterials; 2005 Jul; 26(19):4161-9. PubMed ID: 15664643 [TBL] [Abstract][Full Text] [Related]
13. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty]. Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572 [TBL] [Abstract][Full Text] [Related]
14. Hot isostatic pressing-processed hydroxyapatite-coated titanium implants: light microscopic and scanning electron microscopy investigations. Wie H; Herø H; Solheim T Int J Oral Maxillofac Implants; 1998; 13(6):837-44. PubMed ID: 9857595 [TBL] [Abstract][Full Text] [Related]
15. The effect of three different calcium phosphate implant coatings on bone deposition and coating resorption: a long-term histological study in sheep. Schopper C; Moser D; Goriwoda W; Ziya-Ghazvini F; Spassova E; Lagogiannis G; Auterith A; Ewers R Clin Oral Implants Res; 2005 Jun; 16(3):357-68. PubMed ID: 15877757 [TBL] [Abstract][Full Text] [Related]
16. [Histological analysis of the bone/prosthesis interface in man after implantation of a hip prosthesis coated with plasma-sprayed hydroxyapatite]. Frayssinet P; Hardy D; Conte P; Delince P; Guilhem A; Bonel G Rev Chir Orthop Reparatrice Appar Mot; 1993; 79(3):177-84. PubMed ID: 8122005 [TBL] [Abstract][Full Text] [Related]
17. Eight-year results of hydroxyapatite-coated hip arthroplasty. Chang JK; Chen CH; Huang KY; Wang GJ J Arthroplasty; 2006 Jun; 21(4):541-6. PubMed ID: 16781407 [TBL] [Abstract][Full Text] [Related]
18. Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study. Köster G; Rading S Arch Orthop Trauma Surg; 2009 May; 129(5):603-8. PubMed ID: 18379799 [TBL] [Abstract][Full Text] [Related]
19. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up. Zwartelé RE; Olsthoorn PG; Pöll RG; Brand R; Doets HC Arch Orthop Trauma Surg; 2008 Dec; 128(12):1379-86. PubMed ID: 18758793 [TBL] [Abstract][Full Text] [Related]
20. Comparison of the early healing course of porous titanium with hydroxyapatite-coated porous titanium hip implants: clinical considerations for the use of hydroxyapatite coating in total hip replacement. Emerson RH; Head WC; Peters PC Semin Arthroplasty; 1991 Oct; 2(4):295-301. PubMed ID: 10149617 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]