These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

55 related articles for article (PubMed ID: 8116395)

  • 1. [Anatomical and extensometric study concerning the collar support and the prosthetic sleeve. Basis of the conception of an anatomic prosthesis].
    Blaimont P; Delronge G; Smeyers B; Halleux P; Lasudry N; Sintzoff S
    Acta Orthop Belg; 1993; 59 Suppl 1():170-81. PubMed ID: 8116395
    [No Abstract]   [Full Text] [Related]  

  • 2. [Mechanical changes in the femur induced by a joint prosthesis. Comparative extensometric studies].
    Delecrin J; Royer J; Passuty N; Bainvel JV
    Chirurgie; 1991; 117(9):726-31. PubMed ID: 1843673
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An analysis of collar function and the use of titanium in femoral prostheses.
    Crowninshield RD; Brand RA; Johnston RC; Pedersen DR
    Clin Orthop Relat Res; 1981; (158):270-7. PubMed ID: 7273522
    [No Abstract]   [Full Text] [Related]  

  • 4. Optimum pressfit and proximal stress transfer with an improved modular design in total hip arthroplasty.
    Stiehl JB
    Semin Arthroplasty; 1993 Jul; 4(3):167-71. PubMed ID: 10146283
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of newly designed stemless prosthesis and conventional hip prosthesis--an experimental study.
    Tai CL; Lee MS; Chen WP; Hsieh PH; Lee PC; Shih CH
    Biomed Mater Eng; 2005; 15(3):239-49. PubMed ID: 15912004
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The evolution of the Buck-32 total hip prosthesis.
    Mallory TH
    Clin Orthop Relat Res; 1980; (147):148-53. PubMed ID: 7371282
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The development of a physiological hip prosthesis: evaluation of the strains after implantation of a prototype of hip implant: experiment in a dry femur.
    Vander Sloten J; Labey L; Van Audekercke R; Van der Perre G
    Biomed Mater Eng; 1993; 3(1):1-13. PubMed ID: 8490530
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Finite element analysis of changes in femoral stresses after elite total hip arthroplasty].
    He RX; Luo YM; Yan SG; Wu HB
    Zhonghua Yi Xue Za Zhi; 2004 Sep; 84(18):1549-53. PubMed ID: 15500718
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bone mineral density and singh index predict bone mechanical properties of human femur.
    D'Amelio P; Rossi P; Isaia G; Lollino N; Castoldi F; Girardo M; Dettoni F; Sattin F; Delise M; Bignardi C
    Connect Tissue Res; 2008; 49(2):99-104. PubMed ID: 18382896
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of modular tapered fluted stems on proximal stress shielding in the human femur.
    Hnat WP; Conway JS; Malkani AL; Yakkanti MR; Voor MJ
    J Arthroplasty; 2009 Sep; 24(6):957-62. PubMed ID: 18848422
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Mechanical behavior of the upper epiphysis of the resurfaced femur and incidence of anatomical variations and various cup types].
    Crick D; Wagner J; Bourgois R; Dehu P
    Acta Orthop Belg; 1985; 51(2-3):168-80. PubMed ID: 4050374
    [No Abstract]   [Full Text] [Related]  

  • 13. Influence of total hip design on dislocation: a computer model and clinical analysis.
    Padgett DE; Lipman J; Robie B; Nestor BJ
    Clin Orthop Relat Res; 2006 Jun; 447():48-52. PubMed ID: 16741474
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of hip protectors and corresponding hip fracture risk using stress calculation in the femoral neck.
    Spierings AB; Derler S
    Med Eng Phys; 2006 Jul; 28(6):550-9. PubMed ID: 16275044
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Biomechanical experiment of non-stemmed anatomical total hip prosthesis arthroplasty in vitro].
    Fei Q; Hong S; Chen T; Chen Z; Qian B
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Feb; 22(1):104-7. PubMed ID: 15762127
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanics of large femoral heads: what they do and don't do.
    Crowninshield RD; Maloney WJ; Wentz DH; Humphrey SM; Blanchard CR
    Clin Orthop Relat Res; 2004 Dec; (429):102-7. PubMed ID: 15577473
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The Egoform prosthesis--November 1984 - May 1992].
    Moretton JC; Cravoisy JC
    Acta Orthop Belg; 1993; 59 Suppl 1():196-9. PubMed ID: 8116398
    [No Abstract]   [Full Text] [Related]  

  • 18. [Study on design method for the individual anatomical hip joint endoprosthesis].
    Gong X; Kang L; Wang J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):92-6. PubMed ID: 18435265
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A conical-collared intramedullary stem can improve stress transfer and limit micromotion.
    Mandell JA; Carter DR; Goodman SB; Schurman DJ; Beaupré GS
    Clin Biomech (Bristol, Avon); 2004 Aug; 19(7):695-703. PubMed ID: 15288455
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Anatomic Porous Replacement hip arthroplasty: first 100 consecutive cases.
    Dorr LD; Absatz M; Gruen TA; Saberi MT; Doerzbacher JF
    Semin Arthroplasty; 1990 Jul; 1(1):77-86. PubMed ID: 10149561
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.