These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 8118860)

  • 1. Mechanical left ventricular unloading during high risk coronary angioplasty: first use of a new percutaneous transvalvular left ventricular assist device.
    Scholz KH; Figulla HR; Schweda F; Smalling RW; Hellige G; Kreuzer H; Aboul-Hosn W; Wampler RK
    Cathet Cardiovasc Diagn; 1994 Jan; 31(1):61-9. PubMed ID: 8118860
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of a percutaneous Hemopump in high risk coronary angioplasty patients.
    Dubois-Randé JL; Deleuze P; Dupouy P; Geschwind H; Loisance D
    ASAIO J; 1994; 40(3):M486-8. PubMed ID: 8555563
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [High-risk PTCA assisted by the Hemopump 14F: the Geneva experience].
    Panos A; Kalangos A; Urban P
    Schweiz Med Wochenschr; 1999 Oct; 129(42):1529-34. PubMed ID: 10568235
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model.
    Smalling RW; Cassidy DB; Barrett R; Lachterman B; Felli P; Amirian J
    Circulation; 1992 Mar; 85(3):1152-9. PubMed ID: 1537113
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A first-in-man study of the Reitan catheter pump for circulatory support in patients undergoing high-risk percutaneous coronary intervention.
    Smith EJ; Reitan O; Keeble T; Dixon K; Rothman MT
    Catheter Cardiovasc Interv; 2009 Jun; 73(7):859-65. PubMed ID: 19455649
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Supported percutaneous coronary intervention using a novel 6-Fr intra-aortic balloon pump catheter via the brachial artery in a nonagenarian patient with an abdominal aortic aneurysm.
    Takahashi A; Taniguchi N
    Catheter Cardiovasc Interv; 2011 Jun; 77(7):1045-8. PubMed ID: 21413123
    [TBL] [Abstract][Full Text] [Related]  

  • 7. First-in-human experience with Aortix intraaortic pump.
    Vora AN; Schuyler Jones W; DeVore AD; Ebner A; Clifton W; Patel MR
    Catheter Cardiovasc Interv; 2019 Feb; 93(3):428-433. PubMed ID: 30311400
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of mechanical left ventricular unloading by Impella on left ventricular dynamics in high-risk and primary percutaneous coronary intervention patients.
    Remmelink M; Sjauw KD; Henriques JP; de Winter RJ; Vis MM; Koch KT; Paulus WJ; de Mol BA; Tijssen JG; Piek JJ; Baan J
    Catheter Cardiovasc Interv; 2010 Feb; 75(2):187-94. PubMed ID: 19941329
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of the 14F hemopump on coronary hemodynamics in patients undergoing high-risk coronary angioplasty.
    Dubois-Randé JL; Teiger E; Garot J; Aptecar E; Pernès JM; Tixier D; Gueret P; Loisance D; Dupouy P
    Am Heart J; 1998 May; 135(5 Pt 1):844-9. PubMed ID: 9588415
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PTCA with the use of cardiac assist devices: risk stratification, short- and long-term results.
    Ferrari M; Scholz KH; Figulla HR
    Cathet Cardiovasc Diagn; 1996 Jul; 38(3):242-8. PubMed ID: 8804779
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coronary hemodynamics during hemopump left-intraventricular assistance.
    Dubois-Randé JL; Deleuze P; Zelinsky R; Shiiya N; Saal JP; Geschwind H; Loisance D
    Int J Artif Organs; 1992 Apr; 15(4):234-8. PubMed ID: 1587646
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous support devices for high risk or complicated coronary angioplasty.
    Lincoff AM; Popma JJ; Ellis SG; Vogel RA; Topol EJ
    J Am Coll Cardiol; 1991 Mar; 17(3):770-80. PubMed ID: 1993799
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Left-ventricular unloading by transvalvular axial flow pumping in experimental cardiogenic shock and during regional myocardial ischemia.
    Scholz KH; Hering JP; Schröder T; Uhlig P; Kreuzer H; Hellige G
    Cardiology; 1994; 84(3):202-10. PubMed ID: 8205570
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility and long-term safety of elective Impella-assisted high-risk percutaneous coronary intervention: a pilot two-centre study.
    Burzotta F; Paloscia L; Trani C; Mascellanti M; Mongiardo R; Materazzo G; Niccoli G; Di Marco M; Leone AM; Porto I; Mazzari MA; Rebuzzi AG; Schiavoni G; Crea F
    J Cardiovasc Med (Hagerstown); 2008 Oct; 9(10):1004-10. PubMed ID: 18799962
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemopump ventricular support for patients undergoing high risk coronary angioplasty.
    Loisance D; Deleuze P; Dubois-Rande JL; Okude J; Shiiya N; Wan F; Geschwind H
    ASAIO Trans; 1990; 36(3):M623-6. PubMed ID: 2252767
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-risk percutaneous coronary intervention with the TandemHeart and Impella devices: a single-center experience.
    Schwartz BG; Ludeman DJ; Mayeda GS; Kloner RA; Economides C; Burstein S
    J Invasive Cardiol; 2011 Oct; 23(10):417-24. PubMed ID: 21972160
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical experience with the percutaneous hemopump during high-risk coronary angioplasty.
    Scholz KH; Dubois-Rande JL; Urban P; Morice MC; Loisance D; Smalling RW; Figulla HR
    Am J Cardiol; 1998 Nov; 82(9):1107-10, A6. PubMed ID: 9817489
    [TBL] [Abstract][Full Text] [Related]  

  • 18. First Canadian experience with high-risk percutaneous coronary intervention with assistance of a percutaneously deployed left ventricular assist device.
    Eichhöfer J; Osten M; Horlick E; Dzavík V
    Can J Cardiol; 2008 Nov; 24(11):e82-5. PubMed ID: 18987766
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transfemoral placement of the left ventricular assist device "Hemopump" during mechanical resuscitation.
    Scholz KH; Tebbe U; Chemnitius M; Kreuzer H; Schröder T; Hering JP; Uhlig P; Hellige G; Gröne HJ; Autschbach R
    Thorac Cardiovasc Surg; 1990 Apr; 38(2):69-72. PubMed ID: 2349554
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of left ventricular unloading by Impella recover LP2.5 on coronary hemodynamics.
    Remmelink M; Sjauw KD; Henriques JP; de Winter RJ; Koch KT; van der Schaaf RJ; Vis MM; Tijssen JG; Piek JJ; Baan J
    Catheter Cardiovasc Interv; 2007 Oct; 70(4):532-7. PubMed ID: 17896398
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.