These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Osseointegration of titanium implants in total hip arthroplasty. McCutchen JW; Collier JP; Mayor MB Clin Orthop Relat Res; 1990 Dec; (261):114-25. PubMed ID: 2245538 [TBL] [Abstract][Full Text] [Related]
3. Implant design affects markers of bone resorption and formation in total hip replacement. Qureshi AA; Virdi AS; Didonna ML; Jacobs JJ; Masuda K; Paprosky WP; Thonar EJ; Sumner DR J Bone Miner Res; 2002 May; 17(5):800-7. PubMed ID: 12009010 [TBL] [Abstract][Full Text] [Related]
4. Early clinical results of hydroxyapatite-coated total hip arthroplasty. Cates HE; Keating EM; Gittins M; Faris PM; Bissacotti JF; Ritter MA Semin Arthroplasty; 1991 Oct; 2(4):317-22. PubMed ID: 10149620 [TBL] [Abstract][Full Text] [Related]
5. A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model. Turner TM; Sumner DR; Urban RM; Rivero DP; Galante JO J Bone Joint Surg Am; 1986 Dec; 68(9):1396-409. PubMed ID: 3782212 [TBL] [Abstract][Full Text] [Related]
6. Hydroxyapatite porous coating and the osteointegration of the total hip replacement. Landor I; Vavrik P; Sosna A; Jahoda D; Hahn H; Daniel M Arch Orthop Trauma Surg; 2007 Feb; 127(2):81-9. PubMed ID: 17013602 [TBL] [Abstract][Full Text] [Related]
7. The anthropometric total hip femoral prosthesis. Preliminary clinical and roentgenographic findings of exact-fit cementless application. Amstutz HC; Nasser S; More RC; Kabo JM Clin Orthop Relat Res; 1989 May; (242):104-19. PubMed ID: 2706844 [TBL] [Abstract][Full Text] [Related]
8. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis. Nasser S; Campbell PA; Kilgus D; Kossovsky N; Amstutz HC Clin Orthop Relat Res; 1990 Dec; (261):171-85. PubMed ID: 2245543 [TBL] [Abstract][Full Text] [Related]
9. Tapered titanium cementless total hip replacements: a 10- to 13-year followup study. Bourne RB; Rorabeck CH; Patterson JJ; Guerin J Clin Orthop Relat Res; 2001 Dec; (393):112-20. PubMed ID: 11764339 [TBL] [Abstract][Full Text] [Related]
10. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty]. Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572 [TBL] [Abstract][Full Text] [Related]
11. Total hip arthroplasty for acute femoral neck fractures using a cementless tapered femoral stem. Klein GR; Parvizi J; Vegari DN; Rothman RH; Purtill JJ J Arthroplasty; 2006 Dec; 21(8):1134-40. PubMed ID: 17162172 [TBL] [Abstract][Full Text] [Related]
12. Chemical implant fixation using hydroxyl-apatite coatings. The development of a human total hip prosthesis for chemical fixation to bone using hydroxyl-apatite coatings on titanium substrates. Geesink RG; de Groot K; Klein CP Clin Orthop Relat Res; 1987 Dec; (225):147-70. PubMed ID: 2824115 [TBL] [Abstract][Full Text] [Related]
13. Effects of some technological aspects on the fatigue strength of a cementless hip stem. Viceconti M; Toni A; Giunti A J Biomed Mater Res; 1995 Jul; 29(7):875-81. PubMed ID: 7593027 [TBL] [Abstract][Full Text] [Related]
14. A plasma-sprayed titanium proximal coating reduces the risk of periprosthetic femoral fracture in cementless hip arthroplasty. Miles B; Walter WL; Kolos E; Waters T; Appleyard R; Gillies RM; Donohoo S; Ruys AJ Biomed Mater Eng; 2015; 25(3):267-78. PubMed ID: 26407113 [TBL] [Abstract][Full Text] [Related]
15. Mechanical properties of porous metal total hip prostheses. Crowninshield RD Instr Course Lect; 1986; 35():144-8. PubMed ID: 3819401 [TBL] [Abstract][Full Text] [Related]
16. Principles of acetabular fixation in THR with special reference to the "press-fit cup". Morscher E Acta Orthop Belg; 1993; 59 Suppl 1():260-6. PubMed ID: 8116408 [TBL] [Abstract][Full Text] [Related]
17. The effect of polyelectrolyte multilayer coated titanium alloy surfaces on implant anchorage in rats. Zankovych S; Diefenbeck M; Bossert J; Mückley T; Schrader C; Schmidt J; Schubert H; Bischoff S; Faucon M; Finger U; Jandt KD Acta Biomater; 2013 Jan; 9(1):4926-34. PubMed ID: 22902814 [TBL] [Abstract][Full Text] [Related]
19. [On the history of cementless implants in extremity surgery]. Dufek P Unfallchirurg; 2017 May; 120(5):367-370. PubMed ID: 28144690 [TBL] [Abstract][Full Text] [Related]
20. [Acetabular screw rings and surface effects: apropos of a continuous series of 115 primary implantations of Karl Zweymüller's acetabular screw rings after a follow-up of an average of 5.8 years]]. Delaunay C; Kapandji AI Rev Chir Orthop Reparatrice Appar Mot; 1994; 80(5):388-402. PubMed ID: 7746924 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]