These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Thigh pain, subsidence and survival using a short cementless femoral stem with pure metaphyseal fixation at minimum 9-year follow-up. Cinotti G; Della Rocca A; Sessa P; Ripani FR; Giannicola G Orthop Traumatol Surg Res; 2013 Feb; 99(1):30-6. PubMed ID: 23260613 [TBL] [Abstract][Full Text] [Related]
24. Modular calcar replacement prosthesis with strengthened taper junction in total hip arthroplasty. Lombardi AV; Berend KR; Mallory TH; Adams JB Surg Technol Int; 2007; 16():206-9. PubMed ID: 17429790 [TBL] [Abstract][Full Text] [Related]
25. [Mid-term effectiveness of total hip arthroplasty with collum femoris preserving prosthesis]. Li M; Hu Y; Li K; Liao Q; Wen T; Zhong D Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2012 Aug; 26(8):897-901. PubMed ID: 23012917 [TBL] [Abstract][Full Text] [Related]
26. Revision total hip arthroplasty with titanium ingrowth prosthesis and bone grafting for failed cemented femoral component loosening. Gustilo RB; Pasternak HS Clin Orthop Relat Res; 1988 Oct; (235):111-9. PubMed ID: 3416518 [TBL] [Abstract][Full Text] [Related]
27. Cementless total hip arthroplasty in patients fifty years of age or younger: a minimum ten-year follow-up. Takenaga RK; Callaghan JJ; Bedard NA; Liu SS; Klaassen AL; Pedersen DR J Bone Joint Surg Am; 2012 Dec; 94(23):2153-9. PubMed ID: 23224386 [TBL] [Abstract][Full Text] [Related]
28. Total hip arthroplasty with an uncemented tapered femoral component. McLaughlin JR; Lee KR J Bone Joint Surg Am; 2008 Jun; 90(6):1290-6. PubMed ID: 18519323 [TBL] [Abstract][Full Text] [Related]
29. Long-term results of femoral revision with the Wagner Self-Locking stem. Regis D; Sandri A; Bonetti I Surg Technol Int; 2013 Sep; 23():243-50. PubMed ID: 24081844 [TBL] [Abstract][Full Text] [Related]
30. Evaluation of uncemented total hip arthroplasty in patients with avascular necrosis of the femoral head. Lins RE; Barnes BC; Callaghan JJ; Mair SD; McCollum DE Clin Orthop Relat Res; 1993 Dec; (297):168-73. PubMed ID: 8242926 [TBL] [Abstract][Full Text] [Related]
31. The CAD hip arthroplasty. Five to ten-year follow-up. Thomas BJ; Salvati EA; Small RD J Bone Joint Surg Am; 1986 Jun; 68(5):640-6. PubMed ID: 3722220 [TBL] [Abstract][Full Text] [Related]
32. Prediction of outcome of total hip arthroplasty based on initial postoperative radiographic analysis. Matched, paired comparisons of failed versus successful femoral components. Tapadiya D; Walker RH; Schurman DJ Clin Orthop Relat Res; 1984 Jun; (186):5-15. PubMed ID: 6723160 [TBL] [Abstract][Full Text] [Related]
33. Incidence of intraoperative femoral fracture. Straight-stemmed versus anatomic cementless total hip arthroplasty. Toni A; Ciaroni D; Sudanese A; Femino F; Marraro MD; Bueno Lozano AL; Giunti A Acta Orthop Belg; 1994; 60(1):43-54. PubMed ID: 8171987 [TBL] [Abstract][Full Text] [Related]
35. 10 years results of an uncemented metaphyseal fit modular stem in elderly patients. De la Torre BJ; Chaparro M; Romanillos JO; Zarzoso S; Mosquera M; Rodriguez G Indian J Orthop; 2011 Jul; 45(4):351-8. PubMed ID: 21772630 [TBL] [Abstract][Full Text] [Related]
36. Promising mid-term results of total hip arthroplasties using an uncemented lateral-flare hip prosthesis: a clinical and radiographic study. Leali A; Fetto J Int Orthop; 2007 Dec; 31(6):845-9. PubMed ID: 18008097 [TBL] [Abstract][Full Text] [Related]
37. Peroperative fractures in uncemented total hip arthroplasty: results with a single design of stem implant. Fernandez-Fernandez R; García-Elias E; Gil-Garay E Int Orthop; 2008 Jun; 32(3):307-13. PubMed ID: 17237945 [TBL] [Abstract][Full Text] [Related]
38. The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty. Wu LD; Hahne HJ; Hassenpflug J J Zhejiang Univ Sci; 2004 Oct; 5(10):1270-8. PubMed ID: 15362200 [TBL] [Abstract][Full Text] [Related]