These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 8125510)

  • 1. An acoustical guidance and position monitoring system for endotracheal tubes.
    Mansfield JP; Lyle RP; Voorhees WD; Wodicka GR
    IEEE Trans Biomed Eng; 1993 Dec; 40(12):1330-5. PubMed ID: 8125510
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Miniature acoustic guidance system for endotracheal tubes.
    Juan EJ; Mansfield JP; Wodicka GR
    IEEE Trans Biomed Eng; 2002 Jun; 49(6):584-96. PubMed ID: 12046704
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative study of endotracheal tube positioning methods in children: safety from neck movement.
    Yoo SY; Kim JH; Han SH; Oh AY
    Anesth Analg; 2007 Sep; 105(3):620-5. PubMed ID: 17717214
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Down syndrome: analysis of airway size and a guide for appropriate intubation.
    Shott SR
    Laryngoscope; 2000 Apr; 110(4):585-92. PubMed ID: 10764002
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acoustic method to quantitatively assess the position and patency of infant endotracheal tubes: preliminary results in rabbits.
    Mansfield JP; Shannon DC; Wodicka GR
    Pediatr Pulmonol; 1998 Nov; 26(5):354-61. PubMed ID: 9859906
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tracheal palpation to assess endotracheal tube depth: an exploratory study.
    McKay WP; Klonarakis J; Pelivanov V; O'Brien JM; Plewes C
    Can J Anaesth; 2014 Mar; 61(3):229-34. PubMed ID: 24259250
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel method to position an endotracheal tube at the correct depth using an infrared sensor stylet.
    Song Y; Oh J; Chee Y; Lim T; Kang H; Cho Y
    Can J Anaesth; 2013 May; 60(5):444-9. PubMed ID: 23370979
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a portable infrared end-tidal carbon dioxide monitor during pediatric interhospital transport.
    Bhende MS; Karr VA; Wiltsie DC; Orr RA
    Pediatrics; 1995 Jun; 95(6):875-8. PubMed ID: 7761213
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Can novice sonographers accurately locate an endotracheal tube with a saline-filled cuff in a cadaver model? A pilot study.
    Uya A; Spear D; Patel K; Okada P; Sheeran P; McCreight A
    Acad Emerg Med; 2012 Mar; 19(3):361-4. PubMed ID: 22435870
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improving styletted oral tracheal intubation: rational use of the OTSU.
    Stasiuk RB
    Can J Anaesth; 2001 Oct; 48(9):911-8. PubMed ID: 11606350
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tracheal-innominate artery fistula caused by the endotracheal tube tip: case report and investigation of a fatal complication of prolonged intubation.
    Siobal M; Kallet RH; Kraemer R; Jonson E; Lemons D; Young D; Campbell AR; Schecter W; Tang J
    Respir Care; 2001 Oct; 46(10):1012-8. PubMed ID: 11572753
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A visual stethoscope to detect the position of the tracheal tube.
    Kato H; Suzuki A; Nakajima Y; Makino H; Sanjo Y; Nakai T; Shiraishi Y; Katoh T; Sato S
    Anesth Analg; 2009 Dec; 109(6):1836-42. PubMed ID: 19923511
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pediatric airway and esophageal profiles with acoustic reflectometry.
    Gucev G; Raphael DT; Elspas S; Glass G
    Anesth Analg; 2006 Nov; 103(5):1126-30. PubMed ID: 17056944
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparison of a new, ultrathin-walled two-stage twin endotracheal tube and a conventional endotracheal tube in very premature infants with respiratory distress syndrome: a pilot study.
    Parravicini E; Baccarelli A; Wung JT; Kolobow T; Lorenz JM
    Am J Perinatol; 2007 Feb; 24(2):117-22. PubMed ID: 17304419
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Negative intratracheal pressure produced by esophageal detector devices causes tracheal wall collapse in a porcine cardiac arrest model.
    Schuh JR; Bettendorf R; Shapiro D; Trowbridge DL; Lujan E; Boyle P; Birmingham S; Dacanay R; Green R
    Anesth Analg; 2010 Aug; 111(2):468-72. PubMed ID: 20584869
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tracheal shortening during laparoscopic gynecologic surgery.
    Kim JH; Hong DM; Oh AY; Han SH
    Acta Anaesthesiol Scand; 2007 Feb; 51(2):235-8. PubMed ID: 17181537
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of a novel anatomically shaped endotracheal tube on intubation-related injury.
    Gordin A; Chadha NK; Campisi P; Luginbuehl I; Taylor G; Forte V
    Arch Otolaryngol Head Neck Surg; 2010 Jan; 136(1):54-9. PubMed ID: 20083779
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection and correction of endotracheal-tube position in premature neonates.
    Lange M; Jonat S; Nikischin W
    Pediatr Pulmonol; 2002 Dec; 34(6):455-61. PubMed ID: 12422343
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of diameter, length, and circuit pressure on sound conductance through endotracheal tubes.
    Räsänen JO; Rosenhouse G; Gavriely N
    IEEE Trans Biomed Eng; 2006 Jul; 53(7):1255-64. PubMed ID: 16830930
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Endotracheal intubation attempts during neonatal resuscitation: success rates, duration, and adverse effects.
    O'Donnell CP; Kamlin CO; Davis PG; Morley CJ
    Pediatrics; 2006 Jan; 117(1):e16-21. PubMed ID: 16396845
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.