These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. A comparison of the Vasotrac with invasive arterial blood pressure monitoring in children after pediatric cardiac surgery. Cua CL; Thomas K; Zurakowski D; Laussen PC Anesth Analg; 2005 May; 100(5):1289-1294. PubMed ID: 15845671 [TBL] [Abstract][Full Text] [Related]
3. Continuous noninvasive finger blood pressure during controlled hypotension. A comparison with intraarterial pressure. Epstein RH; Bartkowski RR; Huffnagle S Anesthesiology; 1991 Nov; 75(5):796-803. PubMed ID: 1952205 [TBL] [Abstract][Full Text] [Related]
4. The reliability of continuous noninvasive finger blood pressure measurement in critically ill children. Lemson J; Hofhuizen CM; Schraa O; Settels JJ; Scheffer GJ; van der Hoeven JG Anesth Analg; 2009 Mar; 108(3):814-21. PubMed ID: 19224788 [TBL] [Abstract][Full Text] [Related]
5. The CNAP™ Finger Cuff for Noninvasive Beat-To-Beat Monitoring of Arterial Blood Pressure: An Evaluation in Intensive Care Unit Patients and a Comparison with 2 Intermittent Devices. Lakhal K; Martin M; Faiz S; Ehrmann S; Blanloeil Y; Asehnoune K; Rozec B; Boulain T Anesth Analg; 2016 Nov; 123(5):1126-1135. PubMed ID: 27159068 [TBL] [Abstract][Full Text] [Related]
6. Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure. Constant I; Laude D; Elghozi JL; Murat I J Clin Monit Comput; 1999 May; 15(3-4):205-14. PubMed ID: 12568172 [TBL] [Abstract][Full Text] [Related]
7. Accuracy of beat-to-beat noninvasive measurement of finger arterial pressure using the Finapres: a spectral analysis approach. Novak V; Novak P; Schondorf R J Clin Monit; 1994 Mar; 10(2):118-26. PubMed ID: 8207452 [TBL] [Abstract][Full Text] [Related]
8. Comparison of arterial tonometry with radial artery catheter measurements of blood pressure in anesthetized patients. Siegel LC; Brock-Utne JG; Brodsky JB Anesthesiology; 1994 Sep; 81(3):578-84. PubMed ID: 8092502 [TBL] [Abstract][Full Text] [Related]
10. Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device. Saugel B; Meidert AS; Hapfelmeier A; Eyer F; Schmid RM; Huber W Br J Anaesth; 2013 Aug; 111(2):185-90. PubMed ID: 23491946 [TBL] [Abstract][Full Text] [Related]
11. Comparison of intrabrachial and finger blood pressure in healthy elderly volunteers. Rongen GA; Bos WJ; Lenders JW; van Montfrans GA; van Lier HJ; van Goudoever J; Wesseling KH; Thien T Am J Hypertens; 1995 Mar; 8(3):237-48. PubMed ID: 7794572 [TBL] [Abstract][Full Text] [Related]
12. Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing. Parati G; Casadei R; Groppelli A; Di Rienzo M; Mancia G Hypertension; 1989 Jun; 13(6 Pt 1):647-55. PubMed ID: 2500393 [TBL] [Abstract][Full Text] [Related]
13. Accuracy of the CNAP™ monitor, a noninvasive continuous blood pressure device, in providing beat-to-beat blood pressure readings in pediatric patients weighing 20-40 kilograms. Kako H; Corridore M; Rice J; Tobias JD Paediatr Anaesth; 2013 Nov; 23(11):989-93. PubMed ID: 23565770 [TBL] [Abstract][Full Text] [Related]
14. Oscillometric and intra-arterial blood pressure in children post-kidney transplantation: Is invasive blood pressure measurement always needed? Marouane A; Cornelissen EAM; Nusmeier A; Bootsma-Robroeks CMHHT Pediatr Transplant; 2019 Feb; 23(1):e13309. PubMed ID: 30362265 [TBL] [Abstract][Full Text] [Related]
15. Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients. Wagner JY; Negulescu I; Schöfthaler M; Hapfelmeier A; Meidert AS; Huber W; Schmid RM; Saugel B J Clin Monit Comput; 2015 Dec; 29(6):807-13. PubMed ID: 25726179 [TBL] [Abstract][Full Text] [Related]
16. The reliability of noninvasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease. Bos WJ; Imholz BP; van Goudoever J; Wesseling KH; van Montfrans GA Am J Hypertens; 1992 Aug; 5(8):529-35. PubMed ID: 1388963 [TBL] [Abstract][Full Text] [Related]
17. Accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients. Hirschl MM; Binder M; Herkner H; Bur A; Brunner M; Seidler D; Stühlinger HG; Laggner AN Crit Care Med; 1996 Oct; 24(10):1684-9. PubMed ID: 8874306 [TBL] [Abstract][Full Text] [Related]
18. The relative accuracies of two automated noninvasive arterial pressure measurement devices. Gorback MS; Quill TJ; Lavine ML J Clin Monit; 1991 Jan; 7(1):13-22. PubMed ID: 1999694 [TBL] [Abstract][Full Text] [Related]
19. Noninvasive, continuous blood pressure measurement by arterial tonometry during anesthesia in children. Kemmotsu O; Ohno M; Takita K; Sugimoto H; Otsuka H; Morimoto Y; Mayumi T Anesthesiology; 1994 Nov; 81(5):1162-8. PubMed ID: 7978474 [TBL] [Abstract][Full Text] [Related]
20. Noninvasive assessment of arterial pressure. Chemla D; Teboul JL; Richard C Curr Opin Crit Care; 2008 Jun; 14(3):317-21. PubMed ID: 18467893 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]