These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 8127984)

  • 1. Exit dose measurements by portal film dosimetry.
    Fiorino C; del Vecchio A; Cattaneo GM; Fusca M; Longobardi B; Signorotto P; Calandrino R
    Radiother Oncol; 1993 Dec; 29(3):336-40. PubMed ID: 8127984
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurements of exit dose profiles in 60Co beams with a conventional portal film system.
    Stasi M; Casanova Borca V; Fiorino C
    Br J Radiol; 1997 Dec; 70(840):1283-7. PubMed ID: 9505849
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo verification of electron beam energy by patient exit dose and optical density of portal films.
    Geyer P; Baus WW; Baumann M
    Strahlenther Onkol; 2004 Jan; 180(1):62-5. PubMed ID: 14704847
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Normalized sensitometric curves for the verification of hybrid IMRT treatment plans with multiple energies.
    Georg D; Kroupa B; Winkler P; Pötter R
    Med Phys; 2003 Jun; 30(6):1142-50. PubMed ID: 12852539
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.
    McCaw TJ; Micka JA; DeWerd LA
    Med Phys; 2014 May; 41(5):052104. PubMed ID: 24784393
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Kilovoltage transit and exit dosimetry for a small animal image-guided radiotherapy system using built-in EPID.
    Anvari A; Poirier Y; Sawant A
    Med Phys; 2018 Oct; 45(10):4642-4651. PubMed ID: 30118144
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.
    Chetty IJ; Charland PM
    Phys Med Biol; 2002 Oct; 47(20):3629-41. PubMed ID: 12433124
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Midplane dose determination using in vivo dose measurements in combination with portal imaging.
    Huyskens D; Van Dam J; Dutreix A
    Phys Med Biol; 1994 Jul; 39(7):1089-101. PubMed ID: 15552099
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A reusable OSL-film for 2D radiotherapy dosimetry.
    Wouter C; Dirk V; Paul L; Tom D
    Phys Med Biol; 2017 Oct; 62(21):8441-8454. PubMed ID: 29047456
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of dose inhomogeneities in clinical practice by film dosimetry.
    Weltens C; Huyskens D; Dutreix A; van der Schueren E
    Radiother Oncol; 1998 Dec; 49(3):287-94. PubMed ID: 10075262
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Variation of relative transit dose profiles with patient-detector distance.
    Bogaerts R; Huyskens D; Weltens C; Dutreix A
    Radiother Oncol; 2000 Jan; 54(1):29-37. PubMed ID: 10719697
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dose calculation and dosimetry tests for clinical implementation of 1D tissue-deficit compensation by a single dynamic absorber.
    Corletto D; Fiorino C; Cattaneo GM; Mangili P; Calandrino R
    Radiother Oncol; 1998 Apr; 47(1):53-62. PubMed ID: 9632293
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Are port films reliable for in vivo exit dose measurements?
    Van Dam J; Vaerman C; Blanckaert N; Leunens G; Dutreix A; van der Schueren E
    Radiother Oncol; 1992 Sep; 25(1):67-72. PubMed ID: 1410593
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design and implementation of a water phantom for IMRT, arc therapy, and tomotherapy dose distribution measurements.
    Pallotta S; Marrazzo L; Bucciolini M
    Med Phys; 2007 Oct; 34(10):3724-31. PubMed ID: 17985617
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A simple and robust method for in vivo midline dose map estimations using diodes and portal detectors.
    Broggi S; Fiorino C; Calandrino R
    Radiother Oncol; 2001 Feb; 58(2):169-78. PubMed ID: 11166868
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reference radiochromic film dosimetry in kilovoltage photon beams during CBCT image acquisition.
    Tomic N; Devic S; DeBlois F; Seuntjens J
    Med Phys; 2010 Mar; 37(3):1083-92. PubMed ID: 20384244
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Matchline dosimetry in step and shoot IMRT fields: a film study.
    Tangboonduangjit P; Metcalfe P; Butson M; Quach KY; Rosenfeld A
    Phys Med Biol; 2004 Sep; 49(17):N287-92. PubMed ID: 15470934
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The use of new GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water phantom.
    Chiu-Tsao ST; Medich D; Munro J
    Med Phys; 2008 Aug; 35(8):3787-99. PubMed ID: 18777938
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors.
    Somigliana A; Cattaneo GM; Fiorino C; Borelli S; del Vecchio A; Zonca G; Pignoli E; Loi G; Calandrino R; Marchesini R
    Phys Med Biol; 1999 Apr; 44(4):887-97. PubMed ID: 10232803
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.