These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

63 related articles for article (PubMed ID: 8134601)

  • 1. Stair-step artifacts in three-dimensional helical CT: an experimental study.
    Wang G; Vannier MW
    Radiology; 1994 Apr; 191(1):79-83. PubMed ID: 8134601
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technical aspects of helical (spiral) CT.
    Brink JA
    Radiol Clin North Am; 1995 Sep; 33(5):825-41. PubMed ID: 7676010
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stair-step artifacts with single versus multiple detector-row helical CT.
    Fleischmann D; Rubin GD; Paik DS; Yen SY; Hilfiker PR; Beaulieu CF; Napel S
    Radiology; 2000 Jul; 216(1):185-96. PubMed ID: 10887247
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Helical CT: principles and technical considerations.
    Brink JA; Heiken JP; Wang G; McEnery KW; Schlueter FJ; Vannier MW
    Radiographics; 1994 Jul; 14(4):887-93. PubMed ID: 7938775
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-dimensional craniocervical helical CT: is isotropic imaging possible?
    Levy RA
    Radiology; 1995 Dec; 197(3):645-8. PubMed ID: 7480732
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Simulation and experimental study of cone artifact in spiral CT].
    Lin YQ; Yang KC; Yu XE
    Nan Fang Yi Ke Da Xue Xue Bao; 2006 Nov; 26(11):1616-8. PubMed ID: 17121714
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Novel Reconstruction Technique to Reduce Stair-Step Artifacts in Sequential Mode Coronary CT Angiography.
    Moser LJ; Mergen V; Allmendinger T; Manka R; Eberhard M; Alkadhi H
    Invest Radiol; 2024 Jan; ():. PubMed ID: 38284879
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A trial to reduce cardiac motion artifact on HR-CT images of the lung with the use of subsecond scan and special cine reconstruction algorithm].
    Sakai F; Shen Y; Horiuchi T; Tsuuchi Y; Suzuki K; Ueno E; Yamada T; Kimura F; Okawa T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1998 May; 58(6):296-8. PubMed ID: 9656701
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of image acquisition parameters on CT artifacts and polyp depiction in spiral CT colonography: in vitro evaluation.
    Whiting BR; McFarland EG; Brink JA
    Radiology; 2000 Oct; 217(1):165-72. PubMed ID: 11012440
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of spiral computed tomography versus conventional computed tomography multiplanar reconstructions of a fracture displacement phantom.
    McEnery KW; Wilson AJ; Murphy WA
    Invest Radiol; 1994 Jul; 29(7):665-70. PubMed ID: 7960611
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Factors of image quality in spiral x-ray computed tomography].
    Ernst O; Gaillandre L; Mizrahi D; Sergent G; Bonvarlet P; L'Herminé C
    J Radiol; 1995 Dec; 76(12):1069-74. PubMed ID: 8676293
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of helical and serial CT with regard to three-dimensional imaging of musculoskeletal anatomy.
    Ney DR; Fishman EK; Kawashima A; Robertson DD; Scott WW
    Radiology; 1992 Dec; 185(3):865-9. PubMed ID: 1438777
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory.
    Tang X; Hsieh J; Hagiwara A; Nilsen RA; Thibault JB; Drapkin E
    Phys Med Biol; 2005 Aug; 50(16):3889-905. PubMed ID: 16077234
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of two iterative techniques for reducing metal artifacts in computed tomography.
    Boas FE; Fleischmann D
    Radiology; 2011 Jun; 259(3):894-902. PubMed ID: 21357521
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters.
    Shin JH; Lee HK; Choi CG; Suh DC; Lim TH; Kang W
    Korean J Radiol; 2002; 3(1):49-56. PubMed ID: 11919479
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.
    Tang X; Hsieh J; Nilsen RA; Dutta S; Samsonov D; Hagiwara A
    Phys Med Biol; 2006 Feb; 51(4):855-74. PubMed ID: 16467583
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multislice CT virtual intravascular endoscopy for abdominal aortic aneurysm stent grafts.
    Sun Z; Gallagher E
    J Vasc Interv Radiol; 2004 Sep; 15(9):961-70. PubMed ID: 15361564
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preliminary study on helical CT algorithms for patient motion estimation and compensation.
    Wang G; Vannier MW
    IEEE Trans Med Imaging; 1995; 14(2):205-11. PubMed ID: 18215824
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Study of helical CT low-contrast resolution and its influencing factors].
    Liu JX; Chen DG
    Zhongguo Yi Liao Qi Xie Za Zhi; 2000 Mar; 24(3):165-7. PubMed ID: 12583125
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spiral CT of the lungs: optimal technique and resolution compared with conventional CT.
    Paranjpe DV; Bergin CJ
    AJR Am J Roentgenol; 1994 Mar; 162(3):561-7. PubMed ID: 8109496
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.