These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 8142581)

  • 1. [Development of a mathematical model for simulation of artificial ventilation].
    Obermayer A; Wittmann J; Lang S
    Biomed Tech (Berl); 1994; 39(1-2):19-26. PubMed ID: 8142581
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Correction of error in respiratory resistance measurements made with the flow-interruption technique during mechanical ventilation: evaluation of the puritan bennett 7200 and 840 ventilators.
    Lit LM; Doelken P; Mayo PH
    Respir Care; 2004 Sep; 49(9):1022-8. PubMed ID: 15329173
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Analysis and realization of new methods of testing the artificial ventilation of lungs (AVL) equipment].
    Gal'perin IuSh; Alkhimova LR; Safronov AIu
    Med Tekh; 2003; (4):3-11. PubMed ID: 14518108
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Theoretical study of inspiratory flow waveforms during mechanical ventilation on pulmonary blood flow and gas exchange.
    Niranjan SC; Bidani A; Ghorbel F; Zwischenberger JB; Clark JW
    Comput Biomed Res; 1999 Aug; 32(4):355-90. PubMed ID: 10469530
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Studies on lung-model ventilation with the Engström respirator. Effect of various airway resistances and respirator settings.
    Elfström J; Hedenstierna G; Oquist L
    Acta Anaesthesiol Scand; 1972; 16(2):85-95. PubMed ID: 4507045
    [No Abstract]   [Full Text] [Related]  

  • 6. Simulating gas flow through the exhalation leg of a respirator's patient circuit.
    Guillaume DW; Borrello MA
    J Biomed Eng; 1991 Jan; 13(1):77-82. PubMed ID: 2002678
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulation of mechanical respiration using a multicompartment model for ventilation mechanics and gas exchange.
    Winkler T; Krause A; Kaiser S
    Int J Clin Monit Comput; 1995; 12(4):231-9. PubMed ID: 8820330
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Noninvasive determination of tracheal pressure in ventilated children--a model study].
    Kessler V; Mols G; Hentschel R; Geiger K; Guttmann J
    Biomed Tech (Berl); 1997; 42 Suppl():289-90. PubMed ID: 9517156
    [No Abstract]   [Full Text] [Related]  

  • 9. Physical aspects of automatic respirators.
    Baum M; Benzer H
    Med Prog Technol; 1975 Dec; 3(3):105-9. PubMed ID: 1061860
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimizing patient-ventilator interaction: how we sync about it?
    Tanios MA; Epstein SK
    Crit Care Med; 2008 Feb; 36(2):631-3. PubMed ID: 18216620
    [No Abstract]   [Full Text] [Related]  

  • 11. A new method for measurement of airway occlusion pressure.
    Brenner M; Mukai DS; Russell JE; Spiritus EM; Wilson AF
    Chest; 1990 Aug; 98(2):421-7. PubMed ID: 2376174
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Therapeutic value of insufflation volume flow function in mechanical ventilation].
    Kliemann JU; Lippmann HG
    Biomed Tech (Berl); 1990; 35 Suppl 3():184-5. PubMed ID: 2078689
    [No Abstract]   [Full Text] [Related]  

  • 13. An ACSL simulation of the respiratory system.
    Vielle B; Chauvet G
    Int J Biomed Comput; 1993 Jul; 33(1):45-54. PubMed ID: 8349358
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical ventilation. Physiology, equipment design, and management.
    Popovich J
    Postgrad Med; 1986 Jan; 79(1):217-20, 223-4, 226-7. PubMed ID: 3510424
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Proportional assist ventilation system based on proportional solenoid valve control.
    Lua AC; Shi KC; Chua LP
    Med Eng Phys; 2001 Jul; 23(6):381-9. PubMed ID: 11551814
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Computer-controlled mechanical simulation of the artificially ventilated human respiratory system.
    Mesić S; Babuska R; Hoogsteden HC; Verbraak AF
    IEEE Trans Biomed Eng; 2003 Jun; 50(6):731-43. PubMed ID: 12814240
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effectiveness of pressure support ventilation for mechanical ventilatory support in patients with status asthmaticus.
    Tokioka H; Saito S; Takahashi T; Kinjo M; Saeki S; Kosaka F; Hirakawa M
    Acta Anaesthesiol Scand; 1992 Jan; 36(1):5-9. PubMed ID: 1539479
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Effect of background flow on the accuracy of respiratory flow and respiratory volume measurement in newborn infants].
    Foitzik B; Schmalisch G; Wauer RR
    Biomed Tech (Berl); 1995 Oct; 40(10):282-8. PubMed ID: 8527640
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Theoretical and experimental pressure behavior and volume distribution in a model of the lung during artificial ventilation].
    Cancelli C; De Renzo A; Giardina B; Vatta F
    Minerva Anestesiol; 1971 Jan; 37(1):2-47. PubMed ID: 5284409
    [No Abstract]   [Full Text] [Related]  

  • 20. Artificial ventilation during transport: A randomized crossover study of manual resuscitators with comparison to mechanical ventilators in a simulation model.
    Lucy MJ; Gamble JJ; Peeling A; Lam JTH; Balbuena L
    Paediatr Anaesth; 2018 Sep; 28(9):788-794. PubMed ID: 30175433
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.