These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 8145994)

  • 1. Measurement of elastic modulus of the central bovine cornea by means of holographic interferometry. Part II. Results.
    Förster W; Kasprzak H; von Bally G
    Optom Vis Sci; 1994 Jan; 71(1):27-32. PubMed ID: 8145994
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of elastic modulus of the bovine cornea by means of holographic interferometry. Part 1. Method and experiment.
    Kasprzak H; Förster W; von Bally G
    Optom Vis Sci; 1993 Jul; 70(7):535-44. PubMed ID: 8355965
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Holographic interferometry of intact and radially incised human eye-bank corneas.
    Smolek MK
    J Cataract Refract Surg; 1994 May; 20(3):277-86. PubMed ID: 8064603
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In Vivo Noninvasive Measurement of Young's Modulus of Elasticity in Human Eyes: A Feasibility Study.
    Sit AJ; Lin SC; Kazemi A; McLaren JW; Pruet CM; Zhang X
    J Glaucoma; 2017 Nov; 26(11):967-973. PubMed ID: 28858155
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correlation of corneal acoustic and elastic properties in a canine eye model.
    He X; Liu J
    Invest Ophthalmol Vis Sci; 2011 Feb; 52(2):731-6. PubMed ID: 20926820
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Young's modulus in normal corneas and the effect on applanation tonometry.
    Hamilton KE; Pye DC
    Optom Vis Sci; 2008 Jun; 85(6):445-50. PubMed ID: 18521022
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Holographic analysis of displacement of the bovine cornea after disruption of intact structures].
    Förster W; Kasprzak H; von Bally G; Busse H
    Ophthalmologe; 1992 Dec; 89(6):531-4. PubMed ID: 1486273
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Depth-Dependent Out-of-Plane Young's Modulus of the Human Cornea.
    Ramirez-Garcia MA; Sloan SR; Nidenberg B; Khalifa YM; Buckley MR
    Curr Eye Res; 2018 May; 43(5):595-604. PubMed ID: 29283675
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Age-related differences in the elasticity of the human cornea.
    Knox Cartwright NE; Tyrer JR; Marshall J
    Invest Ophthalmol Vis Sci; 2011 Jun; 52(7):4324-9. PubMed ID: 20847118
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modelling the elastic properties of the anterior eye and their contribution to maintenance of image quality: the role of the limbus.
    Asejczyk-Widlicka M; Sródka DW; Kasprzak H; Pierscionek BK
    Eye (Lond); 2007 Aug; 21(8):1087-94. PubMed ID: 16823462
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The elastic modulus of central and perilimbal bovine cornea.
    Reichel E; Miller D; Blanco E; Mastanduno R
    Ann Ophthalmol; 1989 Jun; 21(6):205-8. PubMed ID: 2764431
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Qualitative analysis of the elasticity of the bovine cornea by holographic interferometry].
    Förster W; Kasprzak H; von Bally G; Busse H
    Klin Monbl Augenheilkd; 1992 Jan; 200(1):54-9. PubMed ID: 1583845
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of excimer laser keratectomy on the mechanical performance of the human cornea.
    Hjortdal JO; Ehlers N
    Acta Ophthalmol Scand; 1995 Feb; 73(1):18-24. PubMed ID: 7627753
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Elasticity of the bovine sclera measured with real-time holographic interferometry.
    Smolek M
    Am J Optom Physiol Opt; 1988 Aug; 65(8):653-60. PubMed ID: 3177591
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Holographic interferometry of excimer-laser-ablated bovine eyes: first results.
    Förster W; Stupp T; Kasprzak H
    Ophthalmologica; 2003; 217(1):62-7. PubMed ID: 12566876
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extensibility of the normo-hydrated human cornea.
    Hjortdal JO
    Acta Ophthalmol Scand; 1995 Feb; 73(1):12-7. PubMed ID: 7627752
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of corneal tangent modulus using ultrasound indentation.
    Wang LK; Huang YP; Tian L; Kee CS; Zheng YP
    Ultrasonics; 2016 Sep; 71():20-28. PubMed ID: 27262352
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Delineating Corneal Elastic Anisotropy in a Porcine Model Using Noncontact OCT Elastography and Ex Vivo Mechanical Tests.
    Kirby MA; Pitre JJ; Liou HC; Li DS; Wang RK; Pelivanov I; O'Donnell M; Shen TT
    Ophthalmol Sci; 2021 Dec; 1(4):100058. PubMed ID: 36246948
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of changing intraocular pressure on the corneal and scleral curvatures in the fresh porcine eye.
    Pierscionek BK; Asejczyk-Widlicka M; Schachar RA
    Br J Ophthalmol; 2007 Jun; 91(6):801-3. PubMed ID: 17151057
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Regional elastic performance of the human cornea.
    Hjortdal JO
    J Biomech; 1996 Jul; 29(7):931-42. PubMed ID: 8809623
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.