These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 8150838)
21. Decreased wound contraction with fibrin glue--treated skin grafts. Brown DM; Barton BR; Young VL; Pruitt BA Arch Surg; 1992 Apr; 127(4):404-6. PubMed ID: 1558491 [TBL] [Abstract][Full Text] [Related]
22. Fibrin glue: its use for skin grafting of contaminated burn wounds in areas difficult to immobilize. Vedung S; Hedlung A J Burn Care Rehabil; 1993; 14(3):356-8. PubMed ID: 8360243 [TBL] [Abstract][Full Text] [Related]
23. Effect of modern fibrin glue on bleeding after tonsillectomy and adenoidectomy. Vaiman M; Eviatar E; Shlamkovich N; Segal S Ann Otol Rhinol Laryngol; 2003 May; 112(5):410-4. PubMed ID: 12784978 [TBL] [Abstract][Full Text] [Related]
24. Intraoperative hemostasis during kidney transplantation and the use collagen mesh dressing covered by fibrin glue (TachoComb). Pupka A; Chudoba P; Barć P; Kałuza G; Ruciński A; Janczak D; Pawłowski S; Szyber P Polim Med; 2003; 33(3):27-32. PubMed ID: 14696522 [TBL] [Abstract][Full Text] [Related]
25. Cost-benefit analysis of outcomes from the use of fibrin sealant for fixation of skin grafts in small-size burns compared to staples as historical controls: a retrospective review. Butts CC; Sahawneh J; Duffy A; Curtis R; Mishra N; Frotan MA; Hodge J; Luterman A; Gulati S Ann Plast Surg; 2015 Feb; 74(2):173-5. PubMed ID: 25590248 [TBL] [Abstract][Full Text] [Related]
26. The use of fibrin sealant in burn operations. Foster K Surgery; 2007 Oct; 142(4 Suppl):S50-4. PubMed ID: 18019939 [TBL] [Abstract][Full Text] [Related]
27. Protocol for an open randomised controlled trial investigating Fibrin Glue in Skin grafts for Skin cancer (FiGSS). Paw E; Vangaveti V; Zonta M; Heal C BMJ Open; 2022 Nov; 12(11):e064431. PubMed ID: 36351733 [TBL] [Abstract][Full Text] [Related]
28. Comparison of fibrin sealant and staples for attaching split-thickness autologous sheet grafts in patients with deep partial- or full-thickness burn wounds: a phase 1/2 clinical study. Gibran N; Luterman A; Herndon D; Lozano D; Greenhalgh DG; Grubbs L; Schofield N; Hantak E; Callahan JD; Schiestl N; Riina LH; J Burn Care Res; 2007; 28(3):401-8. PubMed ID: 17438504 [TBL] [Abstract][Full Text] [Related]
29. The role of topical thrombin in skin grafting. Ofodile FA; Sadana MK J Natl Med Assoc; 1991 May; 83(5):416-8. PubMed ID: 1875421 [TBL] [Abstract][Full Text] [Related]
30. The use of fibrin glue in skin grafts and tissue-engineered skin replacements: a review. Currie LJ; Sharpe JR; Martin R Plast Reconstr Surg; 2001 Nov; 108(6):1713-26. PubMed ID: 11711954 [TBL] [Abstract][Full Text] [Related]
31. Preparation of fibrin glue from single-donor fresh-frozen plasma. Dresdale A; Rose EA; Jeevanandam V; Reemtsma K; Bowman FO; Malm JR Surgery; 1985 Jun; 97(6):750-5. PubMed ID: 3873716 [TBL] [Abstract][Full Text] [Related]
32. [Value of fibrin glue in surgery of patients with severe burns]. Champsaur A; Goudeau MJ; Marichy J; Bouchard C; Petit P Ann Chir Plast Esthet; 1991; 36(5):394-8. PubMed ID: 1726386 [TBL] [Abstract][Full Text] [Related]
33. Hemostatic efficacy of a fibrin sealant-based topical agent in a femoral artery injury model: a randomized, blinded, placebo-controlled study. Jackson MR; Friedman SA; Carter AJ; Bayer V; Burge JR; MacPhee MJ; Drohan WN; Alving BM J Vasc Surg; 1997 Aug; 26(2):274-80. PubMed ID: 9279315 [TBL] [Abstract][Full Text] [Related]
34. Comparison of a new fibrin sealant with standard topical hemostatic agents. Schwartz M; Madariaga J; Hirose R; Shaver TR; Sher L; Chari R; Colonna JO; Heaton N; Mirza D; Adams R; Rees M; Lloyd D Arch Surg; 2004 Nov; 139(11):1148-54. PubMed ID: 15545559 [TBL] [Abstract][Full Text] [Related]
35. Clinical experience with fibrin glue for local bleeding control and sealing of vascular prostheses. Walterbusch G; Haverich A; Borst HG Thorac Cardiovasc Surg; 1982 Aug; 30(4):234-5. PubMed ID: 6182635 [TBL] [Abstract][Full Text] [Related]
36. Use of Fibrin Sealant for Split-Thickness Skin Grafts in Patients with Hand Burns: A Prospective Cohort Study. Kim Y; Kym D; Cho YS; Yoon J; Yim H; Hur J; Chun W Adv Skin Wound Care; 2018 Dec; 31(12):551-555. PubMed ID: 30371521 [TBL] [Abstract][Full Text] [Related]
37. Evaluation of a novel hemostatic device in an ovine parenchymal organ bleeding model of normal and impaired hemostasis. Turner AS; Parker D; Egbert B; Maroney M; Armstrong R; Powers N J Biomed Mater Res; 2002; 63(1):37-47. PubMed ID: 11787027 [TBL] [Abstract][Full Text] [Related]
38. A prospective randomized study comparing fibrin sealant to manual compression for the treatment of anastomotic suture-hole bleeding in expanded polytetrafluoroethylene grafts. Saha SP; Muluk S; Schenk W; Dennis JW; Ploder B; Grigorian A; Presch I; Goppelt A J Vasc Surg; 2012 Jul; 56(1):134-41. PubMed ID: 22633423 [TBL] [Abstract][Full Text] [Related]
39. A comparison of keratinocyte cell sprays with and without fibrin glue. Currie LJ; Martin R; Sharpe JR; James SE Burns; 2003 Nov; 29(7):677-85. PubMed ID: 14556725 [TBL] [Abstract][Full Text] [Related]