These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 8156677)

  • 1. Somatosensory evoked potential monitoring in the surgical treatment of acute, displaced acetabular fractures. Results of a prospective study.
    Helfet DL; Schmeling GJ
    Clin Orthop Relat Res; 1994 Apr; (301):213-20. PubMed ID: 8156677
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intraoperative evoked potential monitoring in acetabular surgery.
    Calder HB; Mast J; Johnstone C
    Clin Orthop Relat Res; 1994 Aug; (305):160-7. PubMed ID: 8050225
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intraoperative somatosensory evoked potential monitoring of pelvic and acetabular fractures.
    Vrahas M; Gordon RG; Mears DC; Krieger D; Sclabassi RJ
    J Orthop Trauma; 1992; 6(1):50-8. PubMed ID: 1556624
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative somatosensory evoked potential monitoring of the sciatic nerve: an animal model.
    Moed BR; Maxey JW; Minster GJ
    J Orthop Trauma; 1992; 6(1):59-65. PubMed ID: 1556625
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MR imaging of acetabular fractures: value in detecting femoral head injury, intraarticular fragments, and sciatic nerve injury.
    Potter HG; Montgomery KD; Heise CW; Helfet DL
    AJR Am J Roentgenol; 1994 Oct; 163(4):881-6. PubMed ID: 8092028
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Somatosensory evoked potential monitoring in the surgical management of acute acetabular fractures.
    Helfet DL; Hissa EA; Sergay S; Mast JW
    J Orthop Trauma; 1991; 5(2):161-6. PubMed ID: 1861191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Somatosensory-evoked potential monitored during total hip arthroplasty.
    Black DL; Reckling FW; Porter SS
    Clin Orthop Relat Res; 1991 Jan; (262):170-7. PubMed ID: 1984914
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Incidence of sciatic nerve injury in operatively treated acetabular fractures without somatosensory evoked potential monitoring.
    Middlebrooks ES; Sims SH; Kellam JF; Bosse MJ
    J Orthop Trauma; 1997 Jul; 11(5):327-9. PubMed ID: 9294795
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Upper-limb somatosensory evoked potential monitoring in lumbosacral spine surgery: a prognostic marker for position-related ulnar nerve injury.
    Chung I; Glow JA; Dimopoulos V; Walid MS; Smisson HF; Johnston KW; Robinson JS; Grigorian AA
    Spine J; 2009 Apr; 9(4):287-95. PubMed ID: 18684675
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of sciatic nerve compromise during total hip arthroplasty.
    Stone RG; Weeks LE; Hajdu M; Stinchfield FE
    Clin Orthop Relat Res; 1985 Dec; (201):26-31. PubMed ID: 4064413
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Iatrogenic nerve injury in acetabular fracture surgery: a comparison of monitored and unmonitored procedures.
    Haidukewych GJ; Scaduto J; Herscovici D; Sanders RW; DiPasquale T
    J Orthop Trauma; 2002 May; 16(5):297-301. PubMed ID: 11972071
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Complications of operative treatment of acetabular fractures].
    Zhu SW; Wang MY; Wu XB; Cao QY; Wu HH; Rong GW
    Zhonghua Wai Ke Za Zhi; 2003 May; 41(5):342-5. PubMed ID: 12892586
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intraoperative monitoring of motor pathways during operative fixation of acute acetabular fractures.
    Helfet DL; Anand N; Malkani AL; Heise C; Quinn TJ; Green DS; Burga S
    J Orthop Trauma; 1997 Jan; 11(1):2-6. PubMed ID: 8990024
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Injury of the sciatic nerve associated with acetabular fracture.
    Fassler PR; Swiontkowski MF; Kilroy AW; Routt ML
    J Bone Joint Surg Am; 1993 Aug; 75(8):1157-66. PubMed ID: 8354674
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Surgical treatment of acetabular fractures: outcome in a series of 60 consecutive cases].
    Glas PY; Fessy MH; Carret JP; Béjui-Hugues J
    Rev Chir Orthop Reparatrice Appar Mot; 2001 Oct; 87(6):529-38. PubMed ID: 11685143
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Personal experience with treatment of acetabular fractures].
    Pavelka T; Kortus J; Linhart M; Matĕjka J
    Acta Chir Orthop Traumatol Cech; 2004; 71(1):13-9. PubMed ID: 15069857
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multimodality monitoring of transcranial electric motor and somatosensory-evoked potentials during surgical correction of spinal deformity in patients with cerebral palsy and other neuromuscular disorders.
    DiCindio S; Theroux M; Shah S; Miller F; Dabney K; Brislin RP; Schwartz D
    Spine (Phila Pa 1976); 2003 Aug; 28(16):1851-5; discussion 1855-6. PubMed ID: 12923474
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multimodality intraoperative neurophysiologic monitoring findings during surgery for adult tethered cord syndrome: analysis of a series of 44 patients with long-term follow-up.
    Paradiso G; Lee GY; Sarjeant R; Hoang L; Massicotte EM; Fehlings MG
    Spine (Phila Pa 1976); 2006 Aug; 31(18):2095-102. PubMed ID: 16915095
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sciatic nerve monitoring during revision total hip arthroplasty.
    Kennedy WF; Byrne TF; Majid HA; Pavlak LL
    Clin Orthop Relat Res; 1991 Mar; (264):223-7. PubMed ID: 1847669
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spinal somatosensory evoked potential evaluation of acute nerve-root injury associated with pedicle-screw placement procedures: an experimental study.
    Jou IM; Hsu CC; Chern TC; Chen WY; Dau YC
    J Orthop Res; 2003 Mar; 21(2):365-72. PubMed ID: 12568971
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.