These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 8158104)

  • 21. Evaluation of a sensitive/less sensitive testing algorithm using the bioMérieux Vironostika-LS assay for detecting recent HIV-1 subtype B' or E infection in Thailand.
    Young CL; Hu DJ; Byers R; Vanichseni S; Young NL; Nelson R; Mock PA; Choopanya K; Janssen R; Mastro TD; Mei JV
    AIDS Res Hum Retroviruses; 2003 Jun; 19(6):481-6. PubMed ID: 12882657
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Efficacies of US Food and Drug Administration-licensed HIV-1-screening enzyme immunoassays for detecting antibodies to HIV-2.
    George JR; Rayfield MA; Phillips S; Heyward WL; Krebs JW; Odehouri K; Soudre R; De Cock KM; Schochetman G
    AIDS; 1990 Apr; 4(4):321-6. PubMed ID: 2350452
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Use of human immunodeficiency virus (HIV) type 1 and 2 recombinant strip immunoblot assay to resolve enzyme immunoassay anti-HIV-2-repeatably reactive samples after anti-HIV-1/2 combination enzyme immunoassay screening.
    Tobler LH; Kaufman E; Gefter N; Schable C; Busch MP
    Transfusion; 1997 Sep; 37(9):921-5. PubMed ID: 9308638
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Multicentre study for diagnostic evaluation of an assay for simultaneous detection of antibodies to HIV-1, HIV-2 and HIV-1 subtype 0 (HIV-0).
    Bachmann P; Beyer J; Brust S; Engelhardt W; Gürtler LG; Habermehl KO; Karakassopoulos A; Michl U; Mühlbacher A; Stöffler-Meilicke M
    Infection; 1995; 23(5):322-33. PubMed ID: 8557399
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Multisite evaluation of four anti-HIV-1/HIV-2 enzyme immunoassays. Australian HIV Test Evaluation Group.
    Silvester C; Healey DS; Cunningham P; Dax EM
    J Acquir Immune Defic Syndr Hum Retrovirol; 1995 Apr; 8(4):411-9. PubMed ID: 7882108
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Radioimmune western blotting in comparison with conventional western blotting, second and third generation ELISA assays for the serodiagnosis of HIV-1 infection.
    Portincasa P; Conti G; Zannino T; Visalli S; Chezzi C
    New Microbiol; 1994 Jul; 17(3):169-76. PubMed ID: 7968651
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Evaluation of an HIV screening assay kit for the combined detection of anti-HIV-1/2 antibodies and HIV p24 antigen].
    Shima T; Kondo M; Saito T; Kawata K; Ito A; Sakamoto M; Sagara H; Imai M
    Kansenshogaku Zasshi; 2001 Dec; 75(12):1014-24. PubMed ID: 11806135
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of an enzyme immunoassay for the combined detection of antibodies to HIV-1, HIV-2, HTLV-I and HTLV-II.
    McAlpine L; Parry JV; Tosswill JH
    AIDS; 1992 Apr; 6(4):387-91. PubMed ID: 1616635
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Anti-HIV testing by automated systems.
    McAlpine L; Parry JV; Mortimer PP
    Clin Diagn Virol; 1993 Oct; 1(4):225-32. PubMed ID: 15566736
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sensitivity and specificity of standard and rapid HIV-antibody tests evaluated by seroconversion and non-seroconversion low-titre panels.
    Kuun E; Brashaw M; Heyns AD
    Vox Sang; 1997; 72(1):11-5. PubMed ID: 9031494
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Evaluation of COBAS CORE anti-HIV-1/HIV-2 EIA DAGS for the detection of antibodies to HIV by COBAS CORE].
    Kodama T; Nada T; Yamamoto H; Morishita Y; Iinuma Y; Ichiyama S
    Rinsho Biseibutshu Jinsoku Shindan Kenkyukai Shi; 1999; 10(1):43-50. PubMed ID: 10415449
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Use of an acute seroconversion panel to evaluate a third-generation enzyme-linked immunoassay for detection of human immunodeficiency virus-specific antibodies relative to multiple other assays.
    Louie B; Pandori MW; Wong E; Klausner JD; Liska S
    J Clin Microbiol; 2006 May; 44(5):1856-8. PubMed ID: 16672422
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Modification of rapid human immunodeficiency virus (HIV) antibody assay protocols for detecting recent HIV seroconversion.
    Soroka SD; Granade TC; Candal D; Parekh BS
    Clin Diagn Lab Immunol; 2005 Aug; 12(8):918-21. PubMed ID: 16085908
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Performance of six commercial enzyme immunoassays and two alternative HIV-testing algorithms for the diagnosis of HIV-1 infection in Kisumu, Western Kenya.
    Zeh C; Oyaro B; Vandenhoudt H; Amornkul P; Kasembeli A; Bondo P; Mwaengo D; Thomas TK; Hart C; Laserson KF; Ondoa P; Nkengasong JN
    J Virol Methods; 2011 Sep; 176(1-2):24-31. PubMed ID: 21635920
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Field evaluation of alternative HIV testing strategy with a rapid immunobinding assay and an agglutination assay.
    Mitchell SW; Mboup S; Mingle J; Sambe D; Tukei P; Milenge K; Nyamongo J; Mubarak OK; Sankale JL; Hanson DS
    Lancet; 1991 Jun; 337(8753):1328-31. PubMed ID: 1674306
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.
    Tegbaru B; Messele T; Wolday D; Meles PH; Tesema D; Birhanu H; Tesfaye G; Bond KB; Martin R; Rayfield MA; Wuhib T; Fekadu M
    Ethiop Med J; 2004 Oct; 42(4):267-76. PubMed ID: 16122118
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of two serological tests for the identification of recent HIV infection: Vironostika HIV-1 Microelisa and BED capture enzyme immunoassay.
    Romero A; Martró E; González V; Matas L;
    Enferm Infecc Microbiol Clin; 2011; 29(7):553-5. PubMed ID: 21501904
    [No Abstract]   [Full Text] [Related]  

  • 38. An HIV seroconversion case: unequal performance of combined antigen/antibodies assays.
    Mukadi BK; Vandercam B; Bodeus M; Moreau M; Goubau P
    AIDS; 2002 Jan; 16(1):127-8. PubMed ID: 11741172
    [No Abstract]   [Full Text] [Related]  

  • 39. Synthetic-peptide-based enzyme-linked immunosorbent assay for screening human serum or plasma for antibodies to human immunodeficiency virus type 1 and type 2.
    Gonzalez L; Boyle RW; Zhang M; Castillo J; Whittier S; Della-Latta P; Clarke LM; George JR; Fang X; Wang JG; Hosein B; Wang CY
    Clin Diagn Lab Immunol; 1997 Sep; 4(5):598-603. PubMed ID: 9302212
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Frequency of human immunodeficiency virus (HIV) infection among contemporary anti-HIV-1 and anti-HIV-1/2 supplemental test-indeterminate blood donors. The Retrovirus Epidemiology Donor Study.
    Busch MP; Kleinman SH; Williams AE; Smith JW; Ownby HE; Laycock ME; Lee LL; Pau CP; Schreiber GB
    Transfusion; 1996 Jan; 36(1):37-44. PubMed ID: 8607151
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.