126 related articles for article (PubMed ID: 815917)
1. Potentiometric titration of 8-hydroxyquinoline with Cu(II) using Cu(II) sulphide-ion selective electrode.
Fayez M; El-Tarras M
Pharmazie; 1975 Dec; 30(12):799. PubMed ID: 815917
[No Abstract] [Full Text] [Related]
2. 8-hydroxyquinoline based neutral tripodal ionophore as a copper (II) selective electrode and the effect of remote substitutents on electrode properties.
Mittal SK; Kumar A; Gupta N; Kaur S; Kumar S
Anal Chim Acta; 2007 Feb; 585(1):161-70. PubMed ID: 17386661
[TBL] [Abstract][Full Text] [Related]
3. Indirect potentiometric titration of reducing carbohydrates. I. Using alkaline potassium mercuric bromide solution and sulphide selective electrode.
Shalaby A; el-Shehaby R; Aboul-Kheir A
Acta Pharm Hung; 1989 Sep; 59(5):201-4. PubMed ID: 2596300
[TBL] [Abstract][Full Text] [Related]
4. Determination of some cardiac drugs using an ionselective chloride electrode and a silver electrode.
Zommer-Urbańska S; Urbańska J
Pharmazie; 1985 Jun; 40(6):419-20. PubMed ID: 4034652
[TBL] [Abstract][Full Text] [Related]
5. Enhanced sensitivity for Cu(II) by a salicylidine-functionalized polysiloxane carbon paste electrode.
Abu-Shawish HM; Saadeh SM; Hussien AR
Talanta; 2008 Aug; 76(4):941-8. PubMed ID: 18656682
[TBL] [Abstract][Full Text] [Related]
6. Studies on the binding of copper to dopamine beta-monooxygenase and other proteins using the Cu2+ ion-selective electrode.
Syvertsen C; Gaustad R; Schrøder K; Ljones T
J Inorg Biochem; 1986 Jan; 26(1):63-76. PubMed ID: 3080550
[TBL] [Abstract][Full Text] [Related]
7. Determination of drugs containing fluorine with ion-selective electrode. Part 1: Synthetic glucocorticosteroids.
Hopkała H; Przyborowski L
Pharmazie; 1988 Jun; 43(6):422-3. PubMed ID: 3212030
[TBL] [Abstract][Full Text] [Related]
8. Kinetic model of the H(2)O(2)-SCN(-)-OH(-)-Cu(2+) oscillator and its application to the interpretation of the potentiometric responses of various inert electrodes monitoring the reaction course.
Wiśniewski A; Pekala K; Orlik M
J Phys Chem A; 2010 Jan; 114(1):183-90. PubMed ID: 20055515
[TBL] [Abstract][Full Text] [Related]
9. Poly(vinyl) chloride membrane copper-selective electrode based on 1-phenyl-2-(2-hydroxyphenylhydrazo)butane-1,3-dione.
Kopylovich MN; Mahmudov KT; Pombeiro AJ
J Hazard Mater; 2011 Feb; 186(2-3):1154-62. PubMed ID: 21177026
[TBL] [Abstract][Full Text] [Related]
10. Electroanalytical studies on Cu (II) ion-selective sensor of coated pyrolytic graphite electrodes based on N2S2O2 and N2S2O3 heterocyclic benzothiazol ligands.
Singh AK; Sahani MK; Bandi KR; Jain AK
Mater Sci Eng C Mater Biol Appl; 2014 Aug; 41():206-16. PubMed ID: 24907753
[TBL] [Abstract][Full Text] [Related]
11. Potentiometric and atomic absorption spectrometric determination of sulfonamides in pharmaceutic preparations.
Hassan SS; Eldesouki MH
J Assoc Off Anal Chem; 1981 Sep; 64(5):1158-63. PubMed ID: 7287612
[TBL] [Abstract][Full Text] [Related]
12. Potentiometric gas sensors for ammonia based on ion-selective electrodes for silver (1), copper (11) and mercury-(11).
Anfält T; Graneli A; Jagner D
Anal Chim Acta; 1975 Jun; 76(2):253-9. PubMed ID: 1147276
[No Abstract] [Full Text] [Related]
13. [All-purpose indicator electrode for potentiometric titrations of both cationic and anionic type drugs].
Yao SZ; Ma ML; Nie LH
Yao Xue Xue Bao; 1988 Mar; 23(3):189-95. PubMed ID: 3421107
[No Abstract] [Full Text] [Related]
14. Determination of parts-per-billion levels of hydrogen sulfide in air by potentiometric titration with a sulfide ion-selective electrode as an indicator.
Ehman DL
Anal Chem; 1976 May; 48(6):918-20. PubMed ID: 1267163
[No Abstract] [Full Text] [Related]
15. [IR and UV spectra of 2-chloro-4-nitrophenol and 5-NOQ].
Vladzimirskaia EV; Kvartnik VM
Farm Zh; 1975; (2):36-8. PubMed ID: 806467
[No Abstract] [Full Text] [Related]
16. Potentiometric determination of halothane.
Przyborowski L; Smajkiewicz A
Pol J Pharmacol Pharm; 1981; 33(5):533-7. PubMed ID: 7335557
[TBL] [Abstract][Full Text] [Related]
17. Construction of a new Cu2+ coated wire ion selective electrode based on 2-((2-(2-(2-(2-hydroxy-5-methoxybenzylidene amino)phenyl)disufanyl)phenylimino)methyl)-4-methoxyphenol Schiff base.
Shokrollahi A; Abbaspour A; Ghaedi M; Haghighi AN; Kianfar AH; Ranjbar M
Talanta; 2011 Mar; 84(1):34-41. PubMed ID: 21315894
[TBL] [Abstract][Full Text] [Related]
18. [Ionization constants and stability constants of the copper(II)-complexes of some amino acids and their sulfur-containing analogs].
Hermann P; Lemke K
Hoppe Seylers Z Physiol Chem; 1968 Apr; 349(4):390-4. PubMed ID: 5652055
[No Abstract] [Full Text] [Related]
19. [COMPARATIVE STUDY OF VARIOUS ELECTRODE SYSTEMS IN NON-AQUEOUS SOLVENTS: II. POTENTIOMETRIC DETERMINATIONS IN ACETIC ACID, CHLOROFORM, ACETONITRILE AND ACETONE].
PELLERIN F; DEMAY D
Ann Pharm Fr; 1964 Apr; 22():307-12. PubMed ID: 14197757
[No Abstract] [Full Text] [Related]
20. Electroanalytical and naked eye determination of Cu(2+) ion in various environmental samples using 5-amino-1,3,4-thiadiazole-2-thiol based Schiff bases.
Bandi KR; Singh AK; Upadhyay A
Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():149-57. PubMed ID: 24268244
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]