These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 8161430)

  • 21. Somatosensory evoked potential monitoring of temporary middle cerebral artery occlusion during aneurysm operation.
    Mooij JJ; Buchthal A; Belopavlovic M
    Neurosurgery; 1987 Oct; 21(4):492-6. PubMed ID: 3683782
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Monitoring of cortical blood flow during temporary arterial occlusion in aneurysm surgery by the thermal diffusion method.
    Ohmoto T; Nagao S; Mino S; Fujiwara T; Honma Y; Ito T; Ohkawa M
    Neurosurgery; 1991 Jan; 28(1):49-54; discussion 54-5. PubMed ID: 1994281
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Variations in regional cerebral blood flow investigated by single photon emission computed tomography with technetium-99m-d, l-hexamethylpropyleneamineoxime = l-h during temporary clipping in intracranial aneurysm surgery: preliminary results.
    Medina M; Melcarne A; Musso C; Ettorre F; Bellotti C; Papaleo A; Camuzzini G
    Neurosurgery; 1993 Sep; 33(3):441-9; discussion 449-50. PubMed ID: 8413876
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Transcranial motor evoked potentials monitoring for cerebral aneurysm surgery].
    Yamashita S; Sasaki O; Suzuki K; Takao T; Nakamura K; Koike T
    No Shinkei Geka; 2013 Jan; 41(1):15-24. PubMed ID: 23269251
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anesthetic Challenges in the Management of Distal Posterior Cerebral Artery Aneurysm for Surgical Clipping: A Report of 2 Cases.
    Muthachen NR; Sethuraman M
    J Neurosurg Anesthesiol; 2017 Jul; 29(3):370-372. PubMed ID: 27271236
    [No Abstract]   [Full Text] [Related]  

  • 26. [Intraoperative microvascular Doppler ultrasonography monitoring in intracranial aneurysm surgery].
    Tong J; Wang S; Zhao YL; Zhao JZ
    Zhonghua Yi Xue Za Zhi; 2007 Apr; 87(13):881-4. PubMed ID: 17650396
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Intraoperative monitoring of substrate delivery during aneurysm and hematoma surgery: initial experience in 16 patients.
    Doppenberg EM; Watson JC; Broaddus WC; Holloway KL; Young HF; Bullock R
    J Neurosurg; 1997 Dec; 87(6):809-16. PubMed ID: 9384388
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Monitoring of direct cortical responses during temporary arterial occlusion at aneurysm surgery.
    Fujita S; Kawaguchi T
    Acta Neurochir (Wien); 1989; 101(1-2):23-8. PubMed ID: 2603762
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Electrophysiological (EEG-SSEP) monitoring during middle cerebral aneurysm surgery.
    Parenti G; Marconi F; Fiori L
    J Neurosurg Sci; 1996; 40(3-4):195-205. PubMed ID: 9165427
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Temporary arterial occlusion during anterior communicating or anterior cerebral artery aneurysm operation under tibial nerve somatosensory evoked potential monitoring.
    Sako K; Nakai H; Kawata Y; Takizawa K; Satho M; Yonemasu Y
    Surg Neurol; 1998 Mar; 49(3):316-22; discussion 322-3. PubMed ID: 9508122
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evoked potential monitoring and temporary clipping in cerebral aneurysm surgery.
    Buchthal A; Belopavlovic M; Mooij JJ
    Acta Neurochir (Wien); 1988; 93(1-2):28-36. PubMed ID: 3414414
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Microscope-integrated near-infrared indocyanine green videoangiography during surgery of intracranial aneurysms: the Helsinki experience.
    Dashti R; Laakso A; Niemelä M; Porras M; Hernesniemi J
    Surg Neurol; 2009 May; 71(5):543-50; discussion 550. PubMed ID: 19328531
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Use of STA-MCA anastomosis for clipping of giant middle cerebral artery aneurysm--case report.
    Kimura M; Tanaka A; Matsuno H; Nagata S
    Neurol Med Chir (Tokyo); 1993 Nov; 33(11):774-8. PubMed ID: 7506816
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Ischemia changes and tolerance ratio of evoked potential monitoring in intracranial aneurysm surgery.
    Kang D; Yao P; Wu Z; Yu L
    Clin Neurol Neurosurg; 2013 May; 115(5):552-6. PubMed ID: 22795547
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Temporary clipping during early operation for ruptured aneurysm: preliminary report.
    Ljunggren B; Säveland H; Brandt L; Kågström E; Rehncrona S; Nilsson PE
    Neurosurgery; 1983 May; 12(5):525-30. PubMed ID: 6866234
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Reconstruction of the MCA bifurcation after excision of a giant aneurysm. Technical note.
    Bojanowski WM; Spetzler RF; Carter LP
    J Neurosurg; 1988 Jun; 68(6):974-7. PubMed ID: 3373294
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Somatosensory evoked potentials in cerebral aneurysm surgery.
    Buchthal A; Belopavlovic M
    Eur J Anaesthesiol; 1992 Nov; 9(6):493-7. PubMed ID: 1425619
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cortical blood flow during craniotomy for aneurysms.
    Carter LP; Erspamer R; White WL; Yamagata S
    Surg Neurol; 1982 Mar; 17(3):204-8. PubMed ID: 6210971
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Temporary clipping and cerebral blood flow in patients with cerebral aneurysms].
    Asaturian GA; Semeniutin VB; Maslennikova LS; Panutsev VS; Sergienko SK
    Zh Vopr Neirokhir Im N N Burdenko; 2006; (3):18-21; discussion 21-3. PubMed ID: 17125074
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cortical thermal clearance as a predictor of imminent neurological deterioration.
    Choksey MS
    Cerebrovasc Brain Metab Rev; 1996; 8(3):230-71. PubMed ID: 8870976
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.