  • 1. Comparative study of the hydrodynamic function of the size 19mm and 21mm St. Jude Medical Hemodynamic Plus Bileaflet Heart valves.
    Fisher J
    J Heart Valve Dis; 1994 Jan; 3(1):75-80. PubMed ID: 8162222
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves.
    Reul H; van Son JA; Steinseifer U; Schmitz B; Schmidt A; Schmitz C; Rau G
    J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The hemodynamic effects of mechanical prosthetic valve type and orientation on fluid mechanical energy loss and pressure drop in in vitro models of ventricular hypertrophy.
    Travis BR; Heinrich RS; Ensley AE; Gibson DE; Hashim S; Yoganathan AP
    J Heart Valve Dis; 1998 May; 7(3):345-54. PubMed ID: 9651851
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Early in vivo experience with the Hemodynamic Plus St. Jude Medical heart valves in patients with narrowed aortic annulus.
    Carrel T; Zingg U; Jenni R; Aeschbacher B; Turina MI
    Ann Thorac Surg; 1996 May; 61(5):1418-22. PubMed ID: 8633952
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparative study of mechanical heart valves for implantation in mitral position].
    Heiliger R; Lambertz H; Geks J; Mittermayer C
    Herz; 1987 Dec; 12(6):405-12. PubMed ID: 3428845
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative study of the hydrodynamic function of six size 19 mm bileaflet heart valves.
    Fisher J
    Eur J Cardiothorac Surg; 1995; 9(12):692-5 discussion 695-6. PubMed ID: 8703490
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro evaluation of the long-body On-X bileaflet heart valve.
    Hwang NH; Reul H; Reinhard P
    J Heart Valve Dis; 1998 Sep; 7(5):561-8. PubMed ID: 9793857
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study.
    Jahandardoost M; Fradet G; Mohammadi H
    Proc Inst Mech Eng H; 2016 Mar; 230(3):175-90. PubMed ID: 26786673
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro.
    Jennings LM; Butterfield M; Walker PG; Watterson KG; Fisher J
    J Heart Valve Dis; 2001 Mar; 10(2):269-75. PubMed ID: 11297215
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative study of the hydrodynamic function of the CarboMedics valve.
    Butterfield M; Fisher J; Davies GA; Spyt TJ
    Ann Thorac Surg; 1991 Oct; 52(4):815-20. PubMed ID: 1929635
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Early experience with the new Masters series of St. Jude Medical heart valve: in vivo hemodynamic and clinical results in patients with narrowed aortic annulus.
    Zingg U; Aeschbacher B; Seiler C; Althaus U; Carrel T
    J Heart Valve Dis; 1997 Sep; 6(5):535-41. PubMed ID: 9330177
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel pulse duplicator system: evaluation of different valve prostheses.
    Haaf P; Steiner M; Attmann T; Pfister G; Cremer J; Lutter G
    Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemodynamics of high-performance bileaflet valves: comparison to simulated clinical Doppler measurements.
    Dohmen G; Schmitz C; Schmitz-Rode T; Steinseifer U; Autschbach R
    J Heart Valve Dis; 2006 Jul; 15(4):549-56. PubMed ID: 16901053
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hemodynamic performance of the new St. Jude Medical Epic Supra porcine bioprosthesis in comparison to the Medtronic Mosaic on the basis of patient annulus diameter.
    Ruzicka DJ; Eichinger WB; Hettich IM; Bleiziffer S; Bauernschmitt R; Lange R
    J Heart Valve Dis; 2008 Jul; 17(4):426-33; discussion 434. PubMed ID: 18751473
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The new St. Jude Medical regent mechanical heart valve: laboratory measurements of hydrodynamic performance.
    Walker DK; Brendzel AM; Scotten LN
    J Heart Valve Dis; 1999 Nov; 8(6):687-96. PubMed ID: 10616249
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of hemodynamic performance of Medtronic Hall 21 mm versus St. Jude Medical 23 mm prostheses in pigs.
    Kleine P; Abdel-Rahman U; Klesius AA; Scherer M; Simon A; Moritz A
    J Heart Valve Dis; 2002 Nov; 11(6):857-63. PubMed ID: 12479289
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pulsatile flow past St. Jude Medical bileaflet valve. An in vitro study.
    Chandran KB
    J Thorac Cardiovasc Surg; 1985 May; 89(5):743-9. PubMed ID: 3990323
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fluid dynamics of the CarboMedics kinetic bileaflet prosthetic heart valve.
    Baldwin JT; Campbell A; Luck C; Ogilvie W; Sauter J
    Eur J Cardiothorac Surg; 1997 Feb; 11(2):287-92. PubMed ID: 9080157
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In-vitro hemodynamics of stented bioprosthetic heart valves in the tilted implantation position.
    Babin-Ebell J; Sievers HH; Misfeld M; Runge M; Vogt PR; Scharfschwerdt M
    J Heart Valve Dis; 2008 Sep; 17(5):566-70. PubMed ID: 18980091
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Small aortic annulus: the hydrodynamic performances of 5 commercially available tissue valves.
    Gerosa G; Tarzia V; Rizzoli G; Bottio T
    J Thorac Cardiovasc Surg; 2006 May; 131(5):1058-64. PubMed ID: 16678590
    [TBL] [Abstract][Full Text] [Related]  