123 related articles for article (PubMed ID: 8163761)

  • 1. A new paediatric metabolic monitor.
    Weyland W; Weyland A; Fritz U; Redecker K; Ensink FB; Braun U
    Intensive Care Med; 1994; 20(1):51-7. PubMed ID: 8163761
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro validation of a metabolic monitor for gas exchange measurements in ventilated neonates.
    Behrends M; Kernbach M; Bräuer A; Braun U; Peters J; Weyland W
    Intensive Care Med; 2001 Jan; 27(1):228-35. PubMed ID: 11280640
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A ventilator with an integrated gas-exchange monitoring function.
    Weyland W; Weyland A; Gefeller O; al-Soufi S; Sydow M; Braun U
    Crit Care Med; 1994 May; 22(5):864-71. PubMed ID: 8181298
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Validation of the gas exchange monitoring function of the Engström Elvira respirator].
    Weyland W; van der Horst J; Weyland A; Reiter M; Freiboth K; Braun U
    Anaesthesist; 1992 Apr; 41(4):210-7. PubMed ID: 1590577
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients.
    Tissot S; Delafosse B; Bertrand O; Bouffard Y; Viale JP; Annat G
    Intensive Care Med; 1995 Feb; 21(2):149-53. PubMed ID: 7775696
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A multipatient mass spectrometer based system for the measurement of metabolic gas exchange in artificially ventilated intensive care patients.
    Roberts MJ; Boustred ML; Hinds CJ
    Intensive Care Med; 1983; 9(6):339-43. PubMed ID: 6418783
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a portable indirect calorimetry system for measurement of energy expenditure in sick preterm infants.
    Shortland GJ; Fleming PJ; Walter JH
    Arch Dis Child; 1992 Oct; 67(10 Spec No):1207-11. PubMed ID: 1444562
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of gas exchange in intensive care: laboratory and clinical validation of a new device.
    Takala J; Keinänen O; Väisänen P; Kari A
    Crit Care Med; 1989 Oct; 17(10):1041-7. PubMed ID: 2676345
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Device for the Quantification of Oxygen Consumption and Caloric Expenditure in the Neonatal Range.
    Nachman E; Clemensen P; Santos K; Cole AR; Polizzotti BD; Hofmann G; Leeman KT; van den Bosch SJ; Kheir JN
    Anesth Analg; 2018 Jul; 127(1):95-104. PubMed ID: 29505450
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Carbon dioxide elimination and oxygen consumption in mechanically ventilated children.
    Smallwood CD; Walsh BK; Bechard LJ; Mehta NM
    Respir Care; 2015 May; 60(5):718-23. PubMed ID: 25550526
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vitro evaluation of a compact metabolic measurement instrument.
    Weissman C; Sardar A; Kemper M
    JPEN J Parenter Enteral Nutr; 1990; 14(2):216-21. PubMed ID: 2112632
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous non-invasive monitoring of energy expenditure, oxygen consumption and alveolar ventilation during controlled ventilation: validation in an oxygen consuming lung model.
    Holk K; Einarsson SG; Svensson KL; Bengtson JP; Stenqvist O
    Acta Anaesthesiol Scand; 1996 May; 40(5):530-7. PubMed ID: 8792881
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of oxygen uptake and carbon dioxide elimination using the bymixer: validation in a metabolic lung simulator.
    Rosenbaum A; Kirby C; Breen PH
    Anesthesiology; 2004 Jun; 100(6):1427-37. PubMed ID: 15166562
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.
    Chang AC; Kulik TJ; Hickey PR; Wessel DL
    Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technical and methodologic considerations for performance of indirect calorimetry in ventilated and nonventilated preterm infants.
    Thureen PJ; Phillips RE; DeMarie MP; Hoffenberg A; Bronstein MN; Spedale SB; Hay WW
    Crit Care Med; 1997 Jan; 25(1):171-80. PubMed ID: 8989195
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Methods to validate the accuracy of an indirect calorimeter in the in-vitro setting.
    Oshima T; Ragusa M; Graf S; Dupertuis YM; Heidegger CP; Pichard C
    Clin Nutr ESPEN; 2017 Dec; 22():71-75. PubMed ID: 29415838
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metabolic monitor.
    Meriläinen PT
    Int J Clin Monit Comput; 1987; 4(3):167-77. PubMed ID: 3116131
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A validation and comparison study of two metabolic monitors.
    Phang PT; Rich T; Ronco J
    JPEN J Parenter Enteral Nutr; 1990; 14(3):259-61. PubMed ID: 2112638
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of FiO
    Ferreruela M; Raurich JM; Llompart-Pou JA; Colomar A; Ayestarán I
    Med Intensiva; 2017 Nov; 41(8):461-467. PubMed ID: 28283325
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical and clinical testing of a computerized indirect calorimeter for use in mechanically ventilated neonates.
    Mayfield SR
    Am J Clin Nutr; 1991 Jul; 54(1):30-4. PubMed ID: 1905477
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.