125 related articles for article (PubMed ID: 8168316)
21. Axial cyclic behavior of the bone-screw interface.
Inceoğlu S; Ehlert M; Akbay A; McLain RF
Med Eng Phys; 2006 Nov; 28(9):888-93. PubMed ID: 16458568
[TBL] [Abstract][Full Text] [Related]
22. Decreasing strength of bone allograft after recovery and preservation.
Kayurapan A; Aresanasuwan T; Waikakul S
J Med Assoc Thai; 2009 Sep; 92 Suppl5():S76-80. PubMed ID: 19894334
[TBL] [Abstract][Full Text] [Related]
23. Stress relaxation at the bone-pedicle screw interface in human bone.
Inceoğlu S; Akbay A; McLain RF
Spine (Phila Pa 1976); 2006 May; 31(12):1321-6. PubMed ID: 16721293
[TBL] [Abstract][Full Text] [Related]
24. A comparison of pullout strength for pedicle screws of different designs: a study using tapped and untapped pilot holes.
Pfeiffer FM; Abernathie DL; Smith DE
Spine (Phila Pa 1976); 2006 Nov; 31(23):E867-70. PubMed ID: 17077722
[TBL] [Abstract][Full Text] [Related]
25. Biomechanical study of pedicle screw fixation in severely osteoporotic bone.
Cook SD; Salkeld SL; Stanley T; Faciane A; Miller SD
Spine J; 2004; 4(4):402-8. PubMed ID: 15246300
[TBL] [Abstract][Full Text] [Related]
26. Bicortical screw fixation of distal fibula fractures with a lateral plate: an anatomic and biomechanical study of a new technique.
Milner BF; Mercer D; Firoozbakhsh K; Larsen K; Decoster TA; Miller RA
J Foot Ankle Surg; 2007; 46(5):341-7. PubMed ID: 17761318
[TBL] [Abstract][Full Text] [Related]
27. Analysis of screw pullout strength: a function of screw orientation in subtalar joint arthrodesis.
McGlamry MC; Robitaille MF
J Foot Ankle Surg; 2004; 43(5):277-84. PubMed ID: 15480401
[TBL] [Abstract][Full Text] [Related]
28. Effect of freeze-drying and gamma irradiation on the mechanical properties of human cancellous bone.
Cornu O; Banse X; Docquier PL; Luyckx S; Delloye C
J Orthop Res; 2000 May; 18(3):426-31. PubMed ID: 10937629
[TBL] [Abstract][Full Text] [Related]
29. Screw design alters the effects of stress relaxation on pullout.
Inceoğlu S; Kilinçer C; McLain RF
Biomed Mater Eng; 2008; 18(2):53-60. PubMed ID: 18408256
[TBL] [Abstract][Full Text] [Related]
30. Tibial fixation of bone-patellar tendon-bone grafts in anterior cruciate ligament reconstruction: a cadaveric study of bovine bone screw and biodegradable interference screw.
Zheng N; Price CT; Indelicato PA; Gao B
Am J Sports Med; 2008 Dec; 36(12):2322-7. PubMed ID: 18765676
[TBL] [Abstract][Full Text] [Related]
31. Augmentation of anterior transvertebral screws using threaded teflon anchoring.
Korovessis PG; Deligianni D; Stamatakis M; Missirlis Y
J Spinal Disord; 1998 Aug; 11(4):300-6. PubMed ID: 9726298
[TBL] [Abstract][Full Text] [Related]
32. Anterior fixation in the osteoporotic spine: cut-out and pullout characteristics of implants.
Ferguson SJ; Winkler F; Nolte LP
Eur Spine J; 2002 Dec; 11(6):527-34. PubMed ID: 12522709
[TBL] [Abstract][Full Text] [Related]
33. Effects of angle and laminectomy on triangulated pedicle screws.
Kilinçer C; Inceoglu S; Sohn MJ; Ferrara LA; Benzel EC
J Clin Neurosci; 2007 Dec; 14(12):1186-91. PubMed ID: 17719788
[TBL] [Abstract][Full Text] [Related]
34. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses.
Chao CK; Hsu CC; Wang JL; Lin J
J Spinal Disord Tech; 2008 Apr; 21(2):130-8. PubMed ID: 18391719
[TBL] [Abstract][Full Text] [Related]
35. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
Clin Biomech (Bristol, Avon); 2009 May; 24(4):379-84. PubMed ID: 19231049
[TBL] [Abstract][Full Text] [Related]
36. Pullout strengths of cannulated and noncannulated cancellous bone screws.
Thompson JD; Benjamin JB; Szivek JA
Clin Orthop Relat Res; 1997 Aug; (341):241-9. PubMed ID: 9269180
[TBL] [Abstract][Full Text] [Related]
37. Comparison of pullout strength of small-diameter cannulated and solid-core screws.
Kissel CG; Friedersdorf SC; Foltz DS; Snoeyink T
J Foot Ankle Surg; 2003; 42(6):334-8. PubMed ID: 14688774
[TBL] [Abstract][Full Text] [Related]
38. Interference screw divergence in femoral tunnel fixation during endoscopic anterior cruciate ligament reconstruction using hamstring grafts.
Miller CM; Tibone JE; Hewitt M; Kharrazi FD; Elattrache NS
Arthroscopy; 2002; 18(5):510-4. PubMed ID: 11987062
[TBL] [Abstract][Full Text] [Related]
39. Cortical screw pullout strength and effective shear stress in synthetic third generation composite femurs.
Zdero R; Rose S; Schemitsch EH; Papini M
J Biomech Eng; 2007 Apr; 129(2):289-93. PubMed ID: 17408335
[TBL] [Abstract][Full Text] [Related]
40. Comparison of pullout strength of resorbable screws and titanium screws in human cadaveric laryngeal cartilage.
Windham BP; Jordan JR; Parsell DE
Laryngoscope; 2007 Nov; 117(11):1964-8. PubMed ID: 17767085
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]