These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 8176572)

  • 1. Effect of insulated skin probes to increase skin-to-environmental temperature gradients of preterm infants cared for in convective incubators.
    Dollberg S; Atherton HD; Sigda M; Acree CM; Hoath SB
    J Pediatr; 1994 May; 124(5 Pt 1):799-801. PubMed ID: 8176572
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Environmental temperature control in very low birth weight infants (less than 1000 grams) cared for in double-walled incubators.
    Chessex P; Blouet S; Vaucher J
    J Pediatr; 1988 Aug; 113(2):373-80. PubMed ID: 3397804
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Head insulation for premature infants in servocontrolled incubators and radiant warmers.
    Templeman MC; Bell EF
    Am J Dis Child; 1986 Sep; 140(9):940-2. PubMed ID: 3740003
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Air versus skin temperature servocontrol of infant incubators.
    Bell EF; Rios GR
    J Pediatr; 1983 Dec; 103(6):954-9. PubMed ID: 6644435
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preterm infant thermal care: differing thermal environments produced by air versus skin servo-control incubators.
    Thomas KA; Burr R
    J Perinatol; 1999 Jun; 19(4):264-70. PubMed ID: 10685236
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A double-walled incubator alters the partition of body heat loss of premature infants.
    Bell EF; Rios GR
    Pediatr Res; 1983 Feb; 17(2):135-40. PubMed ID: 6402753
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Infant incubators and radiant warmers.
    Bell EF
    Early Hum Dev; 1983 Oct; 8(3-4):351-75. PubMed ID: 6641579
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of low humidity on small premature infants in servocontrol incubators. I. Decrease in rectal temperature.
    Belgaumkar TK; Scott K
    Biol Neonate; 1975; 26(5-6):337-47. PubMed ID: 1174595
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Measuring lateral skin temperature profile of premature infants in incubators with thermography].
    Frankenberger RT; Bussmann O; Nahm W; Konecny E; Gortner L
    Biomed Tech (Berl); 1998 Jun; 43(6):174-8. PubMed ID: 9677758
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Additional double-wall roof in single-wall, closed, convective incubators: Impact on body heat loss from premature infants and optimal adjustment of the incubator air temperature.
    Delanaud S; Decima P; Pelletier A; Libert JP; Stephan-Blanchard E; Bach V; Tourneux P
    Med Eng Phys; 2016 Sep; 38(9):922-8. PubMed ID: 27387899
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Relative efficacy of radiant and convective heat in incubators in producing thermoneutrality for the premature.
    Leblanc MH
    Pediatr Res; 1984 May; 18(5):425-8. PubMed ID: 6728569
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of temporal artery, mid-forehead skin and axillary temperature recordings in preterm infants <1500 g of birthweight.
    Duran R; Vatansever U; Acunaş B; Süt N
    J Paediatr Child Health; 2009; 45(7-8):444-7. PubMed ID: 19712180
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of different phototherapy lights on incubator characteristics and dynamics under three modes of servocontrol.
    Dollberg S; Atherton HD; Hoath SB
    Am J Perinatol; 1995 Jan; 12(1):55-60. PubMed ID: 7710580
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A clinical comparison of radiant warmer and incubator care for preterm infants from birth to 1800 grams.
    Meyer MP; Payton MJ; Salmon A; Hutchinson C; de Klerk A
    Pediatrics; 2001 Aug; 108(2):395-401. PubMed ID: 11483805
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous measurement of core body temperature in preterm infants.
    Dollberg S; Rimon A; Atherton HD; Hoath SB
    Am J Perinatol; 2000; 17(5):257-64. PubMed ID: 11110344
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Measuring skin temperature in premature infants. Comparison of infrared telethermography and electric contact thermometry].
    Hanssler L; Breukmann H
    Klin Padiatr; 1992; 204(5):355-8. PubMed ID: 1405422
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transfer of preterm infants from incubator to open cot at lower versus higher body weight.
    New K; Flenady V; Davies MW
    Cochrane Database Syst Rev; 2004; (2):CD004214. PubMed ID: 15106242
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement and Control of an Incubator Temperature by Using Conventional Methods and Fiber Bragg Grating (FBG) Based Temperature Sensors.
    Burunkaya M; Yucel M
    J Med Syst; 2020 Aug; 44(10):178. PubMed ID: 32856101
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A mean body temperature of 37°C for incubated preterm infants is associated with lower energy costs in the first 11 days of life.
    Degorre C; Décima P; Dégrugilliers L; Ghyselen L; Bach V; Libert JP; Tourneux P
    Acta Paediatr; 2015 Jun; 104(6):581-8. PubMed ID: 25661668
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preterm infant thermal responses to caregiving differ by incubator control mode.
    Thomas KA
    J Perinatol; 2003 Dec; 23(8):640-5. PubMed ID: 14647160
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.