These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

77 related articles for article (PubMed ID: 8181278)

  • 1. Timing is everything--or is it?
    Stock MC
    Crit Care Med; 1994 May; 22(5):730-1. PubMed ID: 8181278
    [No Abstract]   [Full Text] [Related]  

  • 2. Spontaneous breathing trials: should we use automatic tube compensation?
    Tanios MA; Epstein SK
    Respir Care; 2010 May; 55(5):640-2. PubMed ID: 20420738
    [No Abstract]   [Full Text] [Related]  

  • 3. Automatic tube compensation during weaning from mechanical ventilation: evidence and clinical implications.
    Unoki T; Serita A; Grap MJ
    Crit Care Nurse; 2008 Aug; 28(4):34-42; quiz 43. PubMed ID: 18669705
    [No Abstract]   [Full Text] [Related]  

  • 4. Effects of the components of positive airway pressure on work of breathing during bronchospasm.
    Miro AM; Pinsky MR; Rogers PL
    Crit Care; 2004 Apr; 8(2):R72-81. PubMed ID: 15025781
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Negative-impedance ventilation (NIV).
    Poon CS
    Am J Respir Crit Care Med; 1994 Jan; 149(1):268. PubMed ID: 8111592
    [No Abstract]   [Full Text] [Related]  

  • 6. Advanced modes of mechanical ventilation: implications for practice.
    Rose L; Ed A
    AACN Adv Crit Care; 2006; 17(2):145-58; quiz 159-160. PubMed ID: 16767015
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients.
    Knight DJ; Moppett IK; Hardman JG
    Eur J Anaesthesiol; 2003 Nov; 20(11):932; author reply 933. PubMed ID: 14649348
    [No Abstract]   [Full Text] [Related]  

  • 8. [Physiological effects of spontaneous breathing in positive pressure ventilation].
    Xia JG; Zhan QY
    Zhonghua Jie He He Hu Xi Za Zhi; 2007 Oct; 30(10):782-4. PubMed ID: 18218214
    [No Abstract]   [Full Text] [Related]  

  • 9. Partitioning the work-sparing effects of partial ventilatory support in airflow obstruction.
    Marini JJ
    Crit Care; 2004 Apr; 8(2):101-2. PubMed ID: 15025768
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pressure support ventilation: reducing the work of breathing during weaning.
    Pierce JD; Wiggins SA; Plaskon C; Glass C
    Dimens Crit Care Nurs; 1993; 12(6):282-90; quiz 294. PubMed ID: 10838991
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of breathing pattern on the pressure-time product calculation.
    Natalini G; Marchesini M; Tessadrelli A; Rosano A; Candiani A; Bernardini A
    Acta Anaesthesiol Scand; 2004 May; 48(5):642-7. PubMed ID: 15101863
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical effects of airway humidification devices in difficult to wean patients.
    Girault C; Breton L; Richard JC; Tamion F; Vandelet P; Aboab J; Leroy J; Bonmarchand G
    Crit Care Med; 2003 May; 31(5):1306-11. PubMed ID: 12771595
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Bicore pulmonary monitor. A device to assess the work of breathing while weaning from mechanical ventilation.
    Petros AJ; Lamond CT; Bennett D
    Anaesthesia; 1993 Nov; 48(11):985-8. PubMed ID: 8250198
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pressure-support ventilation: still a simple mode?
    Brochard L
    Intensive Care Med; 1996 Nov; 22(11):1137-8. PubMed ID: 9120101
    [No Abstract]   [Full Text] [Related]  

  • 15. [The effect of positive end-expiratory pressure on respiratory biomechanics in bronchial asthma].
    Dukov LG; Efremushkina AA; Mal'chenko TD; Golovina NV
    Ter Arkh; 1997; 69(3):42-5. PubMed ID: 9229828
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Respiration can be monitored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory mode.
    Nilsson L; Johansson A; Kalman S
    Acta Anaesthesiol Scand; 2005 Sep; 49(8):1157-62. PubMed ID: 16095458
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome: a comparison between volume and pressure-regulated breathing modes.
    Kallet RH; Campbell AR; Dicker RA; Katz JA; Mackersie RC
    Respir Care; 2005 Dec; 50(12):1623-31. PubMed ID: 16318643
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dynamic respiratory mechanics measurements for optimization of ventilator settings in acute lung injury.
    Habib RH; Assaly RA
    Crit Care Med; 2007 Jul; 35(7):1806-7; author reply 1807-8. PubMed ID: 17581388
    [No Abstract]   [Full Text] [Related]  

  • 19. Effect of different inspiratory rise time and cycling off criteria during pressure support ventilation in patients recovering from acute lung injury.
    Chiumello D; Pelosi P; Taccone P; Slutsky A; Gattinoni L
    Crit Care Med; 2003 Nov; 31(11):2604-10. PubMed ID: 14605531
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of different release times on spontaneous breathing pattern during airway pressure release ventilation.
    Neumann P; Golisch W; Strohmeyer A; Buscher H; Burchardi H; Sydow M
    Intensive Care Med; 2002 Dec; 28(12):1742-9. PubMed ID: 12447517
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.