These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 8186490)

  • 1. Interference of glucose sensing by amino acids.
    Yao SJ; Xu W; Day TL; Patzer JF; Wolfson SK
    ASAIO J; 1994; 40(1):33-40. PubMed ID: 8186490
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electrochemical behavior of L-cysteine and its detection at carbon nanotube electrode modified with platinum.
    Fei S; Chen J; Yao S; Deng G; He D; Kuang Y
    Anal Biochem; 2005 Apr; 339(1):29-35. PubMed ID: 15766706
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrochemical glucose sensing at low potentials.
    Wolfson SK; Chan LT; Krupper MA; Yao SJ
    Biomed Biochim Acta; 1989; 48(11-12):919-24. PubMed ID: 2636837
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nonenzymatic electrochemical glucose sensor based on nanoporous PtPb networks.
    Wang J; Thomas DF; Chen A
    Anal Chem; 2008 Feb; 80(4):997-1004. PubMed ID: 18197691
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructures.
    Curulli A; Valentini F; Orlanduci S; Terranova ML; Palleschi G
    Biosens Bioelectron; 2004 Dec; 20(6):1223-32. PubMed ID: 15556371
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The coated wire electrode glucose sensor.
    Wilkins ES; Wilkins MG
    Horm Metab Res Suppl; 1988; 20():50-5. PubMed ID: 3074038
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Amperometric glucose biosensor based on multilayer films via layer-by-layer self-assembly of multi-wall carbon nanotubes, gold nanoparticles and glucose oxidase on the Pt electrode.
    Wu BY; Hou SH; Yin F; Zhao ZX; Wang YY; Wang XS; Chen Q
    Biosens Bioelectron; 2007 Jun; 22(12):2854-60. PubMed ID: 17212983
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of sugar, amino acid, metal ion, and NaCl on model Maillard reaction under pH control.
    Kwak EJ; Lim SI
    Amino Acids; 2004 Aug; 27(1):85-90. PubMed ID: 15309575
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hepatic blood flow changes following intravenous infusion of various single amino acids in dogs. 3.
    Hallberg D; Soda M
    Acta Chir Scand; 1974; 140(5):388-90. PubMed ID: 4277503
    [No Abstract]   [Full Text] [Related]  

  • 10. Development of catalytic platinum-binder electrodes for glucose determination.
    Lemke K; Lewandowski J; Görner M; Krzymien J; Nałecz M; Szczepanska-Sadowska E
    Biomed Biochim Acta; 1985; 44(10):1445-57. PubMed ID: 4084250
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Polyvinylferrocenium modified Pt electrode for anaerobic glucose monitoring.
    Gülce A; Gülce H
    J Biochem Biophys Methods; 2005 Jan; 62(1):81-92. PubMed ID: 15656946
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel glucose biosensor based on immobilization of glucose oxidase into multiwall carbon nanotubes-polyelectrolyte-loaded electrospun nanofibrous membrane.
    Manesh KM; Kim HT; Santhosh P; Gopalan AI; Lee KP
    Biosens Bioelectron; 2008 Jan; 23(6):771-9. PubMed ID: 17905578
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transport of D-[1-14C]-amino acids into Chinese hamster ovary (CHO-K1) cells: implications for use of labeled d-amino acids as molecular imaging agents.
    Shikano N; Nakajima S; Kotani T; Ogura M; Sagara J; Iwamura Y; Yoshimoto M; Kubota N; Ishikawa N; Kawai K
    Nucl Med Biol; 2007 Aug; 34(6):659-65. PubMed ID: 17707806
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Selective and sensitive electrochemical detection of glucose in neutral solution using platinum-lead alloy nanoparticle/carbon nanotube nanocomposites.
    Cui HF; Ye JS; Zhang WD; Li CM; Luong JH; Sheu FS
    Anal Chim Acta; 2007 Jul; 594(2):175-83. PubMed ID: 17586112
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode.
    Tang H; Chen J; Yao S; Nie L; Deng G; Kuang Y
    Anal Biochem; 2004 Aug; 331(1):89-97. PubMed ID: 15246000
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Permselective and enzyme-entrapping behaviours of an electropolymerized, non-conducting, poly(o-aminophenol) thin film-modified electrode: a critical study.
    Guerrieri A; Ciriello R; Centonze D
    Biosens Bioelectron; 2009 Feb; 24(6):1550-6. PubMed ID: 19022646
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Free lysine, glycine, alanine, glutamic acid and aspartic acid reduce the glycation of human lens proteins by galactose.
    Ramakrishnan S; Sulochana KN; Punitham R
    Indian J Biochem Biophys; 1997 Dec; 34(6):518-23. PubMed ID: 9594433
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enzyme-free amperometric sensing of glucose by using gold nanoparticles.
    Jena BK; Raj CR
    Chemistry; 2006 Mar; 12(10):2702-8. PubMed ID: 16429473
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a D-amino acids electrochemical sensor based on immobilization of thermostable D-proline dehydrogenase within agar gel membrane.
    Tani Y; Tanaka K; Yabutani T; Mishima Y; Sakuraba H; Ohshima T; Motonaka J
    Anal Chim Acta; 2008 Jul; 619(2):215-20. PubMed ID: 18558115
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pt-Pb nanowire array electrode for enzyme-free glucose detection.
    Bai Y; Sun Y; Sun C
    Biosens Bioelectron; 2008 Dec; 24(4):579-85. PubMed ID: 18619831
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.