These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 8187469)

  • 1. The dual tracer time-varying volume method for measuring hepatic glucose release in nonsteady state: theoretical and simulation results.
    Caumo A; Zerman A; Rizza R; Cobelli C
    Comput Methods Programs Biomed; 1994 Jan; 41(3-4):243-67. PubMed ID: 8187469
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Methods for assessment of the rate of onset and offset of insulin action during nonsteady state in humans.
    Butler PC; Caumo A; Zerman A; O'Brien PC; Cobelli C; Rizza RA
    Am J Physiol; 1993 Apr; 264(4 Pt 1):E548-60. PubMed ID: 8476033
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Non-steady state: error analysis of Steele's model and developments for glucose kinetics.
    Cobelli C; Mari A; Ferrannini E
    Am J Physiol; 1987 May; 252(5 Pt 1):E679-89. PubMed ID: 3578516
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hepatic and extrahepatic insulin action in humans: measurement in the absence of non-steady-state error.
    Katz H; Butler P; Homan M; Zerman A; Caumo A; Cobelli C; Rizza R
    Am J Physiol; 1993 Apr; 264(4 Pt 1):E561-6. PubMed ID: 8476034
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimation of the rate of appearance in the non-steady state with a two-compartment model.
    Mari A
    Am J Physiol; 1992 Aug; 263(2 Pt 1):E400-15. PubMed ID: 1514623
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Theory of production rate calculations in steady and non-steady states and its application to glucose metabolism.
    Jacquez JA
    Am J Physiol; 1992 Jun; 262(6 Pt 1):E779-90. PubMed ID: 1616015
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Glucose turnover in presence of changing glucose concentrations: error analysis for glucose disappearance.
    Caumo A; Homan M; Katz H; Cobelli C; Rizza R
    Am J Physiol; 1995 Sep; 269(3 Pt 1):E557-67. PubMed ID: 7573434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modeling error and apparent isotope discrimination confound estimation of endogenous glucose production during euglycemic glucose clamps.
    Finegood DT; Bergman RN; Vranic M
    Diabetes; 1988 Aug; 37(8):1025-34. PubMed ID: 3292323
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Integrated model of hepatic and peripheral glucose regulation for estimation of endogenous glucose production during the hot IVGTT.
    Krudys KM; Dodds MG; Nissen SM; Vicini P
    Am J Physiol Endocrinol Metab; 2005 May; 288(5):E1038-46. PubMed ID: 15632105
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of a variable hepatic insulin clearance on the postprandial insulin profile: insights from a model simulation study.
    Caumo A; Florea I; Luzi L
    Acta Diabetol; 2007 Mar; 44(1):23-9. PubMed ID: 17357882
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of fasting on plasma glucose and prolonged tracer measurement of hepatic glucose output in NIDDM.
    Glauber H; Wallace P; Brechtel G
    Diabetes; 1987 Oct; 36(10):1187-94. PubMed ID: 3308588
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simultaneous time-varying systemic appearance of oral and hepatic glucose in adults monitored with stable isotopes.
    Livesey G; Wilson PD; Dainty JR; Brown JC; Faulks RM; Roe MA; Newman TA; Eagles J; Mellon FA; Greenwood RH
    Am J Physiol; 1998 Oct; 275(4):E717-28. PubMed ID: 9755093
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Insulin control of glucose metabolism in man: a new kinetic analysis.
    Insel PA; Liljenquist JE; Tobin JD; Sherwin RS; Watkins P; Andres R; Berman M
    J Clin Invest; 1975 May; 55(5):1057-66. PubMed ID: 15959962
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimation of endogenous glucose production during hyperinsulinemic-euglycemic glucose clamps. Comparison of unlabeled and labeled exogenous glucose infusates.
    Finegood DT; Bergman RN; Vranic M
    Diabetes; 1987 Aug; 36(8):914-24. PubMed ID: 3297886
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Experimental validation of a glucose-insulin control model to stimulate patterns in glucose turnover.
    Fischer U; Salzsieder E; Freyse EJ; Albrecht G
    Comput Methods Programs Biomed; 1990; 32(3-4):249-58. PubMed ID: 2249424
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of insulin action on glucose uptake and production during a euglycemic-hyperinsulinemic clamp in dog: a new kinetic analysis.
    McGuinness OP; Mari A
    Metabolism; 1997 Oct; 46(10):1116-27. PubMed ID: 9322792
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental validation of measurements of glucose turnover in nonsteady state.
    Radziuk J; Norwich KH; Vranic M
    Am J Physiol; 1978 Jan; 234(1):E84-93. PubMed ID: 623255
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The accuracy of measurement required for acceptable estimation of non-steady rates of appearance and disappearance by the tracer method using a two-compartment model.
    Wootton R; Flecknell PA; John M
    Clin Phys Physiol Meas; 1983 Feb; 4(1):39-46. PubMed ID: 6831841
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hepatic insulin sensitivity in healthy and prediabetic subjects: from a dual- to a single-tracer oral minimal model.
    Visentin R; Dalla Man C; Basu R; Basu A; Rizza RA; Cobelli C
    Am J Physiol Endocrinol Metab; 2015 Jul; 309(2):E161-7. PubMed ID: 25991649
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimal segments: a method for smoothing tracer data to calculate metabolic fluxes.
    Finegood DT; Bergman RN
    Am J Physiol; 1983 May; 244(5):E472-9. PubMed ID: 6846533
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.