These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 8191574)

  • 41. An improved electronic counting method for bovine leucocytes.
    Halliday WG; Ross JG; Gibson JM
    Med Lab Sci; 1979; 36(4):353-8. PubMed ID: 522621
    [No Abstract]   [Full Text] [Related]  

  • 42. Automated counting of white blood cells in synovial fluid.
    Dieppe P; Swan A
    Rheumatology (Oxford); 2004 Sep; 43(9):1201; author reply 1201-2. PubMed ID: 15317966
    [No Abstract]   [Full Text] [Related]  

  • 43. [Assessment of the capability of the fluid model of automatic blood cell analyzer in white blood cell count and classification].
    Shen J; Chen Y; Wang GZ; Ma L; Han CW
    Zhonghua Xue Ye Xue Za Zhi; 2013 Jul; 34(7):629-31. PubMed ID: 23906462
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Quality control of leucocyte-reduced blood components: overestimation of WBC content due to nucleated red blood cells.
    Fischer JC; Moog R; Giers G
    Vox Sang; 2012 Jan; 102(1):79-81. PubMed ID: 21564108
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Counting White Blood Cells from a Blood Smear Using Fourier Ptychographic Microscopy.
    Chung J; Ou X; Kulkarni RP; Yang C
    PLoS One; 2015; 10(7):e0133489. PubMed ID: 26186353
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Resistance to lysis of erythrocytes containing haemoglobin C--detected in a differential white cell counting system.
    Booth F; Mead SV
    J Clin Pathol; 1983 Jul; 36(7):816-8. PubMed ID: 6863574
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Optimal conditions for white cell reduction in red cells by filtration at the patient's bedside.
    Sirchia G; Rebulla P; Sabbioneda L; Garcea F; Greppi N
    Transfusion; 1996 Apr; 36(4):322-7. PubMed ID: 8623132
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Reducing costs in flow-cytometric counting of residual white blood cells in blood products: utilization of a single-platform bead-free flow-rate calibration method.
    Fischer JC; Quenzel EM; Moog R; Wenzel F; Riethmacher R; Tutschek B; Giers G
    Transfusion; 2011 Jul; 51(7):1431-8. PubMed ID: 21214578
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Evaluation of droplet digital PCR for quantification of residual leucocytes in red blood cell concentrates.
    Doescher A; Loges U; Petershofen EK; Müller TH
    Vox Sang; 2017 Nov; 112(8):744-750. PubMed ID: 28967676
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Efficiency of leukocyte removal by filters made of superfine glass fiber membranes.
    Zou Y; Sun Q; Li A; Yao F; Hu Z; Li Z L; Ma W
    Vox Sang; 1999; 76(1):22-6. PubMed ID: 9933850
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Cell adherence as a serious source of error in the haemacytometer count of leucocytes in artificial suspensions.
    Sällström JF
    Scand J Haematol; 1975 Jun; 14(5):328-36. PubMed ID: 1215829
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Automatic volumetric capillary cytometry for counting white cells in white cell-reduced plateletpheresis components.
    Adams MR; Johnson DK; Busch MP; Schembri CT; Hartz TP; Heaton WA
    Transfusion; 1997 Jan; 37(1):29-37. PubMed ID: 9024487
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A rare-event analysis model for quantifying white cells in white cell-depleted blood.
    Wenz B; Burns ER; Lee V; Miller WK
    Transfusion; 1991 Feb; 31(2):156-9. PubMed ID: 1996483
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Pre-mobilization therapy blood CD34+ cell count predicts the likelihood of successful hematopoietic stem cell mobilization.
    Fu P; Bagai RK; Meyerson H; Kane D; Fox RM; Creger RJ; Cooper BW; Gerson SL; Laughlin MJ; Koc ON; Lazarus HM
    Bone Marrow Transplant; 2006 Aug; 38(3):189-96. PubMed ID: 16850032
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [A problems in diagnosis of "leucocyturia". A simple method for a quantitative evaluation of urinary cell concentration (author's transl)].
    Brühl P; Mikolai D; Vahlensieck W
    Urologe A; 1979 Sep; 18(5):278-83. PubMed ID: 494453
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids.
    de Jonge R; Brouwer R; de Graaf MT; Luitwieler RL; Fleming C; de Frankrijker-Merkestijn M; Sillevis Smitt PA; Boonstra JG; Lindemans J
    Clin Chem Lab Med; 2010 May; 48(5):665-75. PubMed ID: 20187854
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Characteristics of white cell-reduced red cells stored in tri-(2-ethylhexyl)trimellitate plastic.
    Davey RJ; Heaton WA; Sweat LT; Stec NM; Nelson EJ; Holme S
    Transfusion; 1994 Oct; 34(10):895-8. PubMed ID: 7940663
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A new method to improve the discrimination between lymphocytes and contaminating erythrocytes in flow cytometric analytical techniques.
    Parker DJ; Haslam PL
    J Immunol Methods; 1988 May; 110(1):37-45. PubMed ID: 2453584
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Differential leukocyte counting and immunophenotyping in cryopreserved ex vivo whole blood.
    Nemes E; Kagina BM; Smit E; Africa H; Steyn M; Hanekom WA; Scriba TJ
    Cytometry A; 2015 Feb; 87(2):157-65. PubMed ID: 25515205
    [TBL] [Abstract][Full Text] [Related]  

  • 60. When is a white cell count not a white cell count?
    Whiting P; Bryden D
    Anaesthesia; 2002 Jul; 57(7):714. PubMed ID: 12109420
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.