21. Limitations and late complications of third-generation automatic cardioverter-defibrillators. Nunain SO; Roelke M; Trouton T; Osswald S; Kim YH; Sosa-Suarez G; Brooks DR; McGovern B; Guy M; Torchiana DF Circulation; 1995 Apr; 91(8):2204-13. PubMed ID: 7697850 [TBL] [Abstract][Full Text] [Related]
22. Marked attenuation of shock burden by the use of antitachycardia pacing therapy in a patient with an implanted cardioverter-defibrillator. Ganjehei L; Nazeri A; Massumi A; Razavi M Tex Heart Inst J; 2012; 39(4):568-70. PubMed ID: 22949781 [TBL] [Abstract][Full Text] [Related]
23. Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator. Results of a European multicenter study of 102 implants. Fromer M; Brachmann J; Block M; Siebels J; Hoffmann E; Almendral J; Ohm OJ; den Dulk K; Coumel P; Camm AJ Circulation; 1992 Aug; 86(2):363-74. PubMed ID: 1638705 [TBL] [Abstract][Full Text] [Related]
24. Paced beats following single nonsensed complexes in a "codependent" cardioverter defibrillator and bradycardia pacing system: potential for ventricular tachycardia induction. Callans DJ; Hook BG; Marchlinski FE Pacing Clin Electrophysiol; 1991 Aug; 14(8):1281-7. PubMed ID: 1719506 [TBL] [Abstract][Full Text] [Related]
26. Subcutaneous Implantable Cardioverter Defibrillator Lead Repositioning for Preventing Inappropriate Shocks Due to Myopotential Oversensing in a Post-Fulminant Myocarditis Patient. Sasaki T; Nakamura K; Naito S Int Heart J; 2019 Mar; 60(2):466-469. PubMed ID: 30745542 [TBL] [Abstract][Full Text] [Related]
27. Inappropriate discharge of an implantable cardioverter defibrillator during atrial flutter and intermittent ventricular antibradycardia pacing. Peters W; Kowallik P; Wittenberg G; Scholl C; Meesmann M J Cardiovasc Electrophysiol; 1997 Oct; 8(10):1167-74. PubMed ID: 9363821 [TBL] [Abstract][Full Text] [Related]
28. Incidence of myopotential induction in subcutaneous implantable cardioverter-defibrillator patients: Is the oversensing issue really solved? van den Bruck JH; Sultan A; Plenge T; Seuthe K; Mödder T; Iliadis C; Stern D; Blankenheim T; Steven D; Lüker J Heart Rhythm; 2019 Oct; 16(10):1523-1530. PubMed ID: 31048064 [TBL] [Abstract][Full Text] [Related]
29. The pacer-cardioverter-defibrillator: function and clinical experience. Friedman PA; Stanton MS J Cardiovasc Electrophysiol; 1995 Jan; 6(1):48-68. PubMed ID: 7743010 [TBL] [Abstract][Full Text] [Related]
30. Decrease in amplitude of intracardiac ventricular electrogram and inappropriate therapy in patients with an implantable cardioverter defibrillator. Watanabe H; Chinushi M; Izumi D; Sato A; Okada S; Okamura K; Komura S; Hosaka Y; Furushima H; Washizuka T; Aizawa Y Int Heart J; 2006 May; 47(3):363-70. PubMed ID: 16823242 [TBL] [Abstract][Full Text] [Related]
32. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device. Francisco GM; Sharma S; Dougherty AH; Kantharia BK Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529 [TBL] [Abstract][Full Text] [Related]
33. Clinical experience with antitachycardia pacing and improved detection algorithms in a new implantable cardioverter-defibrillator. Wietholt D; Block M; Isbruch F; Böcker D; Borggrefe M; Shenasa M; Breithardt G J Am Coll Cardiol; 1993 Mar; 21(4):885-94. PubMed ID: 8185728 [TBL] [Abstract][Full Text] [Related]
34. Oversensing issues leading to device extraction: When subcutaneous implantable cardioverter-defibrillator reached a dead-end. Noel A; Ploux S; Bulliard S; Strik M; Haeberlin A; Welte N; Marchand H; Klotz N; Ritter P; Haïssaguerre M; Bordachar P Heart Rhythm; 2020 Jan; 17(1):66-74. PubMed ID: 31295585 [TBL] [Abstract][Full Text] [Related]
35. A single implantable cardioverter-defibrillator shock unmasking an electrical storm of 389 ventricular tachycardia episodes triggering device therapies. Arias MA; Valverde I; Puchol A; Castellanos E; Rodríguez-Padial L; Sánchez AM; Alvarez-Temiño M; Palomino M Am J Emerg Med; 2008 Nov; 26(9):1066.e1-3. PubMed ID: 19091283 [TBL] [Abstract][Full Text] [Related]
36. Inappropriate discharges of intravenous implantable cardioverter defibrillators owing to lead failure. Washizuka T; Chinushi M; Kazama R; Hirono T; Watanabe H; Komura S; Sugiura H; Tanabe Y; Furushima H; Fujita S; Okura Y; Aizawa Y Int Heart J; 2005 Sep; 46(5):909-13. PubMed ID: 16272782 [TBL] [Abstract][Full Text] [Related]
37. T-wave oversensing and inappropriate shocks: a case report. Srivathsan K; Scott LR; Altemose GT Europace; 2008 May; 10(5):552-5. PubMed ID: 18442965 [TBL] [Abstract][Full Text] [Related]
38. Emergencies related to implantable cardioverter-defibrillators. Pinski SL Crit Care Med; 2000 Oct; 28(10 Suppl):N174-80. PubMed ID: 11055688 [TBL] [Abstract][Full Text] [Related]
39. Multiple appropriate and spurious defibrillator shocks in a patient with right ventricular cardiomyopathy. Strohmer B; Schernthaner C; Pichler M Int J Cardiol; 2005 Jul; 102(2):363-6. PubMed ID: 15982515 [TBL] [Abstract][Full Text] [Related]
40. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Spencker S; Coban N; Koch L; Schirdewan A; Müller D Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]