These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
138 related articles for article (PubMed ID: 8197841)
1. Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperations in a prospective, randomized study of 378 patients. Aune AK; Ekeland A; Odegaard B; Grøgaard B; Alho A Acta Orthop Scand; 1994 Apr; 65(2):127-30. PubMed ID: 8197841 [TBL] [Abstract][Full Text] [Related]
2. Comparison of compression hip screw and gamma nail for treatment of peritrochanteric fractures. Bess RJ; Jolly SA J South Orthop Assoc; 1997; 6(3):173-9. PubMed ID: 9322196 [TBL] [Abstract][Full Text] [Related]
3. Subtrochanteric femoral fractures treated with the Long Gamma3® nail: A historical control case study versus Long trochanteric Gamma nail®. Georgiannos D; Lampridis V; Bisbinas I Orthop Traumatol Surg Res; 2015 Oct; 101(6):675-80. PubMed ID: 26315346 [TBL] [Abstract][Full Text] [Related]
4. Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. Utrilla AL; Reig JS; Muñoz FM; Tufanisco CB J Orthop Trauma; 2005 Apr; 19(4):229-33. PubMed ID: 15795570 [TBL] [Abstract][Full Text] [Related]
5. Causes and treatments of lag screw's cut out after intramedullary nailing osteosinthesis for trochanteric fractures. Gazzotti G; Matino G; Tsatsis C; Sacchetti G; Baudi P; Catani F Acta Biomed; 2014 Aug; 85(2):135-43. PubMed ID: 25245649 [TBL] [Abstract][Full Text] [Related]
7. More postoperative femoral fractures with the Gamma nail than the sliding screw plate in the treatment of trochanteric fractures. Osnes EK; Lofthus CM; Falch JA; Meyer HE; Stensvold I; Kristiansen IS; Nordsletten L Acta Orthop Scand; 2001 Jun; 72(3):252-6. PubMed ID: 11480600 [TBL] [Abstract][Full Text] [Related]
8. A locked hip screw-intramedullary nail (cephalomedullary nail) for the treatment of fractures of the proximal part of the femur combined with fractures of the femoral shaft. Alho A; Ekeland A; Grøgaard B; Dokke JR J Trauma; 1996 Jan; 40(1):10-6. PubMed ID: 8576969 [TBL] [Abstract][Full Text] [Related]
9. [Gamma nail osteosynthesis of per- and subtrochanteric femoral fractures. 4 years experiences and their consequences for further implant development]. Friedl W; Colombo-Benkmann M; Dockter S; Machens HG; Mieck U Chirurg; 1994 Nov; 65(11):953-63. PubMed ID: 7821076 [TBL] [Abstract][Full Text] [Related]
10. A randomized study of the compression hip screw and Gamma nail in 426 fractures. Ahrengart L; Törnkvist H; Fornander P; Thorngren KG; Pasanen L; Wahlström P; Honkonen S; Lindgren U Clin Orthop Relat Res; 2002 Aug; (401):209-22. PubMed ID: 12151898 [TBL] [Abstract][Full Text] [Related]
11. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate. Paulsson J; Stig JC; Olsson O BMC Musculoskelet Disord; 2017 Aug; 18(1):364. PubMed ID: 28836973 [TBL] [Abstract][Full Text] [Related]
12. Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. Hardy DC; Descamps PY; Krallis P; Fabeck L; Smets P; Bertens CL; Delince PE J Bone Joint Surg Am; 1998 May; 80(5):618-30. PubMed ID: 9611022 [TBL] [Abstract][Full Text] [Related]
13. Complications following the treatment of trochanteric fractures with the gamma nail. Hesse B; Gächter A Arch Orthop Trauma Surg; 2004 Dec; 124(10):692-8. PubMed ID: 15517321 [TBL] [Abstract][Full Text] [Related]
14. Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures. Sahin S; Ertürer E; Oztürk I; Toker S; Seçkin F; Akman S Acta Orthop Traumatol Turc; 2010; 44(2):127-34. PubMed ID: 20676015 [TBL] [Abstract][Full Text] [Related]
15. Is the proximal femoral nail a suitable implant for treatment of all trochanteric fractures? Menezes DF; Gamulin A; Noesberger B Clin Orthop Relat Res; 2005 Oct; 439():221-7. PubMed ID: 16205163 [TBL] [Abstract][Full Text] [Related]
16. The Holland nail: a universal implant for fractures of the proximal femur and the femoral shaft. Krastman P; Welvaart WN; Breugem SJ; van Vugt AB Injury; 2004 Feb; 35(2):170-8. PubMed ID: 14736476 [TBL] [Abstract][Full Text] [Related]
17. A prospective randomised comparison of the dynamic hip screw and the gamma locking nail. Radford PJ; Needoff M; Webb JK J Bone Joint Surg Br; 1993 Sep; 75(5):789-93. PubMed ID: 8376441 [TBL] [Abstract][Full Text] [Related]
18. Does an additional antirotation U-Blade (RC) lag screw improve treatment of AO/OTA 31 A1-3 fractures with gamma 3 nail? Lang NW; Arthold C; Joestl J; Gormasz A; Boesmueller S; Hajdu S; Sarahrudi K Injury; 2016 Dec; 47(12):2733-2738. PubMed ID: 27832831 [TBL] [Abstract][Full Text] [Related]
19. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: a review of 93 cases. Crawford CH; Malkani AL; Cordray S; Roberts CS; Sligar W J Trauma; 2006 Feb; 60(2):325-8; discussion 328-9. PubMed ID: 16508490 [TBL] [Abstract][Full Text] [Related]
20. Treatment of subtrochanteric fractures. A comparison of the Gamma nail and the dynamic hip screw: short-term outcome in 58 patients. Saarenpää I; Heikkinen T; Jalovaara P Int Orthop; 2007 Feb; 31(1):65-70. PubMed ID: 16633810 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]