These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 8200113)

  • 1. Variable selectivity of the Hitachi chemistry analyzer chloride ion-selective electrode toward interfering ions.
    Wang T; Diamandis EP; Lane A; Baines AD
    Clin Biochem; 1994 Feb; 27(1):37-14. PubMed ID: 8200113
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Anion recognition using newly synthesized hydrogen bonding disubstituted phenylhydrazone-based receptors: poly(vinyl chloride)-based sensor for acetate.
    Gupta VK; Goyal RN; Sharma RA
    Talanta; 2008 Aug; 76(4):859-64. PubMed ID: 18656670
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early detection of the selectivity loss of the Cobas Integra analyzer chloride ion-selective electrode.
    Braun SL; Ciolek K; Vogt W
    Clin Chem; 2004 Jul; 50(7):1272-3. PubMed ID: 15229168
    [No Abstract]   [Full Text] [Related]  

  • 4. Impact of Bicarbonate Interference on Routine Ion-Selective Electrode Chloride Measurements.
    Monteyne T; Oyaert M; Van Dalem A; Godefroid M; Cuykx M; Callewaert N
    Ann Lab Med; 2022 Sep; 42(5):566-574. PubMed ID: 35470274
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Selective determination of chloride and bromide ions in serum by cyclic voltammetry.
    Arai K; Kusu F; Noguchi N; Takamura K; Osawa H
    Anal Biochem; 1996 Aug; 240(1):109-13. PubMed ID: 8811885
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temperature dependence of chloride, bromide, iodide, thiocyanate and salicylate transport in human red cells.
    Dalmark M; Wieth JO
    J Physiol; 1972 Aug; 224(3):583-610. PubMed ID: 5071931
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Technicon RA-1000 evaluated for measuring sodium, potassium, chloride, and carbon dioxide.
    Ng RH; Altaffer M; Ito R; Statland BE
    Clin Chem; 1985 Mar; 31(3):435-8. PubMed ID: 3918809
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the Hitachi 911 for routine urine analysis and for measurement of various special serum analytes.
    van Straalen JP; Leyte A; Weber JA; Gorgels JP; Sanders GT
    Eur J Clin Chem Clin Biochem; 1995 May; 33(5):315-22. PubMed ID: 7578611
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The determination of chloride in plasma and serum (mercury(II)-thiocyanate method) with the Greiner Electronic Selective Analyzer GSA II (author's transl)].
    Küffer H; Richterich R; Kraft R; Peheim E; Colombo JP
    Z Klin Chem Klin Biochem; 1975 May; 13(5):203-11. PubMed ID: 1210504
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hydrogen ion-selective poly(vinyl chloride) membrane electrode based on a calix[4]arene.
    Kuruoğlu D; Canel E; Memon S; Yilmaz M; Kiliç E
    Anal Sci; 2003 Feb; 19(2):217-21. PubMed ID: 12608748
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of bromide and iodide on chloride methodologies in plasma or serum.
    Baker C; Kahn SE; Bermes EW
    Ann Clin Lab Sci; 1980; 10(6):523-8. PubMed ID: 7447395
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Chloride-selective electrode based on molecular oriented membrane.
    Terauchi Y; Yanagi H; Watanabe S
    Scand J Clin Lab Invest Suppl; 1996; 224():161-4. PubMed ID: 8865431
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thiocyanate ion-selective PVC membrane electrode based on N,N'-ethylene-bis(4-methylsalicylidineiminato)nickel(II).
    Mazloum Ardakani M; Jamshidpour M; Naeimi H; Moradi L
    Anal Sci; 2006 Sep; 22(9):1221-6. PubMed ID: 16966813
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A selective optical chemosensor based on a thia-containing Schiff-base iron(III) complex for thiocyanate ion.
    Ershad S; Sagathforoush LA; Karim-Nezhad G
    Anal Sci; 2009 May; 25(5):665-8. PubMed ID: 19430150
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 8-hydroxyquinoline based neutral tripodal ionophore as a copper (II) selective electrode and the effect of remote substitutents on electrode properties.
    Mittal SK; Kumar A; Gupta N; Kaur S; Kumar S
    Anal Chim Acta; 2007 Feb; 585(1):161-70. PubMed ID: 17386661
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Serum chloride analysis, bromide detection, and the diagnosis of bromism.
    Wenk RE; Lustagarten JA; Pappas NJ; Levy RI; Jackson R
    Am J Clin Pathol; 1976 Jan; 65(1):49-57. PubMed ID: 1246988
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Synthesis and characterization of bis nitrato[4-hydroxyacetophenonesemicarbazone) nickel(II) complex as ionophore for thiocyanate-selective electrode.
    Chandra S; Hooda S; Tomar PK; Malik A; Kumar A; Malik S; Gautam S
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():18-27. PubMed ID: 26952393
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Highly selective thiocyanate membrane electrode based on butane-2,3-dione bis(salicylhydrazonato)zinc(II) complex.
    Ardakani MM; Sadeghi A; Salavati-Niasari M
    Talanta; 2005 May; 66(4):837-43. PubMed ID: 18970061
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of ion-carrier substituents on the potentiometric-response characteristics in anion-selective membrane electrodes based on iron porphyrins.
    Shahrokhian S; Seifi H; Bagherzadeh M; Mousavi SR
    Chemphyschem; 2004 May; 5(5):652-60. PubMed ID: 15179717
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nonselectivity of the chloride ion-selective electrode used in the Hitachi 705.
    Slater S; Wyndham L
    Clin Chem; 1986 Feb; 32(2):405-6. PubMed ID: 3943219
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.