BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 8200388)

  • 1. Dual-isotope myocardial imaging: feasibility, advantages and limitations. Preliminary report on 231 consecutive patients.
    Weinmann P; Foult JM; Le Guludec D; Tamgac F; Rechtman D; Neuman A; Caillat-Vigneron N; Moretti JL
    Eur J Nucl Med; 1994 Mar; 21(3):212-5. PubMed ID: 8200388
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT.
    Kiat H; Germano G; Friedman J; Van Train K; Silagan G; Wang FP; Maddahi J; Berman D
    J Nucl Med; 1994 Apr; 35(4):542-8. PubMed ID: 8151372
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of rest thallium-201 imaging and rest technetium-99m sestamibi imaging for assessment of myocardial viability in patients with coronary artery disease and severe left ventricular dysfunction.
    Kauffman GJ; Boyne TS; Watson DD; Smith WH; Beller GA
    J Am Coll Cardiol; 1996 Jun; 27(7):1592-7. PubMed ID: 8636541
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study.
    Berman DS; Kiat H; Friedman JD; Wang FP; van Train K; Matzer L; Maddahi J; Germano G
    J Am Coll Cardiol; 1993 Nov; 22(5):1455-64. PubMed ID: 8227805
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defects.
    Siebelink HM; Natale D; Sinusas AJ; Wackers FJ
    J Nucl Cardiol; 1996; 3(6 Pt 1):483-93. PubMed ID: 8989673
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of thallium-201 resting redistribution with technetium-99m-sestamibi uptake and functional response to dobutamine for assessment of myocardial viability.
    Sansoy V; Glover DK; Watson DD; Ruiz M; Smith WH; Simanis JP; Beller GA
    Circulation; 1995 Aug; 92(4):994-1004. PubMed ID: 7641384
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Gated technetium-99m sestamibi for simultaneous assessment of stress myocardial perfusion, postexercise regional ventricular function and myocardial viability. Correlation with echocardiography and rest thallium-201 scintigraphy.
    Chua T; Kiat H; Germano G; Maurer G; van Train K; Friedman J; Berman D
    J Am Coll Cardiol; 1994 Apr; 23(5):1107-14. PubMed ID: 8144776
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility of simultaneous stress 99mTc-sestamibi/rest 201Tl dual-isotope myocardial perfusion SPECT in the detection of coronary artery disease.
    Nakamura M; Takeda K; Ichihara T; Motomura N; Shimizu H; Saito Y; Nomura Y; Isaka N; Konishi T; Nakano T
    J Nucl Med; 1999 Jun; 40(6):895-903. PubMed ID: 10452303
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predicting recovery of severe regional ventricular dysfunction. Comparison of resting scintigraphy with 201Tl and 99mTc-sestamibi.
    Udelson JE; Coleman PS; Metherall J; Pandian NG; Gomez AR; Griffith JL; Shea NL; Oates E; Konstam MA
    Circulation; 1994 Jun; 89(6):2552-61. PubMed ID: 8205664
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.
    Okudan B; Smitherman TC
    Anadolu Kardiyol Derg; 2004 Jun; 4(2):161-8. PubMed ID: 15165953
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dual-isotope SPET 201Tl rest/99mTc-MIBI stress: one-day protocol for pre-operative myocardial imaging?
    Fikrle A; Rösler H; Ritter EP; Lüscher D; Ledermann H; Berthold T
    Nuklearmedizin; 1994 Apr; 33(2):135-40. PubMed ID: 8177757
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preoperative cardiac risk assessment with adenosine stress dual-isotope myocardial single-photon emission computed tomography.
    Maunoury C; Stone DA; Chen CC; Plotnick GD; Holder LE
    Clin Cardiol; 1996 Jun; 19(6):488-90. PubMed ID: 8790954
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of myocardial perfusion and viability with technetium-99m methoxyisobutylisonitrile and thallium-201 rest redistribution in chronic coronary artery disease.
    Rossetti C; Landoni C; Lucignani G; Huang G; Bartorelli AL; Guazzi MD; Margonato A; Chierchia S; Galli L; Savi A
    Eur J Nucl Med; 1995 Nov; 22(11):1306-12. PubMed ID: 8575482
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantification of left ventricular function with thallium-201 and technetium-99m-sestamibi myocardial gated SPECT.
    Maunoury C; Chen CC; Chua KB; Thompson CJ
    J Nucl Med; 1997 Jun; 38(6):958-61. PubMed ID: 9189150
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of patient height and weight and type of stress on myocardial count density during SPECT imaging with thallium-201 and technetium 99m-sestamibi.
    O'Connor MK; Bothun E; Gibbons RJ
    J Nucl Cardiol; 1998; 5(3):304-12. PubMed ID: 9669585
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Myocardial viability in patients with chronic coronary artery disease. Comparison of 99mTc-sestamibi with thallium reinjection and [18F]fluorodeoxyglucose.
    Dilsizian V; Arrighi JA; Diodati JG; Quyyumi AA; Alavi K; Bacharach SL; Marin-Neto JA; Katsiyiannis PT; Bonow RO
    Circulation; 1994 Feb; 89(2):578-87. PubMed ID: 8313546
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of electrocardiographic-gated technetium-99m sestamibi single-photon emission computed tomographic imaging and rest-redistribution thallium-201 in the prediction of myocardial viability.
    Duncan BH; Ahlberg AW; Levine MG; McGill CC; Mann A; White MP; Mather JF; Waters DD; Heller GV
    Am J Cardiol; 2000 Mar; 85(6):680-4. PubMed ID: 12000040
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pharmacologic stress dual-isotope myocardial perfusion single-photon emission computed tomography.
    Matzer L; Kiat H; Wang FP; Van Train K; Germano G; Friedman J; Berman DS
    Am Heart J; 1994 Dec; 128(6 Pt 1):1067-76. PubMed ID: 7985586
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of baseline-nitrate technetium-99m sestamibi with rest-redistribution thallium-201 tomography in detecting viable hibernating myocardium and predicting postrevascularization recovery.
    Sciagrà R; Bisi G; Santoro GM; Zerauschek F; Sestini S; Pedenovi P; Pappagallo R; Fazzini PF
    J Am Coll Cardiol; 1997 Aug; 30(2):384-91. PubMed ID: 9247509
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of resting images from two myocardial perfusion tracers.
    Anagnostopoulos C; Laney R; Pennell D; Proukakis H; Underwood R
    Eur J Nucl Med; 1995 Sep; 22(9):1029-34. PubMed ID: 7588940
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.