These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

294 related articles for article (PubMed ID: 8207572)

  • 21. Cyclic loading of olecranon fracture fixation constructs.
    Hutchinson DT; Horwitz DS; Ha G; Thomas CW; Bachus KN
    J Bone Joint Surg Am; 2003 May; 85(5):831-7. PubMed ID: 12728033
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
    Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
    Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical Analysis of the Kirschner-Wire Depth of the Modified Tension Band Wiring Technique in Transverse Patellar Fractures: An Experimental Study Using the Finite-Element Method.
    Kim Y; Kwon M; Ryu JY; Moon SW
    Clin Orthop Surg; 2021 Sep; 13(3):315-319. PubMed ID: 34484623
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires.
    Hoshino CM; Tran W; Tiberi JV; Black MH; Li BH; Gold SM; Navarro RA
    J Bone Joint Surg Am; 2013 Apr; 95(7):653-9. PubMed ID: 23553301
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Horizontal versus vertical orientation of the loop for tension band wiring of transverse patella fractures.
    Lee SK; Hwang YS; Choy WS
    Orthopedics; 2014 Mar; 37(3):e265-71. PubMed ID: 24762154
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Is There Any Difference Between The Biomechanical Strengths Of The Current Fixation Techniques For Comminuted Distal Patellar Fractures? (Comparison Of Distal Patella Fracture Fixation Techniques).
    Kocadal O; Pepe M; Gunes Z; Aksahin E; Duran S; Aktekin CN
    Acta Orthop Belg; 2017 Dec; 83(4):550-557. PubMed ID: 30423661
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Open reduction internal fixation of displaced transverse patella fractures with figure-eight wiring through parallel cannulated compression screws.
    Berg EE
    J Orthop Trauma; 1997 Nov; 11(8):573-6. PubMed ID: 9415863
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical Analysis of a Novel Buried Fixation Technique Using Headless Compression Screws for the Treatment of Patella Fractures.
    Alayan A; Maldonado R; Polakof L; Saini A; Metzger M; Lin C; Moon C
    Am J Orthop (Belle Mead NJ); 2018 Jul; 47(7):. PubMed ID: 30075035
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cannulated Screw Prominence in Tension Band Wiring of Patella Fractures Increases Fracture Gapping: A Cadaver Study.
    Avery MC; Jo S; Chang A; Ricci WM; McAndrew C; Miller AN; Tang S
    Clin Orthop Relat Res; 2019 May; 477(5):1249-1255. PubMed ID: 30998643
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].
    Zhang J; Jiang XY; Huang XW
    Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Jun; 48(3):534-8. PubMed ID: 27318920
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of the Therapeutic Effects of Tension Band with Cannulated Screw and Tension Band with Kirschner Wire on Patella Fracture.
    Liu C; Ren H; Wan C; Ma J
    Comput Math Methods Med; 2020; 2020():4065978. PubMed ID: 32908578
    [TBL] [Abstract][Full Text] [Related]  

  • 32. ORIF Patella Fracture With a Tension Band Construct.
    Blum L; Hake M
    J Orthop Trauma; 2017 Aug; 31 Suppl 3():S8-S9. PubMed ID: 28697071
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical comparison of fixation methods in transverse patella fractures.
    Scilaris TA; Grantham JL; Prayson MJ; Marshall MP; Hamilton JJ; Williams JL
    J Orthop Trauma; 1998; 12(5):356-9. PubMed ID: 9671189
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System.
    Yang X; Wu Q; Lai CH; Wang X
    Injury; 2017 Oct; 48(10):2348-2353. PubMed ID: 28733044
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.
    Li J; Wang D; He Z; Shi H
    J Invest Surg; 2019 Sep; 32(6):566-570. PubMed ID: 29308925
    [No Abstract]   [Full Text] [Related]  

  • 36. Biomechanical Evaluation of Transverse Patella Fracture Fixation Using Headless Screws: A Comparison of Suture Versus Cable as a Tension Band.
    Bric JD; Martin JM; McGrady LM; Wang M; Schmeling GJ
    J Orthop Trauma; 2023 Jun; 37(6):e253-e257. PubMed ID: 36729011
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reconstruction of patella fractures with the tension band technique: A review on clinical results and tips and tricks.
    Bel JC; Lefèvre C
    Injury; 2024 Jun; 55 Suppl 1():111401. PubMed ID: 39069346
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Fixation of multifragmentary patella fractures using a bilateral fixed-angle plate.
    Thelen S; Betsch M; Schneppendahl J; Grassmann J; Hakimi M; Eichler C; Windolf J; Wild M
    Orthopedics; 2013 Nov; 36(11):e1437-43. PubMed ID: 24200450
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The biomechanical evaluation of polyester as a tension band for the internal fixation of patellar fractures.
    McGreal G; Reidy D; Joy A; Mahalingam K; Cashman WF
    J Med Eng Technol; 1999; 23(2):53-6. PubMed ID: 10356674
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Functional outcomes after operatively treated patella fractures.
    LeBrun CT; Langford JR; Sagi HC
    J Orthop Trauma; 2012 Jul; 26(7):422-6. PubMed ID: 22183197
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.