These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
63 related articles for article (PubMed ID: 8208092)
1. [Medical gels for ultrasonographic diagnosis, therapy and electrocardiography]. Vengerova NA; Rudman AR; Burdygina IF; Kopylova EM; Efremova LN; Pashinina OB; Demina OL; Kolganova IV; Belichenko AS; Raĭgorodskiĭ IM Med Tekh; 1994; (1):44-5. PubMed ID: 8208092 [TBL] [Abstract][Full Text] [Related]
2. [Evaluation of usefulness for a new composition of gel for ultrasonographic diagnostic examination]. Kecik T; Lewandowski P; Portacha L; Waszczuk T; Marchlewska B; Pacak I Klin Oczna; 1993 Jul; 95(7):258-60. PubMed ID: 8121142 [TBL] [Abstract][Full Text] [Related]
3. A clinical trial of the effectiveness of water as a conductive medium in electrocardiography. Birks M; Santamaria N; Thompson S; Amerena J Aust J Adv Nurs; 1992 Dec-1993 Feb; 10(2):10-3. PubMed ID: 1341197 [TBL] [Abstract][Full Text] [Related]
4. Conformal thermal therapy using planar ultrasound transducers and adaptive closed-loop MR temperature control: demonstration in gel phantoms and ex vivo tissues. Tang K; Choy V; Chopra R; Bronskill MJ Phys Med Biol; 2007 May; 52(10):2905-19. PubMed ID: 17473359 [TBL] [Abstract][Full Text] [Related]
5. Feasibility of using ultrasound contrast agents to increase the size of thermal lesions induced by non-focused transducers: in vitro demonstration in tissue mimicking phantom. Lafon C; Murillo-Rincon A; Goldenstedt C; Chapelon JY; Mithieux F; Owen NR; Cathignol D Ultrasonics; 2009 Feb; 49(2):172-8. PubMed ID: 18796342 [TBL] [Abstract][Full Text] [Related]
6. [Comparative study of ultrasound transducers in HIFU]. Huo YM; Chen YZ Zhongguo Yi Liao Qi Xie Za Zhi; 2000 Feb; 24(2):97-101. PubMed ID: 12583098 [TBL] [Abstract][Full Text] [Related]
7. Fluorescence imaging for real-time monitoring of high-intensity focused ultrasound cardiac ablation. Deng CX; Qu F; Nikolski VP; Zhou Y; Efimov IR Ann Biomed Eng; 2005 Oct; 33(10):1352-9. PubMed ID: 16240084 [TBL] [Abstract][Full Text] [Related]
8. [The influence of ultrasound therapy on patient's blood pressure subjected to activity ultrasound]. Ciejka E; Wiechna K Pol Merkur Lekarski; 2009 Jul; 27(157):26-9. PubMed ID: 19650425 [TBL] [Abstract][Full Text] [Related]
9. The Cox-Maze III procedure success rate: comparison by electrocardiogram, 24-hour holter monitoring and long-term monitoring. Ad N; Henry L; Hunt S; Barnett S; Stone L Ann Thorac Surg; 2009 Jul; 88(1):101-5. PubMed ID: 19559203 [TBL] [Abstract][Full Text] [Related]
10. Transmissivity of coupling agents used to deliver ultrasound through indirect methods. Klucinec B; Scheidler M; Denegar C; Domholdt E; Burgess S J Orthop Sports Phys Ther; 2000 May; 30(5):263-9. PubMed ID: 10817413 [No Abstract] [Full Text] [Related]
11. Medical and non-medical protection standards for ultrasound and infrasound. Duck FA Prog Biophys Mol Biol; 2007; 93(1-3):176-91. PubMed ID: 16965806 [TBL] [Abstract][Full Text] [Related]
12. Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators. Chopra R; Burtnyk M; Haider MA; Bronskill MJ Phys Med Biol; 2005 Nov; 50(21):4957-75. PubMed ID: 16237234 [TBL] [Abstract][Full Text] [Related]
13. Ultrasound-induced angiogenic response in endothelial cells. Mizrahi N; Seliktar D; Kimmel E Ultrasound Med Biol; 2007 Nov; 33(11):1818-29. PubMed ID: 17681676 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of the dosimetric performance of BANG3 polymer gel. MacDougall ND; Miquel ME; Wilson DJ; Keevil SF; Smith MA Phys Med Biol; 2005 Apr; 50(8):1717-26. PubMed ID: 15815092 [TBL] [Abstract][Full Text] [Related]
15. Harmonic motion imaging for focused ultrasound (HMIFU): a fully integrated technique for sonication and monitoring of thermal ablation in tissues. Maleke C; Konofagou EE Phys Med Biol; 2008 Mar; 53(6):1773-93. PubMed ID: 18367802 [TBL] [Abstract][Full Text] [Related]
16. Simulation of sound field in a tissue medium generated by a concave spherically annular transducer. Qian S; Kamakura T; Akiyama M Ultrasonics; 2006 Dec; 44 Suppl 1():e271-4. PubMed ID: 16843509 [TBL] [Abstract][Full Text] [Related]
17. [Foetal electrocardiography (ECG) is an alternative to Doppler ultrasound cardiotocogram (CTG) for antenatal assessment of foetal well-being--preliminary results]. Reinhard J; Hatzmann H; Schiermeier S Z Geburtshilfe Neonatol; 2008 Dec; 212(6):226-9. PubMed ID: 19085740 [TBL] [Abstract][Full Text] [Related]
18. A soft-computing methodology for noninvasive time-spatial temperature estimation. Teixeira CA; Ruano MG; Ruano AE; Pereira WC IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):572-80. PubMed ID: 18269992 [TBL] [Abstract][Full Text] [Related]
19. A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers. Bazán I; Vazquez M; Ramos A; Vera A; Leija L Ultrasonics; 2009 Mar; 49(3):358-76. PubMed ID: 19100591 [TBL] [Abstract][Full Text] [Related]
20. A comparison of sonographic image quality between the examinations using gel and olive oil, as sound media. Luewan S; Srisupundit K; Tongsong T J Med Assoc Thai; 2007 Apr; 90(4):624-7. PubMed ID: 17487114 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]