These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 8208210)

  • 21. Evaluation of optimized compensators on a 3D planning system.
    Basran PS; Ansbacher W; Field GC; Murray BR
    Med Phys; 1998 Oct; 25(10):1837-44. PubMed ID: 9800689
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effectiveness of compensating filters in the presence of tissue inhomogeneities.
    Sethi A; Leybovich L; Dogan N; Glasgow G
    J Appl Clin Med Phys; 2003; 4(3):209-16. PubMed ID: 12841791
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy.
    Schembri V; Heijmen BJ
    Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Re-planning for compensator-based IMRT with original compensators.
    Zhang G; Feygelman V; Stevens C; Li W; Leuthold S; Springett G; Hoffe S
    Med Dosim; 2011; 36(1):102-8. PubMed ID: 20207532
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Radiological properties of a wax-gypsum compensator material.
    du Plessis FC; Willemse CA
    Med Phys; 2005 May; 32(5):1246-55. PubMed ID: 15984675
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Investigation of the relative surface dose from Lipowitz-metal tissue compensators for 24- and 6-MV photon beams.
    Cardarelli GA; Rao SN; Cail D
    Med Phys; 1991; 18(2):282-7. PubMed ID: 1904529
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A glass compensator filter to improve breast image quality in radiation therapy simulation.
    Ju SG; Huh SJ; Lee KC; Yeo IJ; Ahn YC; Kim DY; Kim JS; Kim MK; Lim DH; Park YH
    Int J Radiat Oncol Biol Phys; 2000 Mar; 46(4):1061-4. PubMed ID: 10705030
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Initial implementation of the conversion from the energy-subtracted CT number to electron density in tissue inhomogeneity corrections: an anthropomorphic phantom study of radiotherapy treatment planning.
    Tsukihara M; Noto Y; Sasamoto R; Hayakawa T; Saito M
    Med Phys; 2015 Mar; 42(3):1378-88. PubMed ID: 25735292
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical considerations in the use of missing tissue compensators for thoracic cases.
    Sharma SC; Johnson MW
    Med Dosim; 1997; 22(2):107-12. PubMed ID: 9243463
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Use of a multileaf collimator as a dynamic missing-tissue compensator.
    Geis P; Boyer AL; Wells NH
    Med Phys; 1996 Jul; 23(7):1199-205. PubMed ID: 8839413
    [TBL] [Abstract][Full Text] [Related]  

  • 31. An analytic approach to optimized retracted missing tissue compensators.
    Robinson DM; Scrimger JW
    Med Dosim; 1990 Jun; 15(2):51-9. PubMed ID: 2118359
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Validation of OSLD and a treatment planning system for surface dose determination in IMRT treatments.
    Zhuang AH; Olch AJ
    Med Phys; 2014 Aug; 41(8):081720. PubMed ID: 25086530
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical considerations in the use of missing tissue compensators for head and neck cases.
    Sharma SC; Johnson MW
    Med Dosim; 1998; 23(4):267-70. PubMed ID: 9863724
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The adaptation of megavoltage cone beam CT for use in standard radiotherapy treatment planning.
    Thomas TH; Devakumar D; Purnima S; Ravindran BP
    Phys Med Biol; 2009 Apr; 54(7):2067-77. PubMed ID: 19287087
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Study on surface dose generated in prostate intensity-modulated radiation therapy treatment.
    Chow JC; Grigorov GN; Barnett RB
    Med Dosim; 2006; 31(4):249-58. PubMed ID: 17134664
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Attenuation of 4-20 MV x rays by a new compensator material of cement.
    Thomsen MS; Ulsø N
    Med Phys; 2002 Oct; 29(10):2427-32. PubMed ID: 12408317
    [TBL] [Abstract][Full Text] [Related]  

  • 37. EBT GAFCHROMIC(TM) film dosimetry in compensator-based intensity modulated radiation therapy.
    Vaezzadeh S; Allahverdi M; Nedaie HA; Ay M; Shirazi A; Yarahmadi M
    Med Dosim; 2013; 38(2):176-83. PubMed ID: 23290715
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A dosimetric comparison of three compensator design methods for the mantle field.
    Cantwell JP; Renner WD; O'Connor TP; Bermudez NM
    Med Dosim; 1989 Dec; 14(4):257-63. PubMed ID: 2513827
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Tissue compensation and verification of dose uniformity.
    Park HC; Almond PR
    Med Dosim; 1993; 18(4):193-6. PubMed ID: 8311915
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The development and investigation of a prototype three-dimensional compensator for whole brain radiation therapy.
    Keall P; Arief I; Shamas S; Weiss E; Castle S
    Phys Med Biol; 2008 May; 53(9):2267-76. PubMed ID: 18401061
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.