These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 8214674)

  • 41. [Contra: cuffed endotracheal tubes in small children].
    Holzki J
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2004 Jun; 39(6):368-70. PubMed ID: 15197672
    [No Abstract]   [Full Text] [Related]  

  • 42. [Videolaryngoscopy for endotracheal intubation - new developments in difficult airway management].
    Wasem S; Roewer N; Lange M
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2009 Jul; 44(7-8):502-8. PubMed ID: 19629911
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A fire in the mouth. A hazard of the use of antistatic endotracheal tubes.
    Boyd CH
    Anaesthesia; 1969 Jul; 24(3):441-6. PubMed ID: 5791065
    [No Abstract]   [Full Text] [Related]  

  • 44. [Experiences with a non-inflammable tube in laser surgery of the larynx].
    Pramesberger G; Fischer PL; Benke A; Glaninger J
    Anaesthesist; 1985 Nov; 34(11):636-7. PubMed ID: 4091251
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Kinking of an endotracheal tube within the trachea: a rare cause of endotracheal tube obstruction.
    Leissner KB; Ortega R; Bodzin AS; Sekhar P; Stanley GD
    J Clin Anesth; 2007 Feb; 19(1):75-6. PubMed ID: 17321933
    [No Abstract]   [Full Text] [Related]  

  • 46. [Igniting the endotracheal tube in tracheotomy with electrocautery. How it should not be done].
    Albegger KW
    HNO; 1996 May; 44(5):271. PubMed ID: 8707634
    [No Abstract]   [Full Text] [Related]  

  • 47. Airway management in critically ill neurological patients.
    Dash HH
    Neurol India; 2001 Jun; 49 Suppl 1():S61-74. PubMed ID: 11889477
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Endotracheal tube narrowing after closed-system suctioning: prevalence and risk factors.
    Glass C; Grap MJ; Sessler CN
    Am J Crit Care; 1999 Mar; 8(2):93-100. PubMed ID: 10071699
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The effect of helium on endotracheal tube flammability.
    Simpson JI; Schiff GA; Wolf GL
    Anesthesiology; 1990 Sep; 73(3):538-40. PubMed ID: 2393138
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Impacted gum-elastic bougie in an endotracheal tube after successful intubation of a difficult airway.
    Arya VK; Makker S; Bedi SP
    J Clin Anesth; 2007 Nov; 19(7):566. PubMed ID: 18063220
    [No Abstract]   [Full Text] [Related]  

  • 51. Time to correct a recurring error.
    Palas TA
    Anesthesiology; 1981 Dec; 55(6):718-9. PubMed ID: 7197891
    [No Abstract]   [Full Text] [Related]  

  • 52. The dissection of a reinforced endotracheal tube causing near-fatal intraoperative airway obstruction.
    Rao GS; Ali Z; Ramkiran S; Chandrasekhar HS
    Anesth Analg; 2006 Dec; 103(6):1624-5. PubMed ID: 17122294
    [No Abstract]   [Full Text] [Related]  

  • 53. [Problems associated with the use of armored endotracheal tubes in children].
    Rubio F; Hernández A; Quintero S; Sánchez A; Cabrera J; Pantoja S
    Rev Esp Anestesiol Reanim; 1998; 45(7):305. PubMed ID: 9780771
    [No Abstract]   [Full Text] [Related]  

  • 54. Intraoperative flash fires associated with disposable cautery.
    Chestler RJ; Lemke BN
    Ophthalmic Plast Reconstr Surg; 1989; 5(3):194-5. PubMed ID: 2487222
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Endotracheal tube fire during tracheostomy: a case report.
    Awan MS; Ahmed I
    Ear Nose Throat J; 2002 Feb; 81(2):90-2. PubMed ID: 11868480
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Prevention of fire hazard during laser microsurgery.
    Kumar A; Frost E
    Anesthesiology; 1981 Apr; 54(4):350. PubMed ID: 7212341
    [No Abstract]   [Full Text] [Related]  

  • 57. Changes in resistances of endotracheal tubes with reductions in the cross-sectional area.
    El-Khatib MF; Husari A; Jamaleddine GW; Ayoub CM; Bou-Khalil P
    Eur J Anaesthesiol; 2008 Apr; 25(4):275-9. PubMed ID: 18177540
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Evaluation and management of the difficult airway].
    Rodrigo MP; García JM
    Rev Esp Anestesiol Reanim; 1996 Jan; 43(1):34-41. PubMed ID: 8851834
    [No Abstract]   [Full Text] [Related]  

  • 59. [Airway fire during electrocautery dissection of the tonsils].
    Guzmán Malpica EM; Rufino Ruiz J; Rivas Castro M; Galán Ortega M; Vidal Casas M; Cortés Sánchez R
    Rev Esp Anestesiol Reanim; 2005 Dec; 52(10):637-8. PubMed ID: 16435621
    [No Abstract]   [Full Text] [Related]  

  • 60. Conventional endotracheal tubes for intubation through the intubating laryngeal mask airway.
    Zhu T
    Anesth Analg; 2007 Jan; 104(1):213; author reply 213-4. PubMed ID: 17179279
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.