BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

228 related articles for article (PubMed ID: 8215769)

  • 21. Efficacy of lifestyle intervention on peak exercise cardiac power output and reserve in premenopausal obese females: a randomised pilot study.
    Carroll S; Marshall P; Borkoles E; Ingle L; Barker D; Tan LB
    Int J Cardiol; 2007 Jul; 119(2):147-55. PubMed ID: 17258823
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study.
    Tachibana K; Imanaka H; Takeuchi M; Nishida T; Takauchi Y; Nishimura M
    Crit Care; 2005 Oct; 9(5):R569-74. PubMed ID: 16277720
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Study of the reproducibility of cardiac output measurement during exercise in pre-pubertal children by doppler echocardiography and CO2 inhalation].
    Nottin S; Vinet A; Lecoq AM; Guenon P; Obert P
    Arch Mal Coeur Vaiss; 2000 Nov; 93(11):1297-303. PubMed ID: 11190458
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Cardiopulmonary exercise test in patients with chronic cardiac failure: comparison with normal subjects and reproducibility of measurements].
    Bugueño C; Jalil J; Godoy I; Martínez A; Chamorro G; Corbalán R; Rodríguez JA; Casanegra P; Valenzuela C; Almendarez C
    Rev Med Chil; 1995 May; 123(5):571-9. PubMed ID: 8525203
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A comparison between freon and acetylene rebreathing for measuring cardiac output.
    Bonde-Petersen F; Norsk P; Suzuki Y
    Aviat Space Environ Med; 1980 Nov; 51(11):1214-21. PubMed ID: 7213267
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Introduction and clinical evaluation of a new non-invasive cardiac output monitor (NICO) based on Fick partial CO2 rebreathing method].
    Tsujimoto S; Arimura Y; Kuroda N; Kurehara H; Tashiro C
    Masui; 2001 Jul; 50(7):799-804. PubMed ID: 11510077
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of functional residual capacity of the lung by partial CO2 rebreathing method during acute lung injury in animals.
    Brewer LM; Haryadi DG; Orr JA
    Respir Care; 2007 Nov; 52(11):1480-9. PubMed ID: 17971251
    [TBL] [Abstract][Full Text] [Related]  

  • 28. End-tidal estimates of arterial PCO2 for cardiac output measurement by CO2 rebreathing: a study in patients with cystic fibrosis and healthy controls.
    Pianosi P; Hochman J
    Pediatr Pulmonol; 1996 Sep; 22(3):154-60. PubMed ID: 8893253
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Breath-by-breath fluctuations of pulmonary gas exchange and ventilation in COPD patients.
    Puente-Maestu L; Abad MJ; Godoy R; Pérez-Parra JM; Cubillo JM; Whipp BJ
    Eur J Appl Physiol; 2002 Oct; 87(6):535-41. PubMed ID: 12355193
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Pulmonary blood flow measurement by acetylene rebreathing method in subjects without respiratory function disturbance].
    Ichinose Y; Torii Y; Yonemaru M; Utsumi K; Minemura K; Kasuga I; Toyama K; Nishi I
    Nihon Kyobu Shikkan Gakkai Zasshi; 1992 Nov; 30(11):1917-22. PubMed ID: 1484429
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Non-invasive assessment of cardiac output during mechanical ventilation - a novel approach using an inert gas rebreathing method.
    Nickl W; Bugaj T; Mondritzki T; Kuhlebrock K; Dinh W; Krahn T; Sohler F; Truebel H
    Biomed Tech (Berl); 2011 Jun; 56(3):147-51. PubMed ID: 21619467
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Can measurement of mixed venous oxygen saturation replace measurement of cardiac output in patients with advanced heart failure?
    Gawlinski A
    Am J Crit Care; 1998 Sep; 7(5):374-80; quiz 381-2. PubMed ID: 9740888
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Measurement of cardiac output after cardiac surgery: validation of a partial carbon dioxide rebreathing (NICO) system in comparison with continuous thermodilution with a pulmonary artery catheter].
    Jover JL; Soro M; Belda FJ; Aguilar G; Caro P; Ferrandis R
    Rev Esp Anestesiol Reanim; 2005 May; 52(5):256-62. PubMed ID: 15968903
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Determination of cardiac output by the CO2 - rebreathing method in fifteen-year-old boys subjected to graduated loading.
    Pärnat J; Seliger V; Trefný Z; Pauer M
    Physiol Bohemoslov; 1977; 26(1):85-93. PubMed ID: 140405
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Non-invasive measurement of cardiac output: evaluation of new infrared absorption spectrometer.
    Baum MM; Moss JA; Kumar S; Wagner PD
    Respir Physiol Neurobiol; 2006 Sep; 153(2):191-201. PubMed ID: 16326150
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Inert gas rebreathing: the effect of haemoglobin based pulmonary shunt flow correction on the accuracy of cardiac output measurements in clinical practice.
    Trinkmann F; Papavassiliu T; Kraus F; Leweling H; Schoenberg SO; Borggrefe M; Kaden JJ; Saur J
    Clin Physiol Funct Imaging; 2009 Jul; 29(4):255-62. PubMed ID: 19302227
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Non-invasive measurement of cardiac output by a carbon dioxide rebreathing method at rest and during exercise.
    Nugent AM; McParland J; McEneaney DJ; Steele I; Campbell NP; Stanford CF; Nicholls DP
    Eur Heart J; 1994 Mar; 15(3):361-8. PubMed ID: 8013510
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of continuous cardiac output measurements in patients after cardiac surgery.
    Mielck F; Buhre W; Hanekop G; Tirilomis T; Hilgers R; Sonntag H
    J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):211-6. PubMed ID: 12698404
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Assessment of cardiac output by a non-invasive method. Estimation of partial pressure of CO2 by rebreathing of expired gas. Comparison with thermodilution].
    Chabrillat Y; Jammes Y; Zwirn P; Gérard R
    Arch Mal Coeur Vaiss; 1980 Jan; 73(1):107-13. PubMed ID: 6770776
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Noninvasive monitoring of cardiac output during exercise by inductance cardiography.
    Kaplan V; Bucklar GB; Bloch KE
    Med Sci Sports Exerc; 2003 May; 35(5):747-52. PubMed ID: 12750583
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.