These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 8215952)

  • 1. Continuous hematocrit monitoring method in an extracorporeal circulation system and its application for automatic control of blood volume during artificial kidney treatment.
    Ishihara T; Igarashi I; Kitano T; Shinzato T; Maeda K
    Artif Organs; 1993 Aug; 17(8):708-16. PubMed ID: 8215952
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Newly developed circulating blood volume-monitoring system and its clinical application for measuring changes in blood volume during hemofiltration.
    Maeda K; Shinzato T; Yoshida F; Tsuruta Y; Usuda M; Yamada K; Ishihara T; Inagaki F; Igarashi I; Kitano T
    Artif Organs; 1986 Dec; 10(6):452-9. PubMed ID: 3800701
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sensitivity of Hematocrit to Osmotic Effects Induced by Changes in Dialysate Conductivity: Implications for Relative Blood Volume Measurement and Control.
    Schneditz D; Schilcher G; Ribitsch W; Zierler E; Jantscher A
    ASAIO J; 2015; 61(5):583-8. PubMed ID: 24561459
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Continuous measurement of blood volume changes in hemodialysis using an ultrasound method].
    Roob JM; Schneditz D; Haas GM; Horina JH; Pogglitsch H
    Wien Klin Wochenschr; 1990 Mar; 102(5):131-6. PubMed ID: 2181783
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Changes in blood parameters during hemodialysis as determined by conductivity measurements.
    de Vries PM; Kouw PM; Meijer JH; Oe LP; Schneider H; Donker AJ
    ASAIO Trans; 1988; 34(3):623-6. PubMed ID: 3196576
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hematocrit and blood volume control during cardiopulmonary bypass with the use of hemofiltration.
    Klineberg PL; Kam CA; Johnson DC; Cartmill TB; Brown JH
    Anesthesiology; 1984 May; 60(5):478-80. PubMed ID: 6711856
    [No Abstract]   [Full Text] [Related]  

  • 7. Merits and limitations of continuous blood volume monitoring during haemodialysis. Summary of the EDTNA/ERCA Journal Club discussion: Winter 2005.
    Lindley EJ
    EDTNA ERCA J; 2006; 32(2):108-16. PubMed ID: 16898105
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Continuous monitoring of blood volume change by measuring hematocrit during cardiopulmonary bypass].
    Horibe M; Kawanishi H; Kuroda M; Tajima M; Mochizuki T
    Masui; 1996 Feb; 45(2):189-93. PubMed ID: 8865707
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reducing symptoms during hemodialysis by continuously monitoring the hematocrit.
    Steuer RR; Leypoldt JK; Cheung AK; Senekjian HO; Conis JM
    Am J Kidney Dis; 1996 Apr; 27(4):525-32. PubMed ID: 8678063
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Variability of relative blood volume during haemodialysis.
    Krepel HP; Nette RW; Akçahüseyin E; Weimar W; Zietse R
    Nephrol Dial Transplant; 2000 May; 15(5):673-9. PubMed ID: 10809809
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of postural change on blood volume in long-term hemodialysis patients.
    Ookawara S; Suzuki M; Yahagi T; Saitou M; Tabei K
    Nephron; 2001 Jan; 87(1):27-34. PubMed ID: 11174023
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Role of hypovolemia in dialysis-induced hypotension.
    Maeda K; Morita H; Shinzato T; Vega BV; Kobayakawa H; Ishihara T; Inagaki H; Igarashi I; Kitano T
    Artif Organs; 1988 Apr; 12(2):116-21. PubMed ID: 3390008
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Non-invasive conductivity technique to detect changes in haematocrit: in vitro validation.
    Olthof CG; Kouw PM; Donker AJ; de Lange JJ; de Vries PM
    Med Biol Eng Comput; 1994 Sep; 32(5):495-500. PubMed ID: 7845065
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous arteriovenous hemofiltration in the critically ill patient. Clinical use and operational characteristics.
    Lauer A; Saccaggi A; Ronco C; Belledonne M; Glabman S; Bosch JP
    Ann Intern Med; 1983 Oct; 99(4):455-60. PubMed ID: 6625376
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New blood volume monitoring method for hemodialysis: A-V pressure gradient measurement by synchronized one-point reading.
    Oda M; Hokama S; Sugaya K; Hatano T; Ogawa Y
    Artif Organs; 2004 Jul; 28(7):683-9. PubMed ID: 15209863
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Less symptomatic hypotension using blood volume controlled ultrafiltration.
    Stiller S; Wirtz D; Waterbär F; Gladziwa U; Dakshinamurty KV; Mann H
    ASAIO Trans; 1991; 37(3):M139-41. PubMed ID: 1751083
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of dry weight by monitoring changes in blood volume during hemodialysis using Crit-Line.
    Rodriguez HJ; Domenici R; Diroll A; Goykhman I
    Kidney Int; 2005 Aug; 68(2):854-61. PubMed ID: 16014066
    [TBL] [Abstract][Full Text] [Related]  

  • 18. QRS amplitude and volume changes during hemodialysis.
    Ojanen S; Kööbi T; Korhonen P; Mustonen J; Pasternack A
    Am J Nephrol; 1999; 19(3):423-7. PubMed ID: 10393382
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Significant reduction of the large-vessel blood volume by food intake during hemodialysis.
    Shibagaki Y; Takaichi K
    Clin Nephrol; 1998 Jan; 49(1):49-54. PubMed ID: 9491287
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Haemodialysis with on-line monitoring equipment: tools or toys?
    Locatelli F; Buoncristiani U; Canaud B; Köhler H; Petitclerc T; Zucchelli P
    Nephrol Dial Transplant; 2005 Jan; 20(1):22-33. PubMed ID: 15632348
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.