These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 8223)

  • 1. Reversed-phase liquid-chromatographic analysis of hemodialysate from uremic patients.
    Senftleber FC; Halline AG; Veening H; Dayton DA
    Clin Chem; 1976 Sep; 22(9):1522-7. PubMed ID: 8223
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Liquid-chromatographic study of fluorescent materials in uremic fluids.
    Swan JS; Kragten EY; Veening H
    Clin Chem; 1983 Jun; 29(6):1082-4. PubMed ID: 6851098
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Screening of UV-absorbing solutes in uremic serum by reversed phase HPLC--change of blood levels in different therapies.
    Schoots AC; Homan HR; Gladdines MM; Cramers CA; de Smet R; Ringoir SM
    Clin Chim Acta; 1985 Feb; 146(1):37-51. PubMed ID: 3987038
    [TBL] [Abstract][Full Text] [Related]  

  • 4. HPLC study of uremic fluids related to optical dialysis adequacy monitoring.
    Lauri K; Tanner R; Jerotskaja J; Luman M; Fridolin I
    Int J Artif Organs; 2010 Feb; 33(2):96-104. PubMed ID: 20306436
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Liquid-chromatographic study of fluorescent compounds in hemodialysate solutions.
    Barnett AL; Veening H
    Clin Chem; 1985 Jan; 31(1):127-30. PubMed ID: 3917379
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Time--concentration studies by high-performance liquid chromatography of metabolites removed during hemodialysis.
    Knudson EJ; Lau YC; Veening H; Dayton DA
    Clin Chem; 1978 Apr; 24(4):686-91. PubMed ID: 639276
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Capillary electrophoresis as a clinical tool. Determination of organic anions in normal and uremic serum using photodiode-array detection.
    Petucci CJ; Kantes HL; Strein TG; Veening H
    J Chromatogr B Biomed Appl; 1995 Jun; 668(2):241-51. PubMed ID: 7581859
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Separation of albumin-binding ligands present in uremic serum by high-performance affinity chromatography.
    Mabuchi H; Nakahashi H
    J Chromatogr; 1990 Aug; 529(2):424-30. PubMed ID: 2229260
    [No Abstract]   [Full Text] [Related]  

  • 9. Separation of six uremic middle molecular compounds by high performance liquid chromatography and analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
    Chu J; Yuan Z; Liu X; Wu Q; Mi H; He B
    Clin Chim Acta; 2001 Sep; 311(2):95-107. PubMed ID: 11566169
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Identification of some abnormal metabolites in plasma from uremic subjects.
    Bultitude FW; Newham SJ
    Clin Chem; 1975 Aug; 21(9):1329-34. PubMed ID: 1149237
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Liquid chromatographic determination and time--concentration studies of riboflavin in hemodialysate from uremic patients.
    Mohammed HY; Veening H; Dayton DA
    J Chromatogr; 1981 Dec; 226(2):471-6. PubMed ID: 7320176
    [No Abstract]   [Full Text] [Related]  

  • 12. Separation of an inhibitor of erythropoiesis in "middle molecules" from hemodialysate from patients with chronic renal failure.
    Saito A; Suzuki I; Chung TG; Okamoto T; Hotta T
    Clin Chem; 1986 Oct; 32(10):1938-41. PubMed ID: 3757214
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Isolation, structure elucidation and synthesis of a hexapeptide from the hemodialysate of uremic patients].
    Bovermann G; Rautenstrauch H; Seybold G; Jung G
    Hoppe Seylers Z Physiol Chem; 1982 Oct; 363(10):1187-202. PubMed ID: 7141402
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of paracetamol and its four major metabolites in mouse plasma by reversed-phase ion-pair high-performance liquid chromatography.
    Esteban A; Graells M; Satorre J; Pérez-Mateo M
    J Chromatogr; 1992 Jan; 573(1):121-6. PubMed ID: 1564089
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Alternative high-performance liquid chromatographic peptide separation and purification concept using a new mixed-mode reversed-phase/weak anion-exchange type stationary phase.
    Nogueira R; Lämmerhofer M; Lindner W
    J Chromatogr A; 2005 Sep; 1089(1-2):158-69. PubMed ID: 16130784
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rapid assay for indoxyl sulphate in uremic serum by internal-surface reversed-phase high-performance liquid chromatography.
    Takeda N; Niwa T; Maeda K; Shibata M; Tatematsu A
    J Chromatogr; 1988 Oct; 431(2):418-23. PubMed ID: 3149642
    [No Abstract]   [Full Text] [Related]  

  • 17. High-performance liquid chromatography for ultraviolet-absorbing constituents in human urine.
    Miyagi H; Miura J; Takata Y; Ganno S
    Clin Chem; 1979 Sep; 25(9):1617-21. PubMed ID: 466788
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultraviolet-absorbing organic anions in uremic serum separated by capillary zone electrophoresis, and quantification of hippuric acid.
    Schoots AC; Verheggen TP; De Vries PM; Everaerts FM
    Clin Chem; 1990 Mar; 36(3):435-40. PubMed ID: 2311210
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-performance liquid chromatographic determination of amitriptyline and its main metabolites using a silica column with reversed-phase eluent. Application in mice.
    Coudore F; Ardid D; Eschalier A; Lavarenne J; Fialip J
    J Chromatogr; 1992 Dec; 584(2):249-55. PubMed ID: 1484109
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Uremic toxins and the elusive middle molecules.
    Schoots A; Mikkers F; Cramers C; de Smet R; Ringoir S
    Nephron; 1984; 38(1):1-8. PubMed ID: 6472528
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.