These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 8230330)

  • 1. In vitro comparison of heated saline-blood admixture with a heat exchanger for rapid warming of red blood cells.
    Cohn SM; Stack GE
    J Trauma; 1993 Nov; 35(5):688-90; discussion 690-1. PubMed ID: 8230330
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro comparison of heated saline-blood admixture with a heat exchanger for rapid warming of red blood cells.
    Iserson KV; Judkins D
    J Trauma; 1994 Mar; 36(3):461-2. PubMed ID: 8145346
    [No Abstract]   [Full Text] [Related]  

  • 3. In-line microwave blood warming of in-date human packed red blood cells.
    Pappas CG; Paddock H; Goyette P; Grabowy R; Connolly RJ; Schwaitzberg SD
    Crit Care Med; 1995 Jul; 23(7):1243-50. PubMed ID: 7600834
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Admixture bloodwarming: a technique for rapid warming of erythrocytes.
    Wilson EB; Iserson KV
    Ann Emerg Med; 1987 Apr; 16(4):413-6. PubMed ID: 3826810
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Red cell tolerance of admixture with heated saline.
    Wilson EB; Knauf MA; Iserson KV
    Transfusion; 1988; 28(2):170-2. PubMed ID: 3354046
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of fluid warmer performance during simulated clinical conditions.
    Patel N; Smith CE; Pinchak AC
    Can J Anaesth; 1995 Jul; 42(7):636-42. PubMed ID: 7554005
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid infusion of additive red blood cells: alternative techniques for massive hemorrhage.
    Floccare DJ; Kelen GD; Altman RS; Hassett JM; Qaqish B; Ness PM; Sivertson KT
    Ann Emerg Med; 1990 Feb; 19(2):129-33. PubMed ID: 2301789
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Red blood cell survival following admixture with heated saline: evaluation of a new blood warming method for rapid transfusion.
    Wilson EB; Knauf MA; Donohoe K; Iserson KV
    J Trauma; 1988 Aug; 28(8):1274-7. PubMed ID: 3411649
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Active warming of saline or blood is ineffective when standard infusion tubing is used: an experimental study.
    Bissonnette B; Paut O
    Can J Anaesth; 2002 Mar; 49(3):270-5. PubMed ID: 11861345
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of heat on stored red cells during non-flow conditions in a blood-warming device.
    Eastlund T; Van Duren A; Clay ME
    Vox Sang; 1999; 76(4):216-9. PubMed ID: 10394140
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of rapid infusion with high pressure and large-bore i.v. tubing on red blood cell lysis and warming.
    Mateer JR; Perry BW; Thompson BM; Tucker JF; Aprahamian C
    Ann Emerg Med; 1985 Oct; 14(10):966-9. PubMed ID: 4037476
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of warming and flow rate conditions of blood warmers on red blood cell integrity.
    Poder TG; Pruneau D; Dorval J; Thibault L; Fisette JF; Bédard SK; Jacques A; Beauregard P
    Vox Sang; 2016 Nov; 111(4):341-349. PubMed ID: 27280338
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Distal Limb Warming With Fluidotherapy and Warm Water Immersion for Mild Hypothermia Rewarming.
    Kumar P; McDonald GK; Chitkara R; Steinman AM; Gardiner PF; Giesbrecht GG
    Wilderness Environ Med; 2015 Sep; 26(3):406-11. PubMed ID: 26116985
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Warming resuspended erythrocyte concentrates with a new microwave device. In vitro results and clinical experiences in comparison with continuous flow warming].
    Roth-Henschker H; Holzberg E; Oppitz KH; Lehmann C
    Anaesthesist; 1988 May; 37(5):321-30. PubMed ID: 3400870
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of constant storage temperatures and multiple warming cycles on the quality of stored red blood cells.
    Wagner T; Pabst MA; Leitinger G; Reiter U; Kozma N; Lanzer G; Huppertz B
    Vox Sang; 2014 Jan; 106(1):45-54. PubMed ID: 23909508
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rapid admixture blood warming: technical advances.
    Iserson KV; Knauf MA; Anhalt D
    Crit Care Med; 1990 Oct; 18(10):1138-41. PubMed ID: 2209043
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of intravenous delivery systems on infused red blood cells.
    Gibson JS; Leff RD; Roberts RJ
    Am J Hosp Pharm; 1984 Mar; 41(3):468-72. PubMed ID: 6702849
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Steady-state and time-dependent thermodynamic modeling of the effect of intravenous infusion of warm and cold fluids.
    Barthel ER; Pierce JR
    J Trauma Acute Care Surg; 2012 Jun; 72(6):1590-600. PubMed ID: 22695427
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Increased hemolysis from saline pre-washing RBCs or centrifugal pumps in neonatal ECMO.
    Masalunga C; Cruz M; Porter B; Roseff S; Chui B; Mainali E
    J Perinatol; 2007 Jun; 27(6):380-4. PubMed ID: 17443201
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simulated clinical evaluation of conventional and newer fluid-warming devices.
    Patel N; Knapke DM; Smith CE; Napora TE; Pinchak AC; Hagen JF
    Anesth Analg; 1996 Mar; 82(3):517-24. PubMed ID: 8623954
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.