These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 8230570)

  • 1. Compliance of vascular anastomoses with polybutester and polypropylene sutures.
    Megerman J; Hamilton G; Schmitz-Rixen T; Abbott WM
    J Vasc Surg; 1993 Nov; 18(5):827-34. PubMed ID: 8230570
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of suture technique and suture material selection on the mechanics of end-to-end and end-to-side anastomoses.
    Baumgartner N; Dobrin PB; Morasch M; Dong QS; Mrkvicka R
    J Thorac Cardiovasc Surg; 1996 May; 111(5):1063-72. PubMed ID: 8622304
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Polydioxanone and polypropylene suture material in free internal mammary artery graft anastomoses.
    Aarnio P; Harjula A; Lehtola A; Sariola H; Mattila S
    J Thorac Cardiovasc Surg; 1988 Nov; 96(5):741-5. PubMed ID: 3141723
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanics of spatulated end-to-end artery-to-vein anastomoses.
    Morasch MD; Dobrin PB; Dong QS; Mrkvicka R
    Ann Vasc Surg; 1998 Jan; 12(1):55-9. PubMed ID: 9451997
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Vascular clips have no significant effect on the cellular proliferation, intimal changes, or peak systolic velocity at anastomoses in rabbit vein grafts.
    Caiati JM; Madigan JD; Bhagat G; Benvenisty AI; Nowygrod R; Todd GJ
    J Surg Res; 2000 Jul; 92(1):29-35. PubMed ID: 10864478
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of para-anastomotic compliance profiles after vascular anastomosis: nonpenetrating clips versus standard sutures.
    Baguneid MS; Goldner S; Fulford PE; Hamilton G; Walker MG; Seifalian AM
    J Vasc Surg; 2001 Apr; 33(4):812-20. PubMed ID: 11296337
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Increased compliance near vascular anastomoses.
    Hasson JE; Megerman J; Abbott WM
    J Vasc Surg; 1985 May; 2(3):419-23. PubMed ID: 3999232
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanics of end-to-end artery-to-PTFE graft anastomoses.
    Dobrin PB; Mirande R; Kang S; Dong QS; Mrkvicka R
    Ann Vasc Surg; 1998 Jul; 12(4):317-23. PubMed ID: 9676927
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The direct effect of graft compliance mismatch per se on development of host arterial intimal hyperplasia at the anastomotic interface.
    Wu MH; Shi Q; Sauvage LR; Kaplan S; Hayashida N; Patel MD; Wechezak AR; Walker MW
    Ann Vasc Surg; 1993 Mar; 7(2):156-68. PubMed ID: 8518133
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental studies with absorbable and nonabsorbable sutures in infected canine arterial anastomoses.
    Torsello GB; Sandmann W; Lenz W; Rosin H
    J Vasc Surg; 1986 Jan; 3(1):135-9. PubMed ID: 3079839
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses.
    Ballyk PD; Walsh C; Butany J; Ojha M
    J Biomech; 1998 Mar; 31(3):229-37. PubMed ID: 9645537
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Unique performance characteristics of Novafil.
    Rodeheaver GT; Borzelleca DC; Thacker JG; Edlich RF
    Surg Gynecol Obstet; 1987 Mar; 164(3):230-6. PubMed ID: 3547720
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The role of suture material on healing of vascular anastomosis].
    Naoe A
    Nihon Geka Gakkai Zasshi; 1989 Jun; 90(6):941-8. PubMed ID: 2552281
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Vein and artery growth after anastomosis with vascular closure staple clips vs interrupted polypropylene suture: application in pediatric vascular surgery.
    Calles-Vázquez Mdel C; Viguera FJ; Sun F; Usón JM; Usón J
    J Pediatr Surg; 2005 Sep; 40(9):1428-35. PubMed ID: 16150344
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microvascular anastomoses in growing vessels: a long-term evaluation of nonabsorbable suture materials.
    Chen LE; Seaber AV; Urbaniak JR
    J Reconstr Microsurg; 1993 May; 9(3):183-9. PubMed ID: 8515396
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The protective effect of vein cuffed anastomoses is not mechanical in origin.
    Norberto JJ; Sidawy AN; Trad KS; Jones BA; Neville RF; Najjar SF; Sidawy MK; DePalma RG
    J Vasc Surg; 1995 Apr; 21(4):558-64; discussion 564-6. PubMed ID: 7707561
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rotational in vitro compliance measurement of diverse anastomotic configurations: a tool for anastomotic engineering.
    Knez P; Nelson K; Hakimi M; Al-Haidary J; Schneider C; Schmitz-Rixen T
    J Biomech; 2004 Mar; 37(3):275-80. PubMed ID: 14757445
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of suture technique on arterial anastomotic compliance.
    Klein SR; Goldberg L; Miranda RM; Bosco P; Nelson RJ; White RA
    Arch Surg; 1982 Jan; 117(1):45-7. PubMed ID: 7034672
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Presence of calcium in the vessel walls after end-to-end arterial anastomoses with polydioxanone and polypropylene sutures in growing dogs.
    Gersak B
    J Thorac Cardiovasc Surg; 1993 Oct; 106(4):587-91. PubMed ID: 8412250
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Absorbable suture improves growth of venous anastomoses.
    Gillinov AM; Lee AW; Redmond JM; Zehr KJ; Jackson L; Davis EA; Hruban RH; Williams GM; Cameron DE
    J Vasc Surg; 1992 Nov; 16(5):769-73. PubMed ID: 1433665
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.