These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 8231323)

  • 21. Hybrid microwave tomography technique for breast cancer imaging.
    Sabouni A; Flores-Tapia D; Noghanian S; Thomas G; Pistorius S
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():4273-6. PubMed ID: 17946617
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Microwave photonic radar with a fiber-distributed antenna array for three-dimensional imaging.
    Dong J; Zhang F; Jiao Z; Sun Q; Li W
    Opt Express; 2020 Jun; 28(13):19113-19125. PubMed ID: 32672195
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Adaptive Monostatic System for Measuring Microwave Reflections from the Breast.
    Bourqui J; Kuhlmann M; Kurrant DJ; Lavoie BR; Fear EC
    Sensors (Basel); 2018 Apr; 18(5):. PubMed ID: 29701677
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Microwave tomography: two-dimensional system for biological imaging.
    Semenov SY; Svenson RH; Boulyshev AE; Souvorov AE; Borisov VY; Sizov Y; Starostin AN; Dezern KR; Tatsis GP; Baranov VY
    IEEE Trans Biomed Eng; 1996 Sep; 43(9):869-77. PubMed ID: 9214802
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Design and implementation of an improved invasive antenna for microwave hyperthermia].
    Xue Q; Sun B; Chen L; Wang J
    Zhongguo Yi Liao Qi Xie Za Zhi; 2010 Nov; 34(6):427-30. PubMed ID: 21360981
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dynamic Microwave Imaging of the Cardiovascular System Using Ultra-Wideband Radar-on-Chip Devices.
    Lauteslager T; Tommer M; Lande TS; Constandinou TG
    IEEE Trans Biomed Eng; 2022 Sep; 69(9):2935-2946. PubMed ID: 35271437
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An attempt of microwave CT system which discriminates the transmission path by means of time domain measurement.
    Tamura M; Ogawa T; Miyakawa M
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():3938-41. PubMed ID: 22255201
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Electrical impedance tomography for thermal monitoring of hyperthermia treatment: an assessment using in vitro and in vivo measurements.
    Conway J
    Clin Phys Physiol Meas; 1987; 8 Suppl A():141-6. PubMed ID: 3568563
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Compound Radar Approach for Breast Imaging.
    Byrne D; Sarafianou M; Craddock IJ
    IEEE Trans Biomed Eng; 2017 Jan; 64(1):40-51. PubMed ID: 26955012
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Microwave thermoacoustic tomographic (MTT) imaging.
    Lin JC
    Phys Med Biol; 2021 May; 66(10):. PubMed ID: 33873175
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Super-resolution radar imaging for breast cancer detection with microwaves: the integrated information selection criteria.
    Fasoula A; Moloney BM; Duchesne L; Cano JDG; Oliveira BL; Bernard JG; Kerin MJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():1868-1874. PubMed ID: 31946262
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Performance of leading artifact removal algorithms assessed across microwave breast imaging prototype scan configurations.
    Elahi MA; Curtis C; Lavoie BR; Glavin M; Jones E; Fear E; O'Halloran M
    Comput Med Imaging Graph; 2017 Jun; 58():33-44. PubMed ID: 28342616
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Three-Dimensional Microwave Hyperthermia for Breast Cancer Treatment in a Realistic Environment Using Particle Swarm Optimization.
    Nguyen PT; Abbosh A; Crozier S
    IEEE Trans Biomed Eng; 2017 Jun; 64(6):1335-1344. PubMed ID: 28113219
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Ground Penetrating Radar Algorithm to Sense the Depth of Blood Clot in Microwave Head Imaging.
    Kandasamy L; J M
    Curr Med Imaging; 2022; 18(8):845-854. PubMed ID: 35034599
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Modeling the detectability of vesicoureteral reflux using microwave radiometry.
    Arunachalam K; Maccarini PF; De Luca V; Bardati F; Snow BW; Stauffer PR
    Phys Med Biol; 2010 Sep; 55(18):5417-35. PubMed ID: 20736499
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Three-dimensional microwave tomography: experimental prototype of the system and vector born reconstruction method.
    Semenov SY; Svenson RH; Bulyshev AE; Souvorov AE; Nazarov AG; Sizov YE; Pavlovsky AV; Borisov VY; Voinov BA; Simonova GI; Starostin AN; Posukh VG; Tatsis GP; Baranov VY
    IEEE Trans Biomed Eng; 1999 Aug; 46(8):937-46. PubMed ID: 10431458
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Microwave thermal imaging: initial in vivo experience with a single heating zone.
    Meaney PM; Fanning MW; Paulsen KD; Lit D; Pendergrass SA; Fang Q; Moodie KL
    Int J Hyperthermia; 2003; 19(6):617-41. PubMed ID: 14756452
    [TBL] [Abstract][Full Text] [Related]  

  • 38. High-Resolution and Large-Detection-Range Virtual Antenna Array for Automotive Radar Applications.
    Abdullah H; Mabrouk M; Abd-Elnaby Kabeel A; Hussein A
    Sensors (Basel); 2021 Mar; 21(5):. PubMed ID: 33801225
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An ultra-wideband microwave tomography system: preliminary results.
    Gilmore C; Mojabi P; Zakaria A; Ostadrahimi M; Kaye C; Noghanian S; Shafai L; Pistorius S; LoVetri J
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2288-91. PubMed ID: 19965168
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Quantitative microwave imaging with a 2.45-GHz planar microwave camera.
    Franchois A; Joisel A; Pichot C; Bolomey JC
    IEEE Trans Med Imaging; 1998 Aug; 17(4):550-61. PubMed ID: 9845311
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]