97 related articles for article (PubMed ID: 8233775)
1. The CAT-CAM socket and quadrilateral socket: a comparison of energy cost during ambulation.
Gailey RS; Lawrence D; Burditt C; Spyropoulos P; Newell C; Nash MS
Prosthet Orthot Int; 1993 Aug; 17(2):95-100. PubMed ID: 8233775
[TBL] [Abstract][Full Text] [Related]
2. Energy expenditure of trans-tibial amputees during ambulation at self-selected pace.
Gailey RS; Wenger MA; Raya M; Kirk N; Erbs K; Spyropoulos P; Nash MS
Prosthet Orthot Int; 1994 Aug; 18(2):84-91. PubMed ID: 7991365
[TBL] [Abstract][Full Text] [Related]
3. The effects of prosthesis mass on metabolic cost of ambulation in non-vascular trans-tibial amputees.
Gailey RS; Nash MS; Atchley TA; Zilmer RM; Moline-Little GR; Morris-Cresswell N; Siebert LI
Prosthet Orthot Int; 1997 Apr; 21(1):9-16. PubMed ID: 9141121
[TBL] [Abstract][Full Text] [Related]
4. A comparison of energy expenditure by a high level trans-femoral amputee using the Intelligent Prosthesis and conventionally damped prosthetic limbs.
Taylor MB; Clark E; Offord EA; Baxter C
Prosthet Orthot Int; 1996 Aug; 20(2):116-21. PubMed ID: 8876005
[TBL] [Abstract][Full Text] [Related]
5. Energy cost of walking: comparison of "intelligent prosthesis" with conventional mechanism.
Buckley JG; Spence WD; Solomonidis SE
Arch Phys Med Rehabil; 1997 Mar; 78(3):330-3. PubMed ID: 9084360
[TBL] [Abstract][Full Text] [Related]
6. Energy cost of walking in transfemoral amputees: Comparison between Marlo Anatomical Socket and Ischial Containment Socket.
Traballesi M; Delussu AS; Averna T; Pellegrini R; Paradisi F; Brunelli S
Gait Posture; 2011 Jun; 34(2):270-4. PubMed ID: 21684165
[TBL] [Abstract][Full Text] [Related]
7. Management of an above-knee amputee with complex medical problems using the CAT-CAM prosthesis.
Mitchell CA; Versluis TL
Phys Ther; 1990 Jun; 70(6):389-93. PubMed ID: 2345781
[TBL] [Abstract][Full Text] [Related]
8. Exercise performance of lower-extremity amputees.
Ward KH; Meyers MC
Sports Med; 1995 Oct; 20(4):207-14. PubMed ID: 8584846
[TBL] [Abstract][Full Text] [Related]
9. Energy expenditure of below-knee amputees during harness-supported treadmill ambulation.
Hunter D; Smith Cole E; Murray JM; Murray TD
J Orthop Sports Phys Ther; 1995 May; 21(5):268-76. PubMed ID: 7787850
[TBL] [Abstract][Full Text] [Related]
10. Carbohydrate and fat oxidation in persons with lower limb amputation during walking with different speeds.
Gjovaag T; Mirtaheri P; Starholm IM
Prosthet Orthot Int; 2018 Jun; 42(3):304-310. PubMed ID: 29119861
[TBL] [Abstract][Full Text] [Related]
11. Energy cost of walking of below-knee amputees having no vascular disease.
Pagliarulo MA; Waters R; Hislop HJ
Phys Ther; 1979 May; 59(5):538-43. PubMed ID: 441113
[TBL] [Abstract][Full Text] [Related]
12. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
Lee VS; Solomonidis SE; Spence WD
Proc Inst Mech Eng H; 1997; 211(2):167-80. PubMed ID: 9184457
[TBL] [Abstract][Full Text] [Related]
13. Energy costs & performance of transtibial amputees & non-amputees during walking & running.
Mengelkoch LJ; Kahle JT; Highsmith MJ
Int J Sports Med; 2014 Dec; 35(14):1223-8. PubMed ID: 25144429
[TBL] [Abstract][Full Text] [Related]
14. Silicone soft socket system: its effect on the rehabilitation of geriatric patients with transfemoral amputations.
Trieb K; Lang T; Stulnig T; Kickinger W
Arch Phys Med Rehabil; 1999 May; 80(5):522-5. PubMed ID: 10326914
[TBL] [Abstract][Full Text] [Related]
15. Physiological comparison of walking among bilateral above-knee amputee and able-bodied subjects, and a model to account for the differences in metabolic cost.
Hoffman MD; Sheldahl LM; Buley KJ; Sandford PR
Arch Phys Med Rehabil; 1997 Apr; 78(4):385-92. PubMed ID: 9111458
[TBL] [Abstract][Full Text] [Related]
16. Oxygen consumption of elderly persons with bilateral below knee amputations: ambulation vs wheelchair propulsion.
DuBow LL; Witt PL; Kadaba MP; Reyes R; Cochran V
Arch Phys Med Rehabil; 1983 Jun; 64(6):255-9. PubMed ID: 6860095
[TBL] [Abstract][Full Text] [Related]
17. Residual limb wounds or ulcers heal in transtibial amputees using an active suction socket system. A randomized controlled study.
Traballesi M; Delussu AS; Fusco A; Iosa M; Averna T; Pellegrini R; Brunelli S
Eur J Phys Rehabil Med; 2012 Dec; 48(4):613-23. PubMed ID: 22641248
[TBL] [Abstract][Full Text] [Related]
18. Oxygen consumption during ambulation: comparison of using a prosthesis fitted with and without a tele-torsion device.
Buckley JG; Jones SF; Birch KM
Arch Phys Med Rehabil; 2002 Apr; 83(4):576-80. PubMed ID: 11932866
[TBL] [Abstract][Full Text] [Related]
19. Comparison of different microprocessor controlled knee joints on the energy consumption during walking in trans-femoral amputees: intelligent knee prosthesis (IP) versus C-leg.
Chin T; Machida K; Sawamura S; Shiba R; Oyabu H; Nagakura Y; Takase I; Nakagawa A
Prosthet Orthot Int; 2006 Apr; 30(1):73-80. PubMed ID: 16739783
[TBL] [Abstract][Full Text] [Related]
20. The efficacy of physiological cost index (PCI) measurement of a subject walking with an Intelligent Prosthesis.
Chin T; Sawamura S; Fujita H; Nakajima S; Ojima I; Oyabu H; Nagakura Y; Otsuka H; Nakagawa A
Prosthet Orthot Int; 1999 Apr; 23(1):45-9. PubMed ID: 10355642
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]