These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 8234723)

  • 1. Bone contusions of the knee: increased lesion detection with fast spin-echo MR imaging with spectroscopic fat saturation.
    Kapelov SR; Teresi LM; Bradley WG; Bucciarelli NR; Murakami DM; Mullin WJ; Jordan JE
    Radiology; 1993 Dec; 189(3):901-4. PubMed ID: 8234723
    [TBL] [Abstract][Full Text] [Related]  

  • 2. MR diagnosis of bone contusions of the knee: comparison of coronal T2-weighted fast spin-echo with fat saturation and fast spin-echo STIR images with conventional STIR images.
    Arndt WF; Truax AL; Barnett FM; Simmons GE; Brown DC
    AJR Am J Roentgenol; 1996 Jan; 166(1):119-24. PubMed ID: 8571859
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic resonance imaging of musculoskeletal lesions: comparison of three fat-saturation pulse sequences.
    Pui MH; Goh PS; Choo HF; Fok EC
    Australas Radiol; 1997 May; 41(2):99-102. PubMed ID: 9153802
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Magnetic resonance in the identification and assessment of extent and severity of bone contusion damage: comparison of several types of imaging (SE/T1, GE/T2 and SE/T1) with fat suppression].
    Cappabianca S; Iscaro FM; Sirignano C; Napoli E; Del Vecchio W
    Radiol Med; 1998 Nov; 96(5):439-45. PubMed ID: 10051866
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Value of sagittal fat-suppressed proton-density fast-spin-echo of the knee joint as a limited protocol in evaluating internal knee derangements.
    Khoury NJ; Mahfoud Z; Masrouha KZ; Elkattah R; Assaad T; Abdallah A; Hourani MH
    J Comput Assist Tomogr; 2011; 35(5):653-61. PubMed ID: 21926865
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: comparison with arthroscopy in 130 patients.
    Bredella MA; Tirman PF; Peterfy CG; Zarlingo M; Feller JF; Bost FW; Belzer JP; Wischer TK; Genant HK
    AJR Am J Roentgenol; 1999 Apr; 172(4):1073-80. PubMed ID: 10587150
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of bone contusions with fat-saturated fast spin-echo proton-density magnetic resonance imaging.
    Lal NR; Jamadar DA; Doi K; Newman JS; Adler RS; Uri DS; Kazerooni EA
    Can Assoc Radiol J; 2000 Jun; 51(3):182-5. PubMed ID: 10914084
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of inversion recovery fast spin-echo (FSE) with T2-weighted fat-saturated FSE and T1-weighted MR imaging in bone marrow lesion detection.
    Pui MH; Chang SK
    Skeletal Radiol; 1996 Feb; 25(2):149-52. PubMed ID: 8848745
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MR imaging of bone marrow lesions: relative conspicuousness on T1-weighted, fat-suppressed T2-weighted, and STIR images.
    Mirowitz SA; Apicella P; Reinus WR; Hammerman AM
    AJR Am J Roentgenol; 1994 Jan; 162(1):215-21. PubMed ID: 8273669
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Coronal fat suppression fast spin echo images of the knee: evaluation of 202 patients with arthroscopic correlation.
    Kojima KY; Demlow TA; Szumowski J; Quinn SF
    Magn Reson Imaging; 1996; 14(9):1017-22. PubMed ID: 9070992
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Fast spin echo imaging of vertebral metastasis: comparison of fat suppression techniques (FSE-CHESS, STIR-FSE)].
    Scarabino T; Giannatempo GM; Popolizio T; Scarale MG; Cammisa M; Salvolini U
    Radiol Med; 1996 Sep; 92(3):180-5. PubMed ID: 8975299
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Squamous cell carcinoma of the oral cavity: MR findings and value of T1-versus T2-weighted fast spin-echo images.
    Yasumoto M; Shibuya H; Takeda M; Korenaga T
    AJR Am J Roentgenol; 1995 Apr; 164(4):981-7. PubMed ID: 7726062
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Comparison between pig lumbar zypapophyseal joint cartilage acquired from multiple magnetic resonance image sequences and gross specimens].
    Liao H; Yu W; Wang W; Liao Y
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2010 Oct; 35(10):1064-72. PubMed ID: 21051831
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Utility of breath-hold fast-recovery fast spin-echo t2 versus respiratory-triggered fast spin-echo T2 in clinical hepatic imaging.
    Huang J; Raman SS; Vuong N; Sayre JW; Lu DS
    AJR Am J Roentgenol; 2005 Mar; 184(3):842-6. PubMed ID: 15728606
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Synthetic-echo time postprocessing technique for generating images with variable T2-weighted contrast: diagnosis of meniscal and cartilage abnormalities of the knee.
    Andreisek G; White LM; Theodoropoulos JS; Naraghi A; Young N; Zhao CY; Mamisch TC; Sussman MS
    Radiology; 2010 Jan; 254(1):188-99. PubMed ID: 20032152
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Magnetic resonance imaging of articular cartilage of the knee: comparison between fat-suppressed three-dimensional SPGR imaging, fat-suppressed FSE imaging, and fat-suppressed three-dimensional DEFT imaging, and correlation with arthroscopy.
    Yoshioka H; Stevens K; Hargreaves BA; Steines D; Genovese M; Dillingham MF; Winalski CS; Lang P
    J Magn Reson Imaging; 2004 Nov; 20(5):857-64. PubMed ID: 15503323
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective comparison of T2-weighted fast spin-echo, with and without fat suppression, and conventional spin-echo pulse sequences in the upper abdomen.
    Schwartz LH; Seltzer SE; Tempany CM; Silverman SG; Piwnica-Worms DR; Adams DF; Herman L; Herman LT; Hooshmand R
    Radiology; 1993 Nov; 189(2):411-6. PubMed ID: 8210368
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of malignant biliary obstruction: efficacy of fast multiplanar spoiled gradient-recalled MR imaging vs spin-echo MR imaging, CT, and cholangiography.
    Low RN; Sigeti JS; Francis IR; Weinman D; Bower B; Shimakawa A; Foo TK
    AJR Am J Roentgenol; 1994 Feb; 162(2):315-23. PubMed ID: 8310918
    [TBL] [Abstract][Full Text] [Related]  

  • 19. MRI of acute bone bruises: timing of the appearance of findings in a swine model.
    Blankenbaker DG; De Smet AA; Vanderby R; McCabe RP; Koplin SA
    AJR Am J Roentgenol; 2008 Jan; 190(1):W1-7. PubMed ID: 18094266
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Usefulness of simultaneous acquisition of spatial harmonics technique for MRI of the knee.
    Magee T; Shapiro M; Williams D
    AJR Am J Roentgenol; 2004 Jun; 182(6):1411-5. PubMed ID: 15149984
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.