178 related articles for article (PubMed ID: 8237280)
1. [Continuous measurement of mixed venous oxygen saturation].
Hannemann L; Reinhart K
Acta Med Austriaca; 1993; 20(4):107-11. PubMed ID: 8237280
[TBL] [Abstract][Full Text] [Related]
2. [Monitoring of oxygen transport systems].
Reinhart K
Anaesthesist; 1988 Jan; 37(1):1-9. PubMed ID: 3281505
[TBL] [Abstract][Full Text] [Related]
3. Oxygen kinetics in experimental sepsis.
Hirschl RB; Heiss KF; Cilley RE; Hultquist KA; Housner J; Bartlett RH
Surgery; 1992 Jul; 112(1):37-44. PubMed ID: 1621225
[TBL] [Abstract][Full Text] [Related]
4. [The meaningfulness of central venous blood samples. Central venous versus mixed venous O2 status].
Brandt L; Mertzlufft F
Anaesthesist; 1991 Mar; 40(3):131-44. PubMed ID: 2035819
[TBL] [Abstract][Full Text] [Related]
5. Feasibility of continuous oxygen delivery and cardiac output measurement by application of the Fick principle.
Feustel PJ; Perkins RJ; Oppenlander JE; Stratton HH; Cohen IL
Am J Respir Crit Care Med; 1994 Mar; 149(3 Pt 1):751-8. PubMed ID: 8118646
[TBL] [Abstract][Full Text] [Related]
6. Inclusion of oxygen consumption improves the accuracy of arterial and venous oxygen saturation interpretation after the Norwood procedure.
Li J; Zhang G; Holtby HM; McCrindle BW; Cai S; Humpl T; Caldarone CA; Williams WG; Redington AN; Van Arsdell GS
J Thorac Cardiovasc Surg; 2006 May; 131(5):1099-107. PubMed ID: 16678596
[TBL] [Abstract][Full Text] [Related]
7. [Does mixed venous desaturation during a bed bath indicate cardiopulmonary decompensation in postoperative cardiac patients?].
Hayashida M; Ogawa K; Kawashima Y; Isoda R; Sato M; Fujimura C; Yoneyama T; Sawamura S
Masui; 1998 Aug; 47(8):933-8. PubMed ID: 9753957
[TBL] [Abstract][Full Text] [Related]
8. Profiles of hemodynamics and oxygen transport derived by using continuous measured oxygen consumption after the Norwood procedure.
Li J; Zhang G; McCrindle BW; Holtby H; Humpl T; Cai S; Caldarone CA; Redington AN; Van Arsdell GS
J Thorac Cardiovasc Surg; 2007 Feb; 133(2):441-8. PubMed ID: 17258581
[TBL] [Abstract][Full Text] [Related]
9. [The role of mixed venous oxygen saturation in perioperative monitoring and therapy. A critical stock taking].
Wiesemes R; Peters J
Anasthesiol Intensivmed Notfallmed Schmerzther; 1993 Aug; 28(5):269-78. PubMed ID: 8373972
[TBL] [Abstract][Full Text] [Related]
10. Clinical implications of intraoperative continuous mixed venous oxygen saturation monitoring.
Naruns EB
AANA J; 1989 Feb; 57(1):45-52. PubMed ID: 2929243
[TBL] [Abstract][Full Text] [Related]
11. Clinical use of continuous monitoring of mixed venous oxygen saturation during and after cardiovascular surgery.
Baele P; Goenen M; Kestens-Servaye Y
Acta Anaesthesiol Belg; 1985 Mar; 36(1):5-13. PubMed ID: 4013634
[TBL] [Abstract][Full Text] [Related]
12. Continuous monitoring of mixed venous oxygen saturation during aortofemoral bypass grafting.
Norwood SH; Nelson LD
Am Surg; 1986 Feb; 52(2):114-5. PubMed ID: 3946935
[TBL] [Abstract][Full Text] [Related]
13. Oxygen transportation in the blood.
Jalonen J
Ann Clin Res; 1981; 13 Suppl 33():39-43. PubMed ID: 7342842
[TBL] [Abstract][Full Text] [Related]
14. [Hepatic venous and mixed venous O2 saturation during catecholamine therapy in patients with septic shock].
Meier-Hellmann A; Hannemann L; Specht M; Spies C; Reinhart K
Anaesthesist; 1993 Jan; 42(1):29-33. PubMed ID: 8447569
[TBL] [Abstract][Full Text] [Related]
15. Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof.
Jubran A; Mathru M; Dries D; Tobin MJ
Am J Respir Crit Care Med; 1998 Dec; 158(6):1763-9. PubMed ID: 9847265
[TBL] [Abstract][Full Text] [Related]
16. Physiologic rationale of Sv-O2 monitoring.
Mims BC
Crit Care Nurs Clin North Am; 1989 Sep; 1(3):619-28. PubMed ID: 2684246
[TBL] [Abstract][Full Text] [Related]
17. [Cardiopulmonary effects of CPPV (continuous positive pressure ventilation) and IRV (inverse ratio ventilation) in experimental myocardial ischemia].
Hachenberg T; Meyer J; Sielenkämper A; Kraft W; Vogt B; Breithardt G; Lawin P
Anaesthesist; 1993 Apr; 42(4):210-20. PubMed ID: 8488992
[TBL] [Abstract][Full Text] [Related]
18. Overcoming right ventricular failure with left ventricular assist devices.
Santamore WP; Austin EH; Gray L
J Heart Lung Transplant; 1997 Nov; 16(11):1122-8. PubMed ID: 9402511
[TBL] [Abstract][Full Text] [Related]
19. The effect of norepinephrine infusion on oxygen delivery and consumption in the canine model.
Boorstein SM; Hirschl RB; Riley MK; Kahan BS; Hultquist KA; Bartlett RH
J Surg Res; 1994 Mar; 56(3):251-5. PubMed ID: 8145542
[TBL] [Abstract][Full Text] [Related]
20. [Changes of tissue oxygenation and relationship between oxygen delivery and consumption in patients with poor cardiac function undergoing valve replacement].
Liu L; Zhou J; Chen Q
Hunan Yi Ke Da Xue Xue Bao; 1998; 23(3):272-4. PubMed ID: 10681757
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]