These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 8240478)

  • 1. Overestimation of neonatal PO2 by collection of arterial blood gas values with the butterfly infusion set.
    Thelin OP; Karanth S; Pourcyrous M; Cooke RJ
    J Perinatol; 1993; 13(1):65-7. PubMed ID: 8240478
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Overestimation of neonatal PO2 by collection of arterial blood gas values with the butterfly infusion set.
    Kim EH; Cohen RS; Ramachandran P; Glasscock GF
    J Perinatol; 1993; 13(3):255. PubMed ID: 8345393
    [No Abstract]   [Full Text] [Related]  

  • 3. Evaluation of arterial blood sampling using the B 109 syringe (radiometer).
    Fassoulaki A; Athanassiou E
    Acta Anaesthesiol Belg; 1986; 37(4):271-3. PubMed ID: 3105223
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Aerobic blood sampling technique using the B 109-syringe (author's transl)].
    Andersen LH; Thomsen A
    Anaesthesist; 1978 Mar; 27(3):143-4. PubMed ID: 25595
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effects of time on pH and gas values in the blood contained in the umbilical cord.
    Valenzuela P; Guijarro R
    Acta Obstet Gynecol Scand; 2006; 85(11):1307-9. PubMed ID: 17091408
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Arterial blood gas sampling using a modified standard plastic syringe.
    Campbell JH; Carter R; Milroy R; Campbell LA; Banham SW
    Br J Clin Pract; 1990 Mar; 44(3):96-7. PubMed ID: 2111713
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical validation of a continuous intravascular neonatal blood gas sensor introduced through an umbilical artery catheter.
    Meyers PA; Worwa C; Trusty R; Mammel MC
    Respir Care; 2002 Jun; 47(6):682-7. PubMed ID: 12036438
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous blood gas monitoring using an in-dwelling optode method: comparison to intermittent arterial blood gas sampling in ECMO patients.
    Rais-Bahrami K; Rivera O; Mikesell GT; Short BL
    J Perinatol; 2002 Sep; 22(6):472-4. PubMed ID: 12168125
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validity of scalp blood sampling. Comparison of scalp and arterial blood in the newborn.
    Stephens SR; Clark RB; Beard AG; Brown WE
    Am J Obstet Gynecol; 1969 Oct; 105(4):616-9. PubMed ID: 5824883
    [No Abstract]   [Full Text] [Related]  

  • 10. Validation of a new arterial micro sampling device.
    Cohill JD; White FK
    Respir Care; 1982 Oct; 27(10):1210-4. PubMed ID: 10315312
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculation in the 100% oxygen test.
    Smeenk FW; Janssen JD; Arends BJ; Harff GA; van den Bosch JA; Schönberger JP; Postmus PE
    Eur Respir J; 1997 Apr; 10(4):910-3. PubMed ID: 9150334
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Placental compared with umbilical cord blood to assess fetal blood gas and acid-base status.
    Nodwell A; Carmichael L; Ross M; Richardson B
    Obstet Gynecol; 2005 Jan; 105(1):129-38. PubMed ID: 15625154
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Continuous blood gas monitoring using an in-dwelling optode method: clinical evaluation of the Neotrend sensor using a luer stub adaptor to access the umbilical artery catheter.
    Rais-Bahrami K; Rivera O; Mikesell GT; Short BL
    J Perinatol; 2002; 22(5):367-9. PubMed ID: 12082470
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a method for converting venous values of acid-base and oxygenation status to arterial values.
    Toftegaard M; Rees SE; Andreassen S
    Emerg Med J; 2009 Apr; 26(4):268-72. PubMed ID: 19307387
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of syringe material and needle size on the minimum plunger-displacement pressure of arterial blood gas syringes.
    Ansel GM; Douce FH
    Respir Care; 1982 Feb; 27(2):147-51. PubMed ID: 10315159
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Neonatal transcutaneous arterial oxygen saturation monitoring.
    Lewallen PK; Mammel MC; Coleman JM; Boros SJ
    J Perinatol; 1987; 7(1):8-10. PubMed ID: 3507551
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accurate micromethod of neonatal blood sampling from peripheral arterial catheters.
    Thorkelsson T; Hoath SB
    J Perinatol; 1995; 15(1):43-6. PubMed ID: 7650553
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Capillary plasma ammonia concentration in neonates receiving total parenteral nutrition. Comparison with arterial and venous concentrations.
    Schwartz JB; Cheng MH; Ramos AD; Merritt RJ; Platzker AC
    J Perinatol; 1990 Dec; 10(4):376-9. PubMed ID: 2126032
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The clinical utility of arterialized earlobe capillary blood in the assessment of patients for long-term oxygen therapy.
    Eaton T; Rudkin S; Garrett JE
    Respir Med; 2001 Aug; 95(8):655-60. PubMed ID: 11530953
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Umbilical cord blood acid-base values in uncomplicated term vaginal breech deliveries.
    Daniel Y; Fait G; Lessing JB; Jaffa A; Gull I; Shenav M; Peyser MR; Kupferminc MJ
    Acta Obstet Gynecol Scand; 1998 Feb; 77(2):182-5. PubMed ID: 9512324
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.