155 related articles for article (PubMed ID: 8240478)
1. Overestimation of neonatal PO2 by collection of arterial blood gas values with the butterfly infusion set. Thelin OP; Karanth S; Pourcyrous M; Cooke RJ J Perinatol; 1993; 13(1):65-7. PubMed ID: 8240478 [TBL] [Abstract][Full Text] [Related]
2. Overestimation of neonatal PO2 by collection of arterial blood gas values with the butterfly infusion set. Kim EH; Cohen RS; Ramachandran P; Glasscock GF J Perinatol; 1993; 13(3):255. PubMed ID: 8345393 [No Abstract] [Full Text] [Related]
3. Evaluation of arterial blood sampling using the B 109 syringe (radiometer). Fassoulaki A; Athanassiou E Acta Anaesthesiol Belg; 1986; 37(4):271-3. PubMed ID: 3105223 [TBL] [Abstract][Full Text] [Related]
4. [Aerobic blood sampling technique using the B 109-syringe (author's transl)]. Andersen LH; Thomsen A Anaesthesist; 1978 Mar; 27(3):143-4. PubMed ID: 25595 [TBL] [Abstract][Full Text] [Related]
5. The effects of time on pH and gas values in the blood contained in the umbilical cord. Valenzuela P; Guijarro R Acta Obstet Gynecol Scand; 2006; 85(11):1307-9. PubMed ID: 17091408 [TBL] [Abstract][Full Text] [Related]
6. Arterial blood gas sampling using a modified standard plastic syringe. Campbell JH; Carter R; Milroy R; Campbell LA; Banham SW Br J Clin Pract; 1990 Mar; 44(3):96-7. PubMed ID: 2111713 [TBL] [Abstract][Full Text] [Related]
7. Clinical validation of a continuous intravascular neonatal blood gas sensor introduced through an umbilical artery catheter. Meyers PA; Worwa C; Trusty R; Mammel MC Respir Care; 2002 Jun; 47(6):682-7. PubMed ID: 12036438 [TBL] [Abstract][Full Text] [Related]
8. Continuous blood gas monitoring using an in-dwelling optode method: comparison to intermittent arterial blood gas sampling in ECMO patients. Rais-Bahrami K; Rivera O; Mikesell GT; Short BL J Perinatol; 2002 Sep; 22(6):472-4. PubMed ID: 12168125 [TBL] [Abstract][Full Text] [Related]
9. Validity of scalp blood sampling. Comparison of scalp and arterial blood in the newborn. Stephens SR; Clark RB; Beard AG; Brown WE Am J Obstet Gynecol; 1969 Oct; 105(4):616-9. PubMed ID: 5824883 [No Abstract] [Full Text] [Related]
10. Validation of a new arterial micro sampling device. Cohill JD; White FK Respir Care; 1982 Oct; 27(10):1210-4. PubMed ID: 10315312 [TBL] [Abstract][Full Text] [Related]
11. Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculation in the 100% oxygen test. Smeenk FW; Janssen JD; Arends BJ; Harff GA; van den Bosch JA; Schönberger JP; Postmus PE Eur Respir J; 1997 Apr; 10(4):910-3. PubMed ID: 9150334 [TBL] [Abstract][Full Text] [Related]
12. Placental compared with umbilical cord blood to assess fetal blood gas and acid-base status. Nodwell A; Carmichael L; Ross M; Richardson B Obstet Gynecol; 2005 Jan; 105(1):129-38. PubMed ID: 15625154 [TBL] [Abstract][Full Text] [Related]
13. Continuous blood gas monitoring using an in-dwelling optode method: clinical evaluation of the Neotrend sensor using a luer stub adaptor to access the umbilical artery catheter. Rais-Bahrami K; Rivera O; Mikesell GT; Short BL J Perinatol; 2002; 22(5):367-9. PubMed ID: 12082470 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of a method for converting venous values of acid-base and oxygenation status to arterial values. Toftegaard M; Rees SE; Andreassen S Emerg Med J; 2009 Apr; 26(4):268-72. PubMed ID: 19307387 [TBL] [Abstract][Full Text] [Related]
15. Effects of syringe material and needle size on the minimum plunger-displacement pressure of arterial blood gas syringes. Ansel GM; Douce FH Respir Care; 1982 Feb; 27(2):147-51. PubMed ID: 10315159 [TBL] [Abstract][Full Text] [Related]