These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 8242171)

  • 21. Three-dimensional finite element analysis of the retention of fixed partial dentures.
    Augereau D; Renault P; Pierrisnard L; Barquins M
    Clin Oral Investig; 1997 Sep; 1(3):141-6. PubMed ID: 9612154
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Stress distribution of inlay-anchored adhesive fixed partial dentures: a finite element analysis of the influence of restorative materials and abutment preparation design.
    Magne P; Perakis N; Belser UC; Krejci I
    J Prosthet Dent; 2002 May; 87(5):516-27. PubMed ID: 12070515
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The effect of connector design on cement retention in an implant and natural tooth-supported fixed partial denture.
    Mathews MF; Breeding LC; Dixon DL; Aquilino SA
    J Prosthet Dent; 1991 Jun; 65(6):822-7. PubMed ID: 2072329
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Nonlinear finite element analysis of a splinted implant with various connectors and occlusal forces.
    Lin CL; Wang JC
    Int J Oral Maxillofac Implants; 2003; 18(3):331-40. PubMed ID: 12814307
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Retrospective evaluation of complete-arch fixed partial dentures connecting teeth and implant abutments in patients with normal and reduced periodontal support.
    Cordaro L; Ercoli C; Rossini C; Torsello F; Feng C
    J Prosthet Dent; 2005 Oct; 94(4):313-20. PubMed ID: 16198167
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Biomechanical concerns with fixed partial dentures involving implants.
    English CE
    Implant Dent; 1993; 2(4):221-42. PubMed ID: 8004049
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Study on the stress distribution of different superstructures for tooth-implant supported denture].
    Chen Y; Han DW; Xu QH
    Shanghai Kou Qiang Yi Xue; 2006 Apr; 15(2):206-9. PubMed ID: 16685368
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biomechanical comparison of two different collar structured implants supporting 3-unit fixed partial denture: a 3-D FEM study.
    Meriç G; Erkmen E; Kurt A; Eser A; Ozden AU
    Acta Odontol Scand; 2012 Jan; 70(1):61-71. PubMed ID: 21732740
    [TBL] [Abstract][Full Text] [Related]  

  • 29. FEA of Peri-Implant Stresses in Fixed Partial Denture Prostheses with Cantilevers.
    Alencar SM; Nogueira LB; Leal de Moura W; Rubo JH; Saymo de Oliveira Silva T; Martins GA; Moura CD
    J Prosthodont; 2017 Feb; 26(2):150-155. PubMed ID: 26588042
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone.
    Iplikçioğlu H; Akça K
    J Dent; 2002 Jan; 30(1):41-6. PubMed ID: 11741734
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Stress analysis of a fixed implant-supported denture by the finite element method (FEM) when varying the number of teeth used as abutments.
    Lanza MD; Seraidarian PI; Jansen WC; Lanza MD
    J Appl Oral Sci; 2011; 19(6):655-61. PubMed ID: 22231003
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Three-Dimensional Finite Element Analysis of the Biomechanical Behaviors of Implants with Different Connections, Lengths, and Diameters Placed in the Maxillary Anterior Region.
    Borie E; Orsi IA; Noritomi PY; Kemmoku DT
    Int J Oral Maxillofac Implants; 2016; 31(1):101-10. PubMed ID: 26478969
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Analysis of stress on a fixed partial denture with a blade-vent implant abutment.
    Takahashi N; Kitagami T; Komori T
    J Prosthet Dent; 1978 Aug; 40(2):186-91. PubMed ID: 357711
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of stress patterns produced by implant-retained overdentures and implant-retained fixed partial denture.
    Mazaro JV; Filho HG; Vedovatto E; Pellizzer EP; Rezende MC; Zavanelli AC
    J Craniofac Surg; 2011 Nov; 22(6):2153-7. PubMed ID: 22067869
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone.
    Quaresma SE; Cury PR; Sendyk WR; Sendyk C
    J Oral Implantol; 2008; 34(1):1-6. PubMed ID: 18390236
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Influence of the connector and implant design on the implant-tooth-connected prostheses.
    Da Silva EF; Pellizzer EP; Quinelli Mazaro JV; Garcia Júnior IR
    Clin Implant Dent Relat Res; 2010 Sep; 12(3):254-62. PubMed ID: 19438943
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Three-dimensional finite element analysis of fixed complete-arch prostheses supported by 4 immediate-loaded implants in the completely edentulous maxilla using clinical computerized tomography data.
    Kimura K; Fukase Y; Makino M; Masaki C; Nakamoto T; Hosokawa R
    J Oral Implantol; 2011 Mar; 37 Spec No():96-105. PubMed ID: 21495797
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Microstrain around dental implants supporting fixed partial prostheses under axial and non-axial loading conditions, in vitro strain gauge analysis.
    de Vasconcellos LG; Nishioka RS; de Vasconcellos LM; Balducci I; Kojima AN
    J Craniofac Surg; 2013 Nov; 24(6):e546-51. PubMed ID: 24220463
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Three-dimensional finite element stress analysis of a cantilever fixed partial denture.
    Awadalla HA; Azarbal M; Ismail YH; el-Ibiari W
    J Prosthet Dent; 1992 Aug; 68(2):243-8. PubMed ID: 1501167
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Biomechanical evaluation of screw- and cement-retained implant-supported prostheses: a nonlinear finite element analysis.
    Silva GC; Cornacchia TM; de Magalhães CS; Bueno AC; Moreira AN
    J Prosthet Dent; 2014 Dec; 112(6):1479-88. PubMed ID: 25062583
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.