These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 8244431)

  • 1. Mechanics of the occlusive arm cuff and its application as a volume sensor.
    Drzewiecki G; Bansal V; Karam E; Hood R; Apple H
    IEEE Trans Biomed Eng; 1993 Jul; 40(7):704-8. PubMed ID: 8244431
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement.
    Ursino M; Cristalli C
    IEEE Trans Biomed Eng; 1996 Aug; 43(8):761-78. PubMed ID: 9216149
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients.
    Bur A; Herkner H; Vlcek M; Woisetschläger C; Derhaschnig U; Delle Karth G; Laggner AN; Hirschl MM
    Crit Care Med; 2003 Mar; 31(3):793-9. PubMed ID: 12626986
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new oscillometry-based method for estimating the brachial arterial compliance under loaded conditions.
    Liu SH; Wang JJ; Huang KS
    IEEE Trans Biomed Eng; 2008 Oct; 55(10):2463-70. PubMed ID: 18838372
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Suitable location and optimum bladder width for the occluding cuff used for indirect arterial blood pressure measurements at the wrist.
    Lu W; Tsukada A; Kawarada A; Sasaki K
    Front Med Biol Eng; 1999; 9(1):9-29. PubMed ID: 10354907
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of urethral compliance on the steady state p-Q relationships assessed with a mechanical analog of the male lower urinary tract.
    Mijailovich SM; Sullivan MP; Yalla SV; Venegas JG
    Neurourol Urodyn; 2007; 26(2):234-46. PubMed ID: 17039462
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Laboratory evaluation of 4 brands of endotracheal tube cuff inflator.
    Blanch PB
    Respir Care; 2004 Feb; 49(2):166-73. PubMed ID: 14744266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Loose cuff hypertension.
    Taleyarkhan PR; Geddes LA; Kemeny AE; Vitter JS
    Cardiovasc Eng; 2009 Sep; 9(3):113-8. PubMed ID: 19662531
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Noninvasive, continuous measurement of finger artery pressure with the servo-plethysmo-manometer Finapres].
    Hartmann B; Bassenge E
    Herz; 1989 Aug; 14(4):251-9. PubMed ID: 2676814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of external pressure on arteries distal to the cuff during sphygmomanometry.
    Nitzan M; Rosenfeld C; Weiss AT; Grossman E; Patron A; Murray A
    IEEE Trans Biomed Eng; 2005 Jun; 52(6):1120-7. PubMed ID: 15977741
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An optical oscillometric method for neonatal and premature infant blood pressure monitoring.
    Roeder RA; Geddes LA
    Adv Neonatal Care; 2009 Apr; 9(2):77-81. PubMed ID: 19363328
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Blood pressure measurements using three different cuff sizes].
    Berntsen R; Rømo O; Nielsen EW
    Tidsskr Nor Laegeforen; 1998 Aug; 118(20):3112-5. PubMed ID: 9760852
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Can an intermittent pneumatic compression system monitor venous filling in the leg?
    Diamantopoulos I; Lever MJ
    J Med Eng Technol; 2008; 32(3):221-7. PubMed ID: 18432470
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Devices for blood pressure self measurement: tested in comparison.
    Anlauf M; Tholl U; Högermeyer D; Hirche H; Roggenbuck U; Simonides R
    Z Kardiol; 1996; 85 Suppl 3():20-5. PubMed ID: 8896295
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A continuous and non-invasive arterial pressure monitoring system in dialysis patients.
    Mambelli E; Mancini E; Santoro A
    Nephron Clin Pract; 2007; 107(4):c170-6. PubMed ID: 17975324
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of arterial compliance in vivo.
    Wiinberg N
    Stud Health Technol Inform; 2000; 71():99-108. PubMed ID: 10977606
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Theory of the oscillometric maximum and the systolic and diastolic detection ratios.
    Drzewiecki G; Hood R; Apple H
    Ann Biomed Eng; 1994; 22(1):88-96. PubMed ID: 8060030
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reactive rise in blood pressure upon cuff inflation: cuff inflation at the arm causes a greater rise in pressure than at the wrist in hypertensive patients.
    Charmoy A; Würzner G; Ruffieux C; Hasler C; Cachat F; Waeber B; Burnier M
    Blood Press Monit; 2007 Oct; 12(5):275-80. PubMed ID: 17890965
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of the OMRON M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension.
    El Feghali RN; Topouchian JA; Pannier BM; El Assaad HA; Asmar RG;
    Blood Press Monit; 2007 Jun; 12(3):173-8. PubMed ID: 17496467
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The transient relationship between pressure and volume in the pediatric pulmonary system.
    Kent RW; Woods WA; Salzar RS; Damon AM; Bass CR
    J Biomech; 2009 Aug; 42(11):1656-63. PubMed ID: 19497574
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.