194 related articles for article (PubMed ID: 8249909)
1. A parallel evaluation of four automated hematology analyzers.
Bentley SA; Johnson A; Bishop CA
Am J Clin Pathol; 1993 Dec; 100(6):626-32. PubMed ID: 8249909
[TBL] [Abstract][Full Text] [Related]
2. Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.
Thalhammer-Scherrer R; Knöbl P; Korninger L; Schwarzinger I
Arch Pathol Lab Med; 1997 Jun; 121(6):573-7. PubMed ID: 9199621
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of a total hematology analysis system (Sysmex HS-430). Benefits for large laboratories by reducing manual work load and optimizing screening efficacy for pathologic samples.
Födinger M; Speiser W; Karabentcheva S; Scherrer R; Veitl M; Schwarzinger I
Am J Clin Pathol; 1995 Nov; 104(5):503-9. PubMed ID: 7572809
[TBL] [Abstract][Full Text] [Related]
4. Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750, and Sysmex XE-2100, in terms of clinical usefulness.
Kang SH; Kim HK; Ham CK; Lee DS; Cho HI
Int J Lab Hematol; 2008 Dec; 30(6):480-6. PubMed ID: 19062362
[TBL] [Abstract][Full Text] [Related]
5. Sysmex SE-9000 hematology analyzer: performance evaluation on leukocyte differential counts using an NCCLS H20-A protocol. National Committee for Clinical Laboratory Standards.
Buttarello M; Bulian P; Temporin V; Rizzotti P
Am J Clin Pathol; 1997 Dec; 108(6):674-86. PubMed ID: 9384450
[TBL] [Abstract][Full Text] [Related]
6. A Comparison of Mindray BC-6800, Sysmex XN-2000, and Beckman Coulter LH750 Automated Hematology Analyzers: A Pediatric Study.
Ciepiela O; Kotuła I; Kierat S; Sieczkowska S; Podsiadłowska A; Jenczelewska A; Księżarczyk K; Demkow U
J Clin Lab Anal; 2016 Nov; 30(6):1128-1134. PubMed ID: 27184780
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of the ABX Cobas Vega automated hematology analyzer and comparison with the Coulter STKS.
Ferrero-Vacher C; Sudaka I; Jambou D; Vanhaeke D; Fischer F; Bayle J
Hematol Cell Ther; 1997 Jun; 39(3):149-58. PubMed ID: 9262992
[TBL] [Abstract][Full Text] [Related]
8. Flow-cytochemical differential leukocyte analysis with quantitation of neutrophil left shift. An evaluation of the Cobas-Helios analyzer.
Bentley SA; Johnson TS; Sohier CH; Bishop CA
Am J Clin Pathol; 1994 Aug; 102(2):223-30. PubMed ID: 8042593
[TBL] [Abstract][Full Text] [Related]
9. Miles Technicon H.2 automated hematology analyzer.
Health Devices; 1992 Nov; 21(11):387-419. PubMed ID: 1428895
[TBL] [Abstract][Full Text] [Related]
10. [Analytical evaluation of an automated hematologic analyzer: Cell Dyn 3500].
Sanzari M; De Toni S; D'Osualdo A; Floriani F; Plebani M
Minerva Med; 1996 Mar; 87(3):123-30. PubMed ID: 8668289
[TBL] [Abstract][Full Text] [Related]
11. [Comparative and simultaneous evaluation of three automated counters in hematology: Coulter STKS, Sysmex NE 8000, Technicon H-2].
Cart-Lamy P; Pernod G; Pirraud M; Drevait JM; Caillat D; Polack B; Kolodié L
Ann Biol Clin (Paris); 1993; 51(6):627-35. PubMed ID: 8172402
[TBL] [Abstract][Full Text] [Related]
12. Performance Evaluation of the Mindray BC 6800 Hematology Analyzer and Flag Comparison with the XE-2100 and Manual Microscopy.
Xiang D; Yue J; Sha C; Ren S; Li M; Wang C
Clin Lab; 2019 Apr; 65(4):. PubMed ID: 30969092
[TBL] [Abstract][Full Text] [Related]
13. An evaluation of leucocyte analysis on the Coulter STKS.
Robertson EP; Lai HW; Wei DC
Clin Lab Haematol; 1992; 14(1):53-68. PubMed ID: 1600694
[TBL] [Abstract][Full Text] [Related]
14. Complete analytical and diagnostic performances of the Abbott Cell Dyn 3500.
Sanzari M; De Toni S; D'Osualdo A; Rossetti M; Floriani F; Plebani M
Panminerva Med; 1998 Jun; 40(2):116-25. PubMed ID: 9689832
[TBL] [Abstract][Full Text] [Related]
15. Diagnostic performance: a comparative study of the leukocyte differential count on four automated haematology analysers.
Buttarello M; Lorenz C; Gadotti M; Toffalori E; Valentini A; Rizzotti P
Eur J Clin Chem Clin Biochem; 1993 Apr; 31(4):251-8. PubMed ID: 8318574
[TBL] [Abstract][Full Text] [Related]
16. Preliminary evaluation of the new hematology analyzer COULTER GEN-S in a university hospital.
Picard F; Gicquel C; Marnet L; Guesnu M; Levy JP
Clin Chem Lab Med; 1999 Jun; 37(6):681-6. PubMed ID: 10475078
[TBL] [Abstract][Full Text] [Related]
17. The new hematology analyzer Sysmex XE-2100: performance evaluation of a novel white blood cell differential technology.
Ruzicka K; Veitl M; Thalhammer-Scherrer R; Schwarzinger I
Arch Pathol Lab Med; 2001 Mar; 125(3):391-6. PubMed ID: 11231489
[TBL] [Abstract][Full Text] [Related]
18. [Evaluation of the reproducibility of automated monocyte counting using flow cytometry and monoclonal antibodies].
Vives Corrons JL; Besson I; Villamor N; Aymerich M; Marín JL; Jou JM
Sangre (Barc); 1994 Jun; 39(3):197-201. PubMed ID: 7940050
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of the Abbott Cell-DYN 3500 hematology analyzer in university hospital.
Vives-Corrons JL; Besson I; Jou JM; Gutierrez G
Am J Clin Pathol; 1996 May; 105(5):553-9. PubMed ID: 8623762
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of the Sysmex NE-8000. Automated hematology analyzer in a high-volume outpatient laboratory.
Brigden ML; Page NE; Graydon C
Am J Clin Pathol; 1993 Dec; 100(6):618-25. PubMed ID: 8249908
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]